Low Voltage Switchgear Circuit Breaker 250A with High Performance

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 10/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Low Voltage Switchgear Circuit Breaker 250A with High Performance
  • Low Voltage Switchgear Circuit Breaker 250A with High Performance
  • Low Voltage Switchgear Circuit Breaker 250A with High Performance
  • Low Voltage Switchgear Circuit Breaker 250A with High Performance
  • Low Voltage Switchgear Circuit Breaker 250A with High Performance
  • Low Voltage Switchgear Circuit Breaker 250A with High Performance
Find Similar Products

Basic Info.

Model NO.
CM1-125
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Transport Package
Carton
Specification
12.5, 16, 20, 25, 32, 40, 50, 70, 80, 100A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
85362000
Production Capacity
10000PCS/Month

Product Description

Low Voltage Switchgear Circuit Breaker 250A with High Performance


Discover the DAM2 series Moulded Case Circuit Breaker, a masterpiece of advanced innovation and precision, crafted using state-of-the-art international technology. These cutting-edge breakers showcase a remarkably compact design, exceptional breaking capacity, and a minimized arc-over distance, coupled with robust shake-proof construction. These features make them the prime choice for numerous applications, whether on land or at sea.

Application

The DAM2 (CM1) series circuit breaker is an engineering marvel with a rated insulation voltage of 800V. Perfectly suited for AC distribution networks at 50Hz/60Hz, it manages a rated working voltage of up to 690V and a rated current of up to 1250A. Ideal for power distribution and circuit protection, it ensures the utmost safety of equipment against overloads, short-circuits, under-voltage, and more. It is adaptable for infrequent circuit conversions and motor starts, providing unmatched versatility. Installable in both vertical and horizontal positions, it offers flexible usability. Designated for isolation by the symbol " ", the DAM2 MCCB strictly follows IEC60947-2 standards for low-voltage switchgear and control equipment, solidifying its status as an exemplary circuit breaker.

Low Voltage Switchgear Circuit Breaker 250A with High PerformanceLow Voltage Switchgear Circuit Breaker 250A with High Performance

Normal operating conditions

1. Ambient air temperature: Keep between -5ºC to +40ºC, ensuring the daily average does not exceed +35ºC.
2. Altitude: Ensure the installation site altitude does not exceed 2000 meters for optimal performance.
3. Atmospheric conditions: At +40ºC, relative humidity should not surpass 50%, yet higher humidity is permissible at lower temperatures. The maximum average relative humidity is 90%, with a minimum average monthly temperature of +25ºC, acknowledging potential condensation due to temperature changes.
4. Pollution Degree: 3.

Selection of instructions

Classified by pole types:
Type A: N-pole without over-current release components, remains continuously connected, and does not operate in conjunction with the other three poles.
Type B: N-pole without over-current release components, operates simultaneously with the other three poles (N-pole activates before deactivation).
Type C: N-pole with over-current release components, functions in harmony with the other three poles (N-pole activates before deactivation).

Classified by rated current of over-current release:
DAM2-63 MCCB Available in an extensive selection of nine ratings: 6, 10, 16, 20, 25, 32, 40, 50, and 63 A.
DAM2-100 MCCB Available in nine versatile ratings: 16, 20, 25, 32, 40, 50, 63, 80, and 100 A.
DAM2-250 MCCB Available in a solid range of seven ratings: 100, 125, 140, 160, 180, 200, 225, and 250 A.
DAM2-400 MCCB Available in five distinct ratings: 225, 250, 315, 350, and 400 A.
DAM2-630 MCCB Available in three robust ratings: 400, 500, and 630 A.
DAM2-800 MCCB Available in three formidable ratings: 630, 700, and 800 A.
DAM2-1250 MCCB: Unleash the power of choice with three formidable ratings: 800, 1000, and 1250 A, crafted to meet your most demanding specifications.
Remark: Kindly note that our specialized 6A version is exclusively engineered in the electromagnetic (instantaneous) type. Due to its specific constraints, general use is not advisable.
Wiring Options: Unlock the versatility of installation with our adaptable selection: front-of-board, back-of-board, or insertion type wiring. Customize your setup to precisely match your requirements with ease.
Over-Current Release Patterns: Select from our expertly designed thermodynamic-electromagnetic (dual) type or electromagnetic (instantaneous) type. Each pattern is meticulously crafted to meet diverse requirements, ensuring peak performance.
Outfit Options: Personalize your solution by opting for circuit breakers with or without outfit. This adaptable feature ensures you can effortlessly align with specific application needs.
Outfit Details: Elevate your system with a broad spectrum of accessories. Inner options include shunt release, under-voltage release, auxiliary contact, and alarm contact. Our outer accessories boast advanced turning handle and power-driven operation mechanisms, ensuring seamless integration and functionality.
Breaking Capacity: Embrace a wide spectrum of breaking capacities with our L-standard, M-second high, and H-high breaking types. Each is precisely engineered to suit various applications with exceptional accuracy.

Low Voltage Switchgear Circuit Breaker 250A with High PerformanceLow Voltage Switchgear Circuit Breaker 250A with High Performance


Technical Parameters

1. Instantaneous Action Characteristics: For distribution circuit breakers, experience a setting value of 10In±20%. The DAM2-1250 model is set at 7In±20%. Motor protection circuit breakers boast a setting value of 12In±20%, ensuring steadfast performance.
2. Rated Values: For a comprehensive understanding, please consult Table 2, which outlines the rated values of our circuit breakers, equipping you with all essential specifications.
3. Ambient Temperature: With a temperature at +40ºC, the over-current release action characteristics for distribution circuit breakers are delineated in Table 3. Refer to Table 4 for motor protection circuit breakers, ensuring optimal performance across various conditions.

Rated Value: Delve into the detailed specifications of the circuit breaker's rated value, engineered to provide reliable and efficient performance across diverse scenarios.

Model Pole Rated current (A) Rated
operating
voltage (V)
Rated
insulation
voltage (V)
Rated ultimate short - circuit breaking capacity (Icu) Flashover
distance(mm)
Test voltage (V) Icu (kA) Ics (kA)
DAM2L-63 3 10,16,20,25,
32,40,50,63
400 500 400×1.10 25 18 0
DAM2M-63 3,4 50 35
DAM2L-100 3,4 16,20,25,32,40,
50,63,80,100
400 800 30 22 ≤50
DAM2M-100 2,3,4 50 35
DAM2H-100 3 85 50
DAM2L-100 3,4 690 10 5
DAM2M-100 2,3,4 20 10
DAM2L-225 3,4 100,125,140,
160,180,200,225
400 800 35 25
TXCM1-225 2,3,4 50 35
DAM2H-225 3 85 50
DAM2L-225 3,4 690 10 5
DAM2M-225 2,3,4 20 10
DAM2L-400 3 225,250,315,
350,400
400 800 50 35 ≤100
DAM2M-400 3,4 65 42
DAM2H-400 3 100 65
DAM2L-400 3 690 15 8
DAM2M-400 3,4 20 10
DAM2L-630 3 400,500,630 400 800 50 35
DAM2M-630 3,4 65 42
DAM2H-630 3 100 65
DAM2L-630 3 6910 15 8
DAM2M-630 3,4 20 10
DAM2M-800 3 630,700,800 400 800 75 50
DAM2H-800 3 100 65
DAM2M-800 3 4690 30 15
DAM2-1250 3 800,1000,1250 400 800 85 42
DAM2-1250 3 690 25 12.5

Note: For 2-pole and 4-pole circuit breakers classified into L, M, and H types, each type's breaking index is equivalent to the M-type, ensuring uniform and consistent performance.

Inverse Time Breaking Action: Examine the characteristics of over-current release for power distribution, ensuring reliable protection when all poles are powered concurrently.

No. Test current I/In Set time Initial state
1 Conventional non-tripping current 1.05 2h(In>63A),1h(In≤63A) Cold
2 Conventional non-tripping current 1.30 2h(In>63A),1h(In≤63A) Immediately after Test 1

Instantaneous Action Characteristics: Distribution circuit breakers feature a setting value of 10In±20%, while motor protection circuit breakers maintain a robust 12In±20%, offering steadfast and reliable protection.

Inverse Time Breaking Action: Analyze the over-current release characteristics for motor protection, ensuring dependable safeguarding with simultaneous power across all poles.

No. I/In Set time Initial state Remark
1 1.0 >2h Cold  
2 1.2 ≤2h Immediately after Test 1  
3 1.5 ≤4min Cold 10≤n≤225
≤8min 225 < in ≤ 630
4 7.2 4s≤T≤10s Cold 10≤In≤225
6s≤T≤20s 225 < in ≤ 630

Accessories

1. Internal Accessories of Circuit Breakers

1.1 Shunt Release
Shunt Release Voltage: Designed for optimal efficiency with a rated control supply voltage of AC50Hz, 230V, 400V, or DC110V, 220V, 24V. It promises reliable circuit breaker functionality within a 70%~110% voltage range.

DC24V Shunt Release: Secure reliable functionality by following the specified maximum copper wire length, essential for optimal operation.

Rated control
supply voltage Uc(DC24V)/Conductor area
1.5mm² 2.5mm²
100%Uc
85%Uc
150m
100m
250m
160m

Design Recommendations: If specifications in the table are unmet, we suggest designing the shunt release control circuit as illustrated for assured efficacy.

1.2 Under-Voltage Release

Under-Voltage Operation: Unleash the power of supreme reliability with our meticulously engineered under-voltage release system. It has been designed to ensure your breaker maintains flawless operation even amidst voltage fluctuations ranging from a robust 70% to a low of 35% of the rated voltage. Immerse yourself in a realm of robust protection, offering unparalleled peace of mind.
Under-Voltage Protection: Embrace enhanced security with our state-of-the-art feature that vigilantly prevents unsafe circuit breaker closures when voltage levels drop below 35% of the rated threshold. This sophisticated system guarantees secure closures at levels above 85%, ensuring that each operation you undertake is both safe and consistently high-performing.
Closing Mechanism: Our cutting-edge under-voltage release mechanism is expertly crafted to ensure strong and reliable circuit breaker closure at supply voltages that exceed 85% of the rated value. This mechanism offers steadfast protection and ensures flawless operations, acting as an unrivaled safety net for your systems.
Under-Voltage Ratings: Our circuit breakers boast impressive ratings at AC50Hz for both 230V and 400V, ensuring consistent and dependable performance across a myriad of applications. With each use, you gain the assurance of peace of mind.
400V.
Special Note: Our circuit breakers, featuring a meticulously engineered under-voltage release, operate seamlessly only at the rated voltage. This precision ensures secure and reliable opening and closing operations, fortifying safety with every function.
normally.

1.3 Pre-Paid Meter Dedicated Release

The pre-paid meter dedicated release, rated at AC230/50Hz, delivers outstanding performance across a dynamic range of 65% to 110% of Ue. Notably, it facilitates a strategically timed circuit breaker opening between 0.5 and 2 seconds upon control disengagement. This offers exceptional safety and reliability, ensuring your peace of mind.

Wiring Diagram for Pre-Paid Meter Dedicated Release

1.4 Rated Values of Auxiliary Contacts and Alarm Contacts (Refer to Table 5)

Classification Conventional thermal current (Ith) Rated current when

 

AC 400V Ie(AC-15)

Rated current when

 

DC 220V Ie(DC-13)

Auxiliary contact 3 0.4 0.15
Alarm contact 3 0.3 0.15

a. Auxiliary Contact

b. Alarm Contact
Alarm contacts are meticulously crafted to remain inactive during normal operations. They transition seamlessly between normal open and normal closed states exclusively during free or fault tripping events, providing precise and timely alerts only when truly necessary.

2. External Accessories for Circuit Breakers

2.1 Motor Operating Mechanism: Uncover comprehensive specifications, including exact rated values and corresponding codes, meticulously presented in Table 6 for your convenience.

Category/Model DAM2-63. 125. 250 DAM2-400. 630. 800. 1250
Structure type Electromagnet Motor
AC voltage code AC50Hz,230V,400 AC50Hz,230V,400
DC voltage code DC110V,220V DC110V,220V

NOTE: To ensure consistent and safe operations, it is crucial to reset the circuit breaker after tripping via an electric operating mechanism, prior to any reclosing attempts.

Principle Diagram for Opening and Closing of DAM2-63,100,225 Electric Operating Mechanism (AC)

Principle Diagram for Opening and Closing of DAM2-400,630,800,1250 Electric Operating Mechanism (AC)

2.2 Installation Dimensions for Manual Operating Mechanism (Refer to Table 10)
Diagram of Handle Mounting Hole for DAM2-63~800

Total Height of Electric/Manual Operating Mechanism of Circuit Breaker (mm) (Refer to Table 12)

Model Total height of electric
operating mechanism H
Installation dimensions

 

of manual operating mechanism H

DAM2L-63 155 49
DAM2M/H-63 164 49
DAM2L-100 152 51
DAM2M/H-100 170 51
DAM2L-225 182 54
DAM2M/H-225 199 54
DAM2L/M/H-400 255 88
DAM2M/H-630 262 89
DAM2M/H-800 261 96
DAM2H-1250 290 103

Quick Selection Table for DAM2 Series Molded Case Circuit Breakers

Corresponding
letters
Function name Function corresponding to the model
a Model features DAM2 Molded Case

 

Circuit Breaker

b Frame rated current code 63A,100A,225A,

 

400A,630A,800A,

1250A

c Breaking capacity characteristic
code
L-standard breaking type;

 

M-second high breaking type;

H-high breaking type

d Operation mode code No code for handle operation;

 

P for electric operation;

Z for turning handle operation

e Pole 2-two poles;

 

3-three poles;

4-four poles

f Release name 2 Electromagnetic release;

 

3 Double release

g Accessory 00 Without accessory
08 Alarm contact
10 Shunt release
20 Auxiliary contact
30 Undervoltage release
40 Shunt release, Auxiliary contact
50 Shunt release, Undervoltage release
60 Two sets of auxiliary contacts
70 Auxiliary contact, Undervoltage release
18 Shunt release, Alarm contact
28 Auxiliary contact, Alarm contact
38 Undervoltage release, Alarm contact
48 Shunt release, Auxiliary contact, Alarm contact
58 Shunt release, Undervoltage release, Alarm contact
68 Two sets of auxiliary contacts, Alarm contact
78 Auxiliary contact, Undervoltage release, Alarm contact
10Y Pre-paid meter dedicated release
40Y Pre-paid meter dedicated release, Auxiliary contact
50Y Pre-paid meter dedicated release, Auxiliary contact, Undervoltage release
18Y Pre-paid meter dedicated release, Alarm contact
48Y Pre-paid meter dedicated release, Auxiliary contact, Alarm contact
58Y Pre-paid meter dedicated release, Undervoltage release, Alarm contact
h Application No code for distribution;

 

2 for motor protection

i Conventional products No code;

 

T for transparent cover products

j Amperage 10,16,20,25,32,63,80,100,125,160,180,200
,225,250,315,350,400,500,630,700,800,1000
,1250

Example: DAM2L-100 / 33102 63A represents an exemplary DAM2-type molded case circuit breaker. This model boasts a frame rated current of 100A, standard breaking capacity, handle operation, 3 poles, dual release, and shunt release. It is finely optimized for enhancing motor protection with a rated current of 63A.
For unmatched performance, it is essential to ensure that all selection, installation, and usage strictly adhere to the product manual or relevant national standards.
Note: The N-pole type of a 4P circuit breaker is classified into A-type and B-type. In the absence of specific specifications, the default designation is B-type.

Working Principle
The main contact of the molded case circuit breaker can be securely fastened either manually or electrically. Upon closure, the ingenious free release mechanism steadfastly locks the main contact, ensuring a firm and reliable closed position. The over...
The current trip coil and the thermal trip element are expertly configured in a strategic series alignment with the main circuit. This precise alignment is engineered to ensure optimal performance and reliability for your electrical systems, safeguarding against potential disruptions.
voltage
release
The coil and the power supply are elegantly configured in a harmonious parallel arrangement. This meticulous design guarantees seamless operation, enhancing the efficiency and dependability of your power systems.
Low Voltage Switchgear Circuit Breaker 250A with High Performance

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier