Durable MCCB Circuit Breaker 250A with Unflaming BMC Material

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 26/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
  • Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
  • Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
  • Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
  • Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
Find Similar Products

Basic Info.

Model NO.
DAM1-250
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
ISO9001-2000, CE, CB, CCC, Asta, Semko, RoHS
Base
BMC Unflaming Material
Rated Insulation Voltage
1000V
Rated Operation Voltage
400/415V
Outline Dimension
170X105X103.5mm
Transport Package
Carton
Specification
63, 80, 100, 125, 160, 200, 250, 315A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
8536200000
Production Capacity
20000PCS/Month

Product Description


Introduction

The exceptional DAM1 series circuit breakers are meticulously engineered to conduct current seamlessly under normal operations and to efficiently interrupt the flow during short circuits, overloads, and unacceptable voltage variations. These circuit breakers are expertly crafted for use in electrical systems with an operational voltage cap of 400V, accommodating a broad range of rated currents from 12.5 to 1600A, ensuring protection and reliability across a variety of applications.

These circuit breakers are designed in strict adherence to the rigorous standards of EN 60947-1 and EN 60947-2, ensuring superior performance and safety.


Thermal-Magnetic Circuit Breakers:

Thermal Protection Function: (Essential for protection under overload conditions)
The innovative bimetal thermal protection system features a sophisticated combination of two metals, each with distinct thermal expansion coefficients. Upon heating, the bimetallic strip elegantly bends toward the metal with the lesser expansion rate, triggering a delicate notch that initiates the precise opening of the breaker mechanism. The rate at which this bending progresses is intricately linked to the magnitude of the current traversing the breaker, as increased current corresponds to heightened thermal activity. This ingenious design ensures the overcurrent protection functionality of the breaker is effectively achieved when load currents exceed the predetermined rated threshold.
Magnetic Protection Function: (For protection under short circuit conditions) Another vital function of the breaker is to safeguard the connected circuit against short circuits. These may occur when phases come into contact with each other or when a phase contacts the ground. In such instances, an extraordinarily high current flows through the cables, necessitating an immediate interruption by the breaker to protect the connected load. The breaker executes this critical task through a robust mechanical opening mechanism that operates with swift efficiency, utilizing the magnetic force generated by the magnetic field induced by the short circuit current.
Thermal-Magnetic fixed type Circuit Breakers  
Model DAM1-250
Breaking Capacity Code N S H G
Rated Current of Frame size- Inm                                                                    (A) 250A
Rated Current-In(40,50 or 55ºC)                                                                      (A) 63 - 80-100-125 - 160(180) -  200(225) - 250(320)A
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz                                                    (V) 750V
Rated operation Voltage  -Ue(a.c.) 50-60Hz                                                    (V) 400/415V
Number of Pole 3P /4P
Rated ultimate short Circuit breaking Capacity  kA  Icu AC400V/50Hz O-CO          (KA) 35 50 65 85
Rated service short Circuit breaking Capacity  kA  Ics AC400V/50Hz O-CO-CO     (KA) 26.25 37.5 48.75 51
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO         (KA) 77/0.25 114/0.25 143/0.2 178/0.2
Rated impulse withstand Voltage -Uimp                                                                            (V) 8000
Dielectric Propery (V) 3000
lonization distance                                                                                                              (mm) 30/0
Endurance Total Cycles 8000
Electrical Life 1000
Mechanical Life 7000
Over Current trip Thermal and Magnetic release fix type
Category (EN 60947-2/IEC 60947-2) Main circuit A/B
Auxiliary circuit AC-15
Under Voltage Release 
Shunt Release
Auxiliary Contact
Alarm Contact
Auxiliary Contact and Alarm Contact
Handle Operation Mechanism
Electrical Operastion Mechanism 
DIN clips -
Terminal cover    
Phase seperator    
Extention Handle     -
  W (mm) 3P 105
4P 140
L (mm) 3P 170
4P 170
H (mm) 3P 103.5
4P 103.5
Weight Fixed version 3P/4P 2.7/3.5 41.5/5.5
Plug-in version 3P/4P 3.2/4.2 4.6/6
Draw out version 3P/4P 3.6/4.6 5/6.4


Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
Durable MCCB Circuit Breaker 250A with Unflaming BMC Material

Durable MCCB Circuit Breaker 250A with Unflaming BMC Material
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier