Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 4/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada
  • Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada
  • Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada
  • Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada
Find Similar Products

Basic Info.

Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCB
Poles Number
1p+N
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CB, CCC
Release Type
Electronic Type
Rated Residual Current Motion
10mA,30mA,100mA,300mA
Residual Leakage Current Curve
a,AC,S Type
Transport Package
Carton
Specification
6, 10, 16, 20, 25, 32, 40, 50, 63A
Trademark
CDADA, OEM, ODM
Origin
Shanghai
HS Code
85362000
Production Capacity
200000PCS/Month

Product Description

DABL-63 6kA 10kA Electronic Residual Current Device RCBO Circuit Breaker

Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada

Introduction
Introducing the DABL-63, a remarkable electronic residual current circuit breaker offered in robust 6kA and 10kA models. Carefully crafted by the renowned Shanghai DaDa Electric Co., Ltd., this device guarantees supreme stability and precise protection. With its rapid response and exceptional breaking capacity, it is housed in an elegant and compact design. Adhering to the stringent GB 10963 and IEC60898 standards, it epitomizes reliability and expert craftsmanship.

These unmatched circuit breakers are essential for protecting contactors, relays, and a vast range of electrical equipment from the dangers of overloads, ensuring your operations proceed smoothly and securely.

Key functions include superior short circuit protection, dependable overload protection, and effective isolation, providing a holistic safety solution.

Model
DABL-63 1P+N/2P RCBO Circuit Breaker
Rated current Rated frequency Rated operating voltage Rated residual current Rated insulation voltage Impulse withstand voltage Instantaneous trip type Rated breaking capacity W*H*L
6-63A 50-60Hz 230/400V 10,30,100,300A 500V 6KV B/C/D DABL-63 10KA, DABL-63 6KA 36/54mm*80.4mm*72mm

Technical parameters of the DABL-40 electronic residual current circuit breaker
Protection grade: IP20, delivering reliable defense against solid objects with limited protection against liquids.
Flame retardant grade: Grade 2, ensuring strong resistance against potential fire threats.
Mechanical endurance: 12,000 operations, showcasing outstanding durability and reliability for prolonged use.
Electrical endurance: 6,000 operations, guaranteeing consistent performance under electrical stresses.
Electric wire capacity: Capable of accommodating wires from 1mm to 25mm, meeting diverse installation demands.2
Operating temperature range: Engineered for optimal performance from -5°C to +40°C, adaptable to various environmental conditions.
Altitude: Suitable for applications up to 2000 meters, ensuring steadfast functionality in elevated locations.
Relative humidity: Performs effectively at 90% humidity at +20ºC; reduces to 50% at +40ºC, ensuring reliability in varied climates.
Pollution class: 2, denoting moderate environmental exposure.
Installation environment: For optimal function, avoid areas with significant shock and vibration.
Installation grade: Grade II, Grade III, providing flexibility to meet diverse installation standards.

Installable accessories for DABL-63 electronic residual current circuit breaker
Optional accessories such as auxiliary contact, alarm contact, shunt trip, undervoltage trip, and overvoltage trip enhance functionality and guarantee safety.

Advantages

· Seamlessly combines a differential protection electronic module with a DAB7-63 series circuit breaker, delivering an efficient protection solution.
· Offers premium protection against electric shock risks from direct contact with energized parts, prioritizing user safety.
· Features a clear contact position indicator for immediate status monitoring, enhancing operational transparency.
· Efficient functionality across a diverse temperature range from -25°C to +40°C, suitable for various environmental conditions.
· Ingenious terminal clamp notches minimize thermal losses and bolster mechanical connection stability, ensuring long-term reliability.
· Equipped with a convenient 'TEST' button to verify functionality and check connection accuracy, ensuring peak efficiency.
· Compact design comparable to a 2-modular item is realized through innovative element placement, optimizing space utilization.
· Enhanced 6kA capability enables AVDTs to serve as primary protection switches, broadening their application scope.
Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada
 
Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada
 
Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada
 
Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada
 
Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada
 
Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada
 
Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada
 
Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada
 
Enhanced RCBO Approval: 100mA AC Type Dabl-63 Electronic Breaker Cdada
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier