• Dam2e-400m Electronic MCCB

Dam2e-400m Electronic MCCB

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Installation: Fixed
Structure: MCCB
Poles Number: 3
Samples:
US$ 90/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Shanghai, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)

Basic Info.

Model NO.
DAM2E-400M
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
HS Code
85362000
Production Capacity
10000PCS/Month

Product Description

Application

DAM2 (CM1) series the rated insulation voltage of the circuit breaker is 800V,it is suitable for the distribution network of AC 50Hz / 60Hz, rated working voltage of 690V and rated current of 1250A, to distribute power and protect circuit and power equipment from being damaged caused by overload , short-circuit, under-voltage and other fault. Also for protection infrequent conversion of the circuits and infrequent start of motor and overload, short circuit, under voltage. DAM2 circuit breaker can be mounted vertically (upright) or horizontally (transverse). DAM2 MCCB is suitable for isolation and the symbol is " ". DAM2 MCCB meets the standard: IEC60947-2 "low-voltage switchgear and control equipment, Part 2: circuit breakers."

Normal operating conditions

1.Ambient air temperature: -5ºC~+40ºC, and average temperature in 24h is below +35ºC.
2.Altitude: The altitude of the installation site is not more than 2000m.
3.Atmospheric conditions: The air relative humidity in the highest temperature +40ºC is not more than 50%; In the low temperature can have higher relative humidity. The maximum average relative humidity is 90%, while the average monthly minimum temperature is +25ºC, and consider the temperature changes in product on the surface of the gel.
4.Pollution Degree: 3.

Selection of instructions

According to the pole, it classifies four types:
Type A: N-pole without over-current release components, and N-pole has been connected all along, and does not act with other three poles to turn on or off;
B-type: N-pole without over-current release components, and N-pole could act with other three poles (N-pole turn-on prior to turn-off);
Type C: N-pole fixed with over-current release components, and N-pole could act with other three poles (N-pole turn-on prior to turn-off);

Classification according to rated current of over-current release:
DAM2-63 MCCB has nine: 6,10,16,20,25,32,40,50,63 A;
DAM2-100 MCCB has nine: 16,20,25,32,40,50,63,80,100 A;
DAM2-250 MCCB has seven: 100,125,140,160,180,200,225 ,250A;
DAM2-400 MCCB has five: 225,250,315,350,400 A;
DAM2-630 MCCB has three: 400,500,630 A;
DAM2-800 MCCB has three: 630,700,800A;
DAM2-1250 MCCB has three: 800,1000,1250A.
Remark: 6A only has electromagnetic (instantaneous) type, is not recommended specifications.
According to the wiring method: wiring in front of board, wiring on back of board, insertion type of the board.
According to over-current release pattern: thermodynamic-electromagnetic (double) type, electromagnetic (instantaneous) type.
According to the outfit, it has two types: with or without outfit.
The outfit include inner accessories and outside accessories: The inner accessories have shunt release, under-voltage release, auxiliary contact and alarm contact. The outside accessories are turning handle operation mechanism, power-driven operation mechanism and so on.
According to the breaking capacity: L-standard breaking type; M-second high breaking type; H-high breaking type

Technical parameters

1, Instantaneous action characteristic setting value of the circuit breaker for distribution is 10In±20%, DAM2-1250 is 7In±20%; Instantaneous action characteristic set value of the circuit breaker for motor protection is 12In ± 20%.
2, The rated value of the circuit breaker in Table 2.
3, In the ambient temperature of +40ºC, the circuit breaker for distribution over-current release action characteristics shown in Table 3, the circuit breaker for motor protection over-current release action characteristics shown in Table 4.

