Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 4/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker
  • Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker
  • Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker
  • Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker
  • Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker
  • Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker
Find Similar Products

Basic Info.

Model NO.
dabl-63 1p+n
Poles Number
1p+N
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CB, CCC
Release Type
Electronic Type
Rated Residual Current Motion
10mA,30mA,100mA,300mA
Residual Leakage Current Curve
a,AC,S Type
Transport Package
Carton
Specification
6, 10, 16, 20, 25, 32, 40, 50, 63A
Trademark
CDADA, OEM, ODM
Origin
Shanghai
HS Code
85362000
Production Capacity
200000PCS/Month

Product Description

DABL-63 6kA 10kA Electronic Residual Current Device RCBO Circuit Breaker

Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker

Introduction
The DABL-63 6kA 10kA Electronic Residual Current Circuit Breaker is a cutting-edge solution engineered by DaDa experts. This compact device offers reliable operation, precise protection, rapid response, and exceptional breaking capacity. Adhering to GB 10963 and IEC60898 standards, it ensures top-notch safety and performance.

These circuit breakers are ideal for protecting contactors, relays, and other electrical equipment against overload.

Main Functions: Short circuit protection, overload protection, and isolation.

Model
DABL-63 1P+N/2P RCBO Circuit Breaker
Rated current Rated frequency Rated operating voltage Rated residual current Rated insulation voltage Impulse withstand voltage Instantaneous trip type Rated breaking capacity W*H*L
6-63A 50-60Hz 230/400V 10,30,100,300A 500V 6KV B/C/D DABL-63 10KA, DABL-63 6KA 36/54mm*80.4mm*72mm
 

Technical Parameter of DABL-40 Electronic Residual Current Circuit Breaker
Protection Grade: IP20
Flame Retardant Grade: Grade 2
Mechanical Endurance: 12,000 cycles
Electrical Endurance: 6,000 cycles
Electric Wire Compatibility: 1~25mm2
Operating Temperature: -5~+40°C
Altitude: ≤2000 meters
Relative Humidity: At +20°C, ≤90%; at +40°C, ≤50%
Pollution Class: 2
Installation Environment: Avoid areas with significant shock and vibration.
Installation Grade: Grade II, Grade III

Installable Accessories for DABL-63 Electronic Residual Current Circuit Breaker
Available Accessories: Auxiliary contact, alarm contact, shunt trip, undervoltage trip, overvoltage trip.

Advantages

· Combines an electronic module for differential protection with an integrated DAB7-63 series circuit breaker.
· Provides superior protection against electric shock risks from direct contact with conducting parts.
· Features an independent contact position indicator.
· Operates efficiently across a wide temperature range: -25 to +40°C.
· Terminal clamp notches reduce thermal losses and enhance mechanical stability.
· Includes a 'TEST' button to verify device operation and connection accuracy.
· DABL dimensions are optimized to fit within a 2-modular item structure.
· Enhanced 6kA capability allows for the use of AVDTs as incoming protection switches.
 
Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker

 
Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker
 
Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker
 
Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker
 
Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker
 
Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker

 
Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker

 
Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker
 
Dabl-63 6ka 1p+N 100mA Electronic RCBO CB Approved Residual Current Circuit Breaker
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier