Afddle 63A 1p+N Residual Current Circuit Breaker 50Hz
|
Still deciding? Get samples of $ !
Request Sample
|
Product Details
| Customization: | Available |
|---|---|
| Breaking Capacity: | Low Voltage Circuit Breakers |
| Operation: | Manual Type |
Manufacturer/Factory & Trading Company
360° Virtual Tour
Diamond Member Since 2020
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
Cooperated with Fortune 500
Years of Export Experience
Exhibition Experience
The supplier has import and export rights
This supplier has Cooperated with Fortune 500 companies
The export experience of the supplier is more than 10 years
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Sign In to see all verified strength labels (25)
Find Similar Products
Basic Info.
- Speed
- High-Speed Circuit Breaker
- Arc-extinguishing Medium
- Arc Chamber
- Installation
- Fixed
- Structure
- MCB
- Poles Number
- 3p+N
- Type
- Circuit Breaker
- Function
- Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
- Certification
- ISO9001-2000, CE, CB, CCC
- Release Type
- Electromagnetic Type
- Rated Residual Current Motion
- 10mA,30mA,100mA,300mA
- Residual Leakage Current Curve
- a,AC,S Type
- Transport Package
- Carton
- Specification
- 6, 10, 16, 20, 25, 32, 40, 50, 63A
- Trademark
- CDADA, OEM, ODM
- Origin
- Shanghai
- HS Code
- 85362000
- Production Capacity
- 200000PCS/Month
Product Description

I) Product introduction
The arc fault dectection device (hereinafter referred to as AFDD/AFDDLE) can effectively detect the fault arc in the access line, including the fault parallel arc and the fault series arc. When the fault arc causing fire is detected in the line, it can perform the function of disconnection and power-off to realize the purpose of early warning of fire. The arc fault dectection device is applicable to the electrical lines of 10kW and below in industrial and civil buildings. The length of the protection line should not be greater than 100m. The products comply with GB/t31143-2014 IEC62602 standard and can be applied to nursing homes, schools, commercial buildings, hotels, factories, warehouses, libraries, offices, family houses, and entertainment places.
II)Technical Data Sheet
| Items | Value |
| Model | AFDD without leakage protection/AFDDLE with leakage protection |
| Working power supply | Rated voltage: AC230V |
| Rated frequency | 50Hz |
| Monitoring alarm | Fault arc alarm (load below AC63A) |
| Voltage | Rated value AC230V |
| electric current | Rated value: AC63A and below |
| Overall dimensions | 82*35.2*62mm |
| Installation method | 35mm guide rail installation |
| Run indicator | Normal operation, the indicator flashes |
| SET | Set button |
| Breaking capacity | Rated short-circuit breaking capacity ICN (KA): 6 |
| Protection level | IP20 |
| Wiring capacity | 1~25mm |
| Outlet characteristics | C,D |
| Electrostatic discharge resistance | Air discharge > 8; Contact discharge > 6 |
| Pulse group anti-interference | 6KA |
| Surge impact interference | 4KA |
| Operating ambient temperature | -23~+55ºC |
| Damp heat resistance | Type 2 |
| class of pollution | 2 |
| Installation type | Level M |
| altitude | 2000m |
| Installation environment | Ground without significant vibration and impact |
| Mechanical life | 20000cycles |
| Electrical life | 10000cycles |
III) Product Settings
T key: Test key - Multi-functional press keyGreen light status: Running status
Press the "T key" and release it quickly (note that it is triggered by release) to test the the breaking function of AFDD protection.
Red light flashing status: Fault arc alarm status.
The alarm will be immediately lifted after pressing the "T key"
Set the AFD detection mode:
When the green light is on, hold down the "T key "for about 3 seconds and the green light will go off. This indicates that you have entered the Settings status. Press the "T key" again, and the green light will flash to indicate the current working mode. It switches once each time it is pressed!
There are four working modes in total:
- Flash once: Anti-interference mode
- Flash twice: Slow mode
- Flash three times: Standard mode
- Flash four times: Enhanced mode (not a dedicated scene, not recommended for use)
It takes effect immediately after switching. Wait for 10 seconds and it will automatically exit the setting state. You can also long press the "T key" to exit.

IV) Wiring diagram
With leakage AFDDLE Without leakage AFDD
V) Product outline dimension and structure definition
Send your message to this supplier
People who viewed this also viewed
Product Groups
More
Find Similar Products By Category
- Supplier Homepage
- Products
- RCBO
- Afddle 63A 1p+N Residual Current Circuit Breaker 50Hz
Related Categories
Hot Searches
More