MCB with Busbar Function and 3ka Breaking Capacity for Industrial Use

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 0.65/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • MCB with Busbar Function and 3ka Breaking Capacity for Industrial Use
  • MCB with Busbar Function and 3ka Breaking Capacity for Industrial Use
  • MCB with Busbar Function and 3ka Breaking Capacity for Industrial Use
  • MCB with Busbar Function and 3ka Breaking Capacity for Industrial Use
  • MCB with Busbar Function and 3ka Breaking Capacity for Industrial Use
  • MCB with Busbar Function and 3ka Breaking Capacity for Industrial Use
Find Similar Products

Basic Info.

Model NO.
DAB6-63
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCB
Poles Number
1p, 2p.3p, 4p
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
ISO9001-2000, CE, CB, CCC, Asta, Semko, RoHS
Breaking Capacity(Ka)
3ka, 4.5ka, 6ka
Upper Terminal
with Busbar Function
Seal Function
Available
Transport Package
Carton
Specification
1, 2, 3, 4, 5, 6, 10, 16, 25, 32, 40, 50, 63A
Trademark
CDADA, OEM, ODM
Origin
Shanghai
HS Code
85362000
Production Capacity
100000PCS/Month

Product Description

Introduction
DAB6-63
are meticulously designed to safeguard distribution and group systems across various load conditions:
- Electric appliances and lighting systems featuring V characteristic switches, ensuring reliable operation;
- Moderate starting current drives, including compressors and fan groups, with robust C characteristic switches;
- High starting current drives, such as hoisting mechanisms and pumps, utilizing powerful D characteristic switches;
M
iniature circuit breaker DAB6-63
are perfectly suited for electrical distribution panels in both residential and public buildings, providing unmatched reliability.

Advantages
  • Features dual modes of short circuit protection, ensuring heightened safety standards.
  • Operates efficiently within a versatile temperature range from -40 to +50° C, making it suitable for various environments.
  • Enhanced engagement lever with an expanded contact area, delivering superior performance and longevity.
  • Specially designed notches on terminal clamps to effectively reduce thermal losses and enhance mechanical connection stability.
Technical Features
MCB DAB6-63
For protection of general power distribution (IEC/EN 60898-1)        
Poles 1P 2P 3P 4P
Electrical performance
Functions short circuit protection,overload protection,isolationg,control
Rated frequency  f   Hz 50-60Hz
Rated working voltage  Ue   V AC 230/400 400
Rated current  In A 6,10,16,20,25,32,40,50,63
Rated insulated voltage Ui  V 500
Impulse withstand voltage Uimp   kV 4
Instantaneous tripping type DAB6-63N B/C/D
DAB6-63H B/C/D
Rated short circuit Icn(kA)        DAB6-63N 4.5
DAB6-63H 6
Release type Thermal magnetic type
Service life(O~C) Mechanical  Actual value 20000
 Standard value 4000
Electrical  Actual value 8000
 Standard value 4000
Connection and installation
Protection degree IP20
Wire                                             mm² 1~35
Working temperature -5 ~+40ºC
Resistance to humidity and heat Class 2
Altitude above sea 2000
Relative humidity +20ºC , 90% ;+40ºC , 50%
Pollution degree 2
Installation environment Avoid obvious shock and vibration
Installation class Class II, Class III
Mounting DIN35 rail
Combination with accessories
Auxiliary contact Yes
Alarm contact Yes
Shunt release Yes
Undervoltage release Yes
Auxiliary contact+Alarm contact Yes
Dimensions(mm)                                            (WxHxL)                                                                                  a 17.5 35 52.5 70
b 80.2 80.2 80.2 80.2
c 76.5 76.5 76.5 76.5

MCB with Busbar Function and 3ka Breaking Capacity for Industrial UseMCB with Busbar Function and 3ka Breaking Capacity for Industrial UseMCB with Busbar Function and 3ka Breaking Capacity for Industrial UseMCB with Busbar Function and 3ka Breaking Capacity for Industrial UseMCB with Busbar Function and 3ka Breaking Capacity for Industrial UseMCB with Busbar Function and 3ka Breaking Capacity for Industrial UseMCB with Busbar Function and 3ka Breaking Capacity for Industrial UseMCB with Busbar Function and 3ka Breaking Capacity for Industrial UseMCB with Busbar Function and 3ka Breaking Capacity for Industrial UseMCB with Busbar Function and 3ka Breaking Capacity for Industrial UseMCB with Busbar Function and 3ka Breaking Capacity for Industrial UseMCB with Busbar Function and 3ka Breaking Capacity for Industrial Use

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed