250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 26/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • 250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification
  • 250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification
  • 250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification
  • 250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification
  • 250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification
  • 250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification
Find Similar Products

Basic Info.

Model NO.
DAM1-250
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
ISO9001-2000, CE, CB, CCC, Asta, Semko, RoHS
Base
BMC Unflaming Material
Rated Insulation Voltage
1000V
Rated Operation Voltage
400/415V
Outline Dimension
170X105X103.5mm
Transport Package
Carton
Specification
63, 80, 100, 125, 160, 200, 250, 315A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
8536200000
Production Capacity
20000PCS/Month

Product Description

Introduction

The DAM1 series of circuit breakers are masterfully engineered to handle current conduction under normal conditions and to effectively interrupt it during short circuits, overloads, and other inadmissible voltage deviations. Additionally, these breakers facilitate operational engagement and disengagement of electric circuits. Tailored for electric systems with operational voltages up to 400V and supporting rated currents from 12.5A to 1600A, these breakers are designed to ensure optimal performance and safety.

These circuit breakers are fully compliant with the rigorous standards of EN 60947-1 and EN 60947-2.

Thermal-Magnetic Circuit Breakers:

Thermal Protection Function: (Provides protection under overload conditions)
The thermal protection mechanism relies on a bimetallic component, comprising two metals with distinct thermal expansion coefficients. When heated, the bimetal bends toward the metal with lesser expansion, triggering a mechanism that opens the breaker. The bimetal's bending rate is directly proportional to the current's magnitude, as increased current generates more heat. Thus, the breaker effectively provides overload protection when the load current exceeds the rated level.
Magnetic Protection Function:(Ensures protection under short circuit conditions) Another critical role of the breaker is tosafeguard the connected circuit against shortcircuits. Such shorts may result fromphase-to-phase or phase-to-ground contact.In the event of a short circuit, an immensecurrent surge travels through the cables, necessitatingrapid system disconnection to prevent thermaldamage. The breaker mustinstantly disconnect to protect theconnected load. This action is executed by amechanical release mechanism,which is activatedby magnetization induced by themagnetic field generated by the short circuit current.
Thermal-Magnetic fixed type Circuit Breakers  
Model DAM1-250
Breaking Capacity Code N S H G
Rated Current of Frame size- Inm                                                                    (A) 250A
Rated Current-In(40,50 or 55ºC)                                                                      (A) 63 - 80-100-125 - 160(180) -  200(225) - 250(320)A
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz                                                    (V) 750V
Rated operation Voltage  -Ue(a.c.) 50-60Hz                                                    (V) 400/415V
Number of Pole 3P /4P
Rated ultimate short Circuit breaking Capacity  kA  Icu AC400V/50Hz O-CO          (KA) 35 50 65 85
Rated service short Circuit breaking Capacity  kA  Ics AC400V/50Hz O-CO-CO     (KA) 26.25 37.5 48.75 51
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO         (KA) 77/0.25 114/0.25 143/0.2 178/0.2
Rated impulse withstand Voltage -Uimp                                                                            (V) 8000
Dielectric Propery (V) 3000
lonization distance                                                                                                              (mm) 30/0
Endurance Total Cycles 8000
Electrical Life 1000
Mechanical Life 7000
Over Current trip Thermal and Magnetic release fix type
Category (EN 60947-2/IEC 60947-2) Main circuit A/B
Auxiliary circuit AC-15
Under Voltage Release 
Shunt Release
Auxiliary Contact
Alarm Contact
Auxiliary Contact and Alarm Contact
Handle Operation Mechanism
Electrical Operastion Mechanism 
DIN clips -
Terminal cover    
Phase seperator    
Extention Handle     -
  W (mm) 3P 105
4P 140
L (mm) 3P 170
4P 170
H (mm) 3P 103.5
4P 103.5
Weight Fixed version 3P/4P 2.7/3.5 41.5/5.5
Plug-in version 3P/4P 3.2/4.2 4.6/6
Draw out version 3P/4P 3.6/4.6 5/6.4

250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification250A MCCB Circuit Breaker with BMC Base and Kema Asta Certification