Rated value of the circuit break

Introduction

DAM2E CM1 Electronic adjustable moulded case circuit breaker has three protection function, the circuit breaker with utilization category B connected with other short-circuit protection device in the same circuit has completely optional under short circuit circumstance; With five tripping features, the user can set the equipment through the shunt release according to the load current, electronic shunt release is powered by circuit breaker itself; current signal and control power is from the circle circuit transformer installed in the circuit breaker; With fire protection shunt release for alarming but not trip, when the load current is overloaded, the circuit breaker does not trip, and output the passive contact, driving the corresponding alarm device; The dimensions and specifications are the same as those of DAM2 CM1 series MCCB, the installation can be changed.

 

Application

1. The elevation of the installation site is not more than 2000m.
2. The ambient temperature is not more than +40ºC, and the average temperature within 24h is not more than +35ºC, the lower limit of the ambient temperature is -5ºC.
3. When the max temperature is +40ºC, the relative humidity of air is not more than 50%, can allow a higher relative humidity at a lower temperature, such as 90% at 20ºC, special measures should be taken for the condensation produced occasionally on the product due to temperature changes.
4. The pollution degree is 3.
5. The circuit breaker installation of main circuit category is class III, the installation category of auxiliary circuit and control circuit not connect to the main circuit is II.
6. Use category is A or B.

 

Important information

1) No code for circuit breaker for distribution, 2 for circuit breaker for protecting motor.
2) No code for handle direct operation, P for electric operation, Z for the rotating handle.
2. Classification
A. According to the rated limit short-circuit breaking capacity, divided into standard (S), high breaking (H);
B. According to the mode of connection, divided into three types: front connection, rear connection and plug-in;
C. According to the pole, divided into three-poles and four-poles. The N-phase of the 4-pole products is not equipped with the overcurrent release, and the N-phase is on-off with the other phase;
D. According to the accessory device, divided into with accessory device and without accessory device: accessory device is divided into internal and external devices: the internal device has shunt release, under voltage release, auxiliary contact, alarm contact, the external device has rotating handle operating mechanism, electric operation mechanism etc..

 

Accessory Name Accessory Code Tripping Mode
- 300 Electric Tripping Unit
Alarm Contact 308
Shunt Release 310
Auxiliary Contact 320
Undervoltage Release 330
Shunt Release + Auxiliary Contact 340
Shunt Release + Undervoltage Release 350
Two Groups of Auxiliary Contacts 360
Auxiliary Contact + Undervoltage Release 370
Alarm Contact + Shunt Release 318
Alarm Contact + Auxiliary Contact 328
Undervoltage Release + Alarm Contact 338
Auxiliary Contact + Alarm Contact + Shunt Release 348
Two Groups of Auxiliary Contacts + Alarm Contact 368
Undervoltage Release + Auxiliary Contact + Alarm Contact 378

Note: 1. DAM2E-100, 225 only have accessories of 308, 310, 320, 330, 328;
2. DAM2E-400 only have 3-pole accessories of 308, 310, 320, 330, 328;
3. DAM2E-400 only have no 4-pole accessories of 350, 318, 338, 348, 378.

in the setting, the dial switch must be set in place!

1. Adjust overload long delay action current Ir1, according to the different circuit breaker rated current, 4-10 files can be adjusted;
2. Adjust long delay action time t1, 4 files can be adjusted;
3. Adjust short-circuit short-delay action current Ir2, 9 files can be adjusted;
4. Adjust short delay action time t2, 4 files can be adjusted;
5. Adjust short-circuit instantaneous action current Ir3 action, 9 files can be adjusted;
6. Adjust pre-alarm action current Ir0, 7 files can be adjusted.

Technical parameters

The setting range of intelligent controller is shown in the table

Setting Project Setting Range
Setting value of overload long delay Current setting value lr1 (30~100)A,(100~250)A,(200~400)A,(400~630)A,(630~800)A,(800~1250)A
Time setting value t1 (12,60,80,100)s
Setting value of short circuit and short delay Current setting value lr2 (2~12)In
Time setting value t2 (0.06, 0.1, 0.2, 0.3)s
Setting value of instantaneous short circuit Current setting value lr3 (4~14)In

The main technical data of circuit breaker are shown in table

Model DAM2E-100 DAM2E-250 DAM2E-400 DAM2E-630 DAM2E-800 DAM2E-1250
Frame Current Inm(A) 100 250 400 630 800 1250
Breaking Capacity L M L M L M M H M H H
Rated Current In(A) 63,80,100 225,250 300,400 500,630 700,800 1000,1250
Pole 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4
Rated Operational Voltage Ue(V) AC400
Rated Insulation Voltage Ui(V) 800
Rated Impulse Withstand Voltage Uimp(V) 8000
Rated limit short circuit breaking capacity Icu(kA) 50 85 50 85 65 100 65 100 65 100 80
Rated running short circuit breaking capability Ics(kA) 35 50 35 50 42 65 42 62 42 62 50
Rated short-time withstand current Icw/0.5s(kA) - - 5 8 10 15/1S
Usage Category A A B B B B
Flashover Distance (mm) ≤50 ≤50 ≤100 ≤100 ≤100  
Operating Performance Power-on (Times) 1500 1000 1000 500 500 500
Power-off (Times) 8500 7000 4000 3000 3000 3000

Characteristics of release

a. Characteristics of Electric Trip Unit
With overload long-delay inverse time, short-circuit short-delay inverse time, short-circuit short delay time limit, short-circuit instantaneous action and other protection features, the protection characteristics can be set up by the users.
b. Overload long delay inverse time protection action characteristics in Table 4.
c. Short-circuit short-delay protection action characteristics in Table 5.
d. Short-circuit instantaneous protection action characteristics in Table 6.

Controller Types Basic type Intelligent communication type, programming communication type, liquid crystal type
Current Action Time
1.05lr1 No action within 2 hours
1.3lr1 ≤1h action
2lr1 Inm=100A, 250A Setting time t1(s) t1=(12, 60, 80, 100)s 12s-100s(most progress 1s)
Inm=400A, 630A, 800A Setting time t1(s) t1=(12, 60, 80, 100)s 12s-100s(most progress 1s)
Thermal Memory 30min, can be cleared after power off (this function is optional function in intelligent communication type and programming communication type)

1. Action time I²t1 = (2Ir1) ²t1 (1.2Ir1≤I <ir2);
2. Action time tolerance is ± 20%;
3. Returnable time is not less than 70% action time.

Short delay overcurrent protection characteristics

Current Action Time
Ir2≤I<1.5Ir2 Inverse Time I²t2=(1.5Ir2)²t2
1.5Ir2≤I Definite time Setting time t2(s) 0.06 0.1 0.2 0.3
Tolerance (s) ±0.02 ±0.03 ±0.04 ±0.06
Returnable time (s)       0.21

Note: Inverse time action time tolerance is ± 20%.

Short-circuit instantaneous protection action characteristics

Rated Current 100, 225(250) 400, 630 800
Setting Current Ir3=4, 6, 7, 8, 10,
11, 12, 13, 14
Ir3=4, 6, 7, 8, 10,
11, 12, 13, 14
Ir3=4, 5, 6, 7, 8,
9, 10, 11, 12
Operation Characteristics I≤0.85Ir3 non-operation
I≥1.15Ir3 operatino

Technical data of accessory device

a. Rated values of auxiliary contacts and alarm contacts are shown in table

 

Type Frame Rated Current
Inm(A)
Conventional Thermal Current
Ith(A)
Rated Operational Current Ie(A)
AC400V DC220V
Auxiliary Contact Inm≤400 3 0.3 0.15
Inm≥400 3 0.4 0.15
Alarm Contact 100≤Inm≤800 3 0.3 0.15

b. The rated control power supply voltage (Us) and rated operating voltage (Ue) of the control circuit release and electric mechanism are shown in Table 8

Type Rated Voltage (V)
AC50Hz DC
Release Shunt Release Us 220/380 110,220
Undervoltage Release Ue 220/380 -
Electric Mechanism Us 220/380 110,220

c. When the applied voltage of the shunt release is between 70%~100% of the rated power voltage, the circuit breaker should be reliably broken.
d. When the power voltage drops to 70% ~ 35% of the rated voltage of the undervoltage release, the undervoltage release can reliably break the circuit breaker; When the power voltage is lower than 35% rated voltage of the undervoltage release, the undervoltage release can prevent the circuit breaker from closing; When the power voltage is higher than 85% rated voltage of the undervoltage release, the undervoltage release can ensure the reliable closing of the circuit breaker.
e. Electric operating mechanism at the rated frequency, between 85% ~ 110% power voltage, the circuit breaker can be reliably closed.

Outline and Installation Dimensions

 

1. The dimensions are shown in figure 3~figure 6 and the table

(1) Dimensions of front connection see Figure 3 (X-X, Y-Y is the center of 3P circuit breaker)

Model DAM2E-100 DAM2E-250 DAM2E-400 DAM2E-630 DAM2E-800
Front Connection W 92 107 150   210
W1 60 70 96   140
L 150 165 257   280
L1 100 132 220   240
L2 132 144 244   243
H 93 90 107   116
H1 112 110 147   155
H2 29 24 38   46
H3 12 5 9.5   15
H4 4 4 6.5   5
E 55 65 92   83
F 25 25 68   68
G 18 22 30   44
W2 122 142 198   280
W3 90 105 144   210
M1 M8 M8 M10 M10 M12

(2) Dimensions of rear connection see Figure 4 and 5
(3) Dimensions of plug-in type front connection see Figure 6
(4) Dimensions of plug-in type rear connection see Figure 7

Model DAM2E-100 DAM2E-250 DAM2E-400 DAM2E-630 DAM2E-800
Rear Connection L4 164 173 267   295
H5 53 55 68   84
H6 93 100 128   -
H7 35 35 37   37
M1 M8 M8 M10 M10 M12
d - 8.5 10.5   13
t - - 8.5   16
Plug-in Connection L6 168 183 279   296
H8 50 50 60   61
H9 64 72 84   97
H10 76 87 107   148
H11 18 18 21   16
M1 M8 M8 M10 M10 M12
M2 M6 M6 M6 M8 M8
L7 220 252 357   -
L8 250 276 387   -

2. Dimensions for mounting plate opening

(1) Dimensions of front connection see Figure 8 (X-X, Y-Y is the center of 3P circuit breaker)

Model DAM2E-100 DAM2E-250 DAM2E-400 DAM2E-630 DAM2E-800
Pole 3 4 3 4 3 4 3 4 3
Dimensions for mounting plate opening (mm) A 30 35 44 70 70
B 129 126 194 243 303
d 4.5 4.5 7 7 7

(2) Dimensions of rear connection see Figure 9 (X-X, Y-Y is the center of 3P circuit breaker)

Model DAM2E-100 DAM2E-250 DAM2E-400 DAM2E-630 DAM2E-800
Pole 3 4 3 4 3 4 3 4 3 4
Dimensions for mounting plate opening (mm) A 60 - 70 - 96 -     140 -
A1 - 90 - 105 - 144     - 210
B 72 - 87 - 124 -     178 -
B1 - 102 - 122 - 172     - 248
C 90 93 164   158
D 132 144 224   243
Φ1 22 24 32   48
Φ2 5.5 5.5 6.5   7

 

Model DAM2E-100 DAM2E-250 DAM2E-400
Pole 3 3 3
Dimensions for mounting plate opening (mm) A 92 107 150
B 60 70 60
C 56 54 129
D 38 63.2 62
E 92 94 109
d 6.5 6.5 8.5

(4) Dimensions of plug-in type rear connection see Figure 10 (X-X, Y-Y is the center of 3P circuit breaker)

Model DAM2E-100 DAM2E-250 DAM2E-400 DAM2E-630 DAM2E-800
Pole 3 4 3 4 3 4 3 4 3 4
Dimensions for mounting plate opening (mm) A 94 - 110 - 152 -     215 -
A1 - 125 - 145 - 200     - 283
B 60 - 70 - 60 -     140 -
B1 - 90 - 105 - 108     - 210
C 56 54 129   143
D 48 58 65   65
E 90 88 166   183
d 6.5 6.5 8.5   10
           
     
                 
       
               
       
       
         
       
             
       
       
         
       
               
       
       
         
       
             
       
       
         
       
             
       
         
             
         

Note: 2-poles, 4-poles circuit breakers, divided into L, M, H, they have the same breaking index as M-type.

Characteristics of inverse time breaking action of circuit breakers over-current release for power distribution when every pole is power-on at the same time

No. Test current I/In Set time Initial state
1 Conventional non-tripping current 1.05 2h(In>63A),1h(In≤63A) Cold
2 Conventional non-tripping current 1.30 2h(In>63A),1h(In≤63A) Immediately after Test 1

Instantaneous action characteristic setting value of the circuit breaker for distribution is 10In±20%, and instantaneous action characteristic setting value of the circuit breaker for motor protection is 12In±20%.

Characteristics of inverse time breaking action of circuit breakers over-current release for motor protection when every pole is power-on at the same time

No. I/In Set time Initial state Remark
1 1.0 >2h Cold  
2 1.2 ≤2h Immediately after Test 1  
3 1.5 ≤4min Cold 10≤n≤225
≤8min 225 < in ≤ 630
4 7.2 4s≤T≤10s Cold 10≤In≤225
6s≤T≤20s 225 < in ≤ 630

Accessories

1,Internal accessory of circuit breakers

1.1 Shunt release
Rated control supply voltage of the shunt release: AC50Hz, 230V, 400; DC110V, 220V, 24V; When between 70%~110%, can break the circuit breaker reliably.<

When rated control supply voltage of the shunt release is DC24V, the maximum length of copper wire should meet the following requirements

Rated control
supply voltage Uc(DC24V)/Conductor area
1.5mm² 2.5mm²
100%Uc
85%Uc
150m
100m
250m
160m

If the requirements of the above table are not met, it is recommended to design the shunt release control circuit using the following figure

1.2 Under-voltage release

When the power supply voltage drops to under-voltage release rated voltage of 70% to 35% of the range, the under-voltage
release circuit breaker reliable break; when the supply voltage is below the rated voltage undervoltage release 35% , Under-voltage
release to prevent the circuit breaker is closed; when the supply voltage is higher than 85% of the rated voltage of the under-voltage
release, the under-voltage release ensures that the circuit breaker is closed. The undervoltage releases are rated at AC50Hz, 230V,
400V.
Special Note: The circuit breaker with undervoltage release, only in the under-voltage with rated voltage, which can open and close
normally.

1.3 Pre-paid meter dedicated release

The rated operating voltage Ue of the pre-paid meter dedicated release is AC230/50Hz, it can worknormally in the range of (65% ~ 110%) Ue. When the Ctrl is cut off, the circuit breaker will delay 0.5s ~ 2s to be opening.

Wiring diagram of pre-paid meter dedicated release 

1.4 The rated value of auxiliary contacts and alarm contacts in Table 5

Classification Conventional thermal current (Ith) Rated current when

 

AC 400V Ie(AC-15)

Rated current when

 

DC 220V Ie(DC-13)

Auxiliary contact 3 0.4 0.15
Alarm contact 3 0.3 0.15

a. Auxiliary contact

b. Alarm contact
Alarm contacts don't act when the circuit breaker opens and closes normally, alarm contacts switch between normal opening and normal closing only after free tripping or fault tripping.

 

2,External Accessory for Circuit Breakers

2.1 Motor operating mechanism. The rated value and code are shown in Table 6.

Category/Model DAM2-63. 125. 250 DAM2-400. 630. 800. 1250
Structure type Electromagnet Motor
AC voltage code AC50Hz,230V,400 AC50Hz,230V,400
DC voltage code DC110V,220V DC110V,220V

NOTE: After the tripping of circuit-breaker with electric operating mechanism, the electric operating mechanism must make the circuit-breaker buckle again, then it can close.

The principle diagram of the opening and closing of DAM2-63,100,225 electric operating mechanism(AC)

The principle diagram of the opening and closing of DAM2-400,630,800,1250 electric operating mechanism(AC)

2.2 Installation dimensions of manual operating mechanism shown in Table 10
Diagram of handle mounting hole of DAM2-63~800

Total height of electric/manual operating mechanism of circuit breaker (mm)(shown in Table 12)

Model Total height of electric
operating mechanism H
Installation dimensions

 

of manual operating mechanism H

DAM2L-63 155 49
DAM2M/H-63 164 49
DAM2L-100 152 51
DAM2M/H-100 170 51
DAM2L-225 182 54
DAM2M/H-225 199 54
DAM2L/M/H-400 255 88
DAM2M/H-630 262 89
DAM2M/H-800 261 96
DAM2H-1250 290 103

How to fast Selection Table of DAM2 Series Molded Case Circuit Breaker

Corresponding
letters
Function name Function corresponding to the model
a Model features DAM2 Molded Case

 

Circuit Breaker

b Frame rated current code 63A,100A,225A,

 

400A,630A,800A,

1250A

c Breaking capacity characteristic
code
L-standard breaking type;

 

M-second high breaking type;

H-high breaking type

d Operation mode code No code for handle operation;

 

P for electric operation;

Z for turning handle operation

e Pole 2-two poles;

 

3-three poles;

4-four poles

f Release name 2 Electromagnetic release;

 

3 Double release

g Accessory 00 Without accessory
08 Alarm contact
10 Shunt release
20 Auxiliary contact
30 Undervoltage release
40 Shunt release, Auxiliary contact
50 Shunt release, Undervoltage release
60 Two sets of auxiliary contacts
70 Auxiliary contact, Undervoltage release
18 Shunt release, Alarm contact
28 Auxiliary contact, Alarm contact
38 Undervoltage release, Alarm contact
48 Shunt release, Auxiliary contact, Alarm contact
58 Shunt release, Undervoltage release, Alarm contact
68 Two sets of auxiliary contacts, Alarm contact
78 Auxiliary contact, Undervoltage release, Alarm contact
10Y Pre-paid meter dedicated release
40Y Pre-paid meter dedicated release, Auxiliary contact
50Y Pre-paid meter dedicated release, Auxiliary contact, Undervoltage release
18Y Pre-paid meter dedicated release, Alarm contact
48Y Pre-paid meter dedicated release, Auxiliary contact, Alarm contact
58Y Pre-paid meter dedicated release, Undervoltage release, Alarm contact
h Application No code for distribution;

 

2 for motor protection

i Conventional products No code;

 

T for transparent cover products

j Amperage 10,16,20,25,32,63,80,100,125,160,180,200
,225,250,315,350,400,500,630,700,800,1000
,1250

Example: DAM2L-100 / 33102 63A means DAM2-type molded case circuit breaker, frame rated current is 100A, breaking capacity is the standard type, handle operation, 3 poles, double release, with shuntrelease, for motor protection, rated current is 63A.
Selection, installation, use should be consistent with the product manual or the relevant national standards.
Note: N-pole type of 4P circuit breaker is divided into A-type, B-type, which is not specified defaults to B type.



Working principle
The main contact of the molded case circuit breaker is manual manipulation or electric closing. After the main contact is closed, the free release mechanism locks the main contact into the closing position. The over current trip coil and the thermal trip element are connected in series with the main circuit. The under voltage release coil and the power supply are connected in parallel.

Dam2e-400m Electronic MCCB
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now