Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 14/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use
  • Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use
  • Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use
  • Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use
  • Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use
  • Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use
Find Similar Products

Basic Info.

Model NO.
DAM11
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
ISO9001-2000, CE, CB, CCC, Kema, Asta, Semko, RoHS
Cover
BMC Unflaming Material
Base
BMC Unflaming Material
Terminal
with Terminal Box
Neutral Pole
Left Side
Rated Insulation Voltage
1000V
Rated Operation Voltage
400/415V
Transport Package
Carton
Specification
16A-1250A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
8536200000
Production Capacity
40000PCS/Month

Product Description

Product Model: DAM11 Series: Moulded-case Circuit Breaker
Product overview

The DAM11 series, including DAM11, DAM11LY, DAM11RT, DAM11E, and DAM11EL, represents our latest innovation in circuit breaker technology. These upgraded models are crafted by integrating the superior features of leading international products with the specific needs of both domestic and global markets.
Designed with an insulation voltage of up to 1000V, these circuit breakers are perfect for AC50Hz distribution systems with a rated working voltage of 690V and a current range from 10A to 800A. They are essential for distributing electrical power, protecting circuits and equipment from overload, short circuits, and under-voltage, and can also handle the infrequent startup of motors, safeguarding them against similar issues.
Offering a compact size, high breaking capacity, and minimal flashover, our circuit breakers are the ideal choice for users. Their versatile design allows for both vertical and horizontal installation.
The DAM11DC series DC moulded-case circuit breakers are engineered for DC systems with voltages up to 1000V and currents ranging from 10A to 800A. These breakers are vital for distributing electrical power and protecting circuits and equipment from overload and short circuits.
Our products feature flexible wiring options, allowing for power feeds from both the top and bottom, and they are designed to be polarity-free for ease of installation.
Compliance: Meets standards IEC60947-2 and GB14048.2, ensuring top-tier quality and reliability.
Ambient and installation conditions

Operational Altitude: Reliable up to 2000m.
Ambient Temperature: Operational between -5ºC to +40ºC, and up to +45ºC for marine environments.
Humidity Resistance: Designed to withstand damp air conditions.
Mould Resistance: Built to resist mould effects.
Radiation Resistance: Capable of withstanding nuclear radiation.
Maximum Inclination: Operational up to a 22.5º inclination.
Vibration Resistance: Reliable performance even under normal ship vibrations.
Seismic Performance: Remains reliable during earthquakes (4g).
Safe Environments: Suitable for locations free from explosive hazards and away from corrosive gases or conductive dust that could damage metal or insulation.
Weather Resistance: Must be kept away from rain and snow to ensure optimal performance.
DAM11 thermal overload technical data sheet Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use
Frame current (A) 125 160 250 400 630 800
Model DAM11-125C DAM11-125S DAM11-125H DAM11-160C DAM11-160S DAM11-160H DAM11-250C DAM11-250S DAM11-250H DAM11-400S DAM11-400H DAM11-630S DAM11-630H DAM11-800S DAM11-800H
Pole number 1, 2, 3, 4 2, 3, 4 3, 4 3, 4 3, 4 3, 4
Rated current (A) 10, 16, 20, 32, 25, 40, 50,63, 80, 100, 125 63, 80, 100, 125, 140, 160
100, 125, 140, 160, 180,200, 225, 250
250,315,350,400 250, 315, 350, 400, 500, 630 500, 630, 700, 800,1000,1250
Rated voltage (V) AC400V AC400V AC400V AC400V AC400V AC400V
Rated insulation voltage (V) AC1000V AC1000V AC1000V AC1000V AC1000V AC1000V
Short-circuit breaking capacity(KA)Icu/Ics AC400V 10/15 18/15 25/18 20/15 25/18 35/25 25/15 25/18 35/25 35/25 50/35 35/25 50/35 50/35 65/65
Operating cycle number Electrical life 6000 3000 3000 2000 2000 1500
Mechanical life 9000 7000 7000 4000 4000 4000
Outline dim(mm) 1P 25-130-68-90 - - -        
a-b-c-ca 2P 50-130-68-90 60-155-68-90 60-155-88-115        
  3P 75-130-68-90 90-155-68-90 90-155-88-115 105-165-68-92 105-165-88-115 140-257-103-155 140-257-103-155 210-275-103-155
4P 100-130-68-90 120-155-68-90 120-155-88-115 140-165-68-92 140-165-88-115 184-257-103-155 184-257-103-155 280-275-103-155
Weight (kg) 1P 0.32 - - -          
2P 0.5 0.55 1 1.1 1.5 1.7 5.5 5.7 9.5
3P 0.55 0.65 1.1 1.2 1.9 2.1 7 7.5 12.5
4P 0.65 0.8 1.4 1.5        
Electric operating device (MD)      
External driving operating handle      
Automatic release Thermal electromagnetic type Thermal electromagnetic type Thermal electromagnetic type
DAM11RT thermal adjustable and magnetic adjustable (TAMA) technical data sheet Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use
Frame current (A) 160 250 400 630 1250
Model DAM11RT-160S DAM11RT-160H DAM11RT-250S DAM11RT-250H DAM11RT-400S DAM11RT-400H DAM11RT-630S DAM11RT-630H DAM11RT-1250S DAM11RT-1250H
Pole number 3, 4 3, 4 3, 4 3, 4 3, 4
Rated current (A) 20-25, 25-32, 32-40, 40-50, 50-63, 100-125, 125-160, 160-200, 200-250A 200-250, 250-320,320-400 400-500, 500-630 630-800,800-1250
63-80,80-100, 100-125A, 125-160A AC400V AC400V AC400V
Rated voltage (V) AC400V AC400V AC1000V AC1000V AC1000V
Rated insulation voltage (V) AC1000V AC1000V 35/25 50/35 35/25 50/35 50/35 65/50
Short-circuit breaking capacity(KA)Icu/Ics AC400V 25/18 35/25 25/18 35/25 2000 2000 1500
Operating cycle number Electrical life 3000 3000 4000 4000 4000
Mechanical life 7000 7000 1000 1000 1000
Outline dim(mm) a-b-c-ca        
3P 90-155-68-90 90-155-88-115 105-165-68-92 105-165-88-115 140-257-103-155 140-257-103-155 210-275-103-155
4P 120-155-68-90 120-155-88-115 140-165-68-92 140-165-88-115 185-257-103-155 185-257-103-155 280-275-103-155
       
Weight (kg) 3P 1 1.1 1.5 1.7 5.5 5.7 9.5
4P 1.1 1.7 1.9 2.1 7 7.5 12.5
Electric operating device (MD)    
External driving    
operating handle
Automatic release Thermal electromagnetic type Thermal electromagnetic type
Mitsubishi Electronic MCCB: 2p, 3p, 4p Circuit Breaker for Industrial Use
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier