Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Manual Type |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Overview
Introducing the powerhouse of electrical protection, the Dada DAM3-1600 molded case circuit breaker excels with a remarkable rated current reaching up to an impressive 1600A. Expertly crafted to provide outstanding safeguarding for power distribution circuits, it performs effortlessly across an alternating current range of 50-60Hz, with a rated operating current of up to 1000A. This versatile, robust device is engineered to deliver top-tier safety for electric motors, offering reliable overload protection, infrequent starting capabilities, and unparalleled defense against short circuits and undervoltage conditions.
In a game-changing redefinition of performance standards, the DAM3 series takes a leap beyond the DAM1 series with its sleek, compact design and superior breaking capacity. Meticulously designed for efficiency, these circuit breakers not only maximize space utilization but also deliver impressive energy savings, setting a revolutionary benchmark in the industry.
Electrical parameters of DAM3-1600 molded case circuit breakerRated current of frame size Inm [A] | 1600 | |||
Rated current [A] | 1000 1250 1600 | |||
Number of poles | 3 / 4 | |||
Rated operating voltage | (AC)50-60HZ [V] | 400/690 | ||
DC [V] | 250/1000 | |||
Rated impulse withstand voltage Uimp [KV] | 8 | |||
Rated insulation voltage Ui[V] | 750 | |||
Test voltage at industrial frequency for 1 min [V] | 3000 | |||
Rated ultimate short-circuit breaking capacity Icu [KA] | S | H | G | |
(AC)50-60HZ 220/230V [KA] | 80 | 105 | 130 | |
(AC)50-60HZ 400/415V [KA] | 55 | 70 | 100 | |
(AC)50-60HZ 690V[KA] | 20 | 25 | 30 | |
(DC)250V-2 Poles in series | 50 | 65 | 80 | |
(DC)500V-2 Poles in series | 22 | 30 | 40 | |
(DC)750V-4 Poles in series | 42 | 55 | 68 | |
(DC)1000V-4 Poles in series | 35 | 45 | 55 | |
Rated service short-circuit breaking capacity, Ics [KA] | ||||
(AC)50-60HZ 220/230V [%Icu] | 60% | 60% | 60% | |
(AC)50-60HZ 400/415V [%Icu] | 60% | 60% | 60% | |
(AC)50-60HZ 690V[%Icu] | 60% | 60% | 60% | |
Category of utilisation(EN 60947-2) | A | |||
Isolation condition | Bitmap | |||
Reference standard | IEC/EN 60947-2/GB 14048.2 | |||
Interchangeability | Bitmap | |||
Versions | Fixed | Bitmap | ||
Plug-in | Bitmap | |||
Draw-out | Bitmap |
Endurance | Total cycles | 5000 |
Electrical endurance | 1000 | |
Mechanical endurance | 4000 | |
Basic dimensjons-fixed version |
3/4 Poies W[mm] | 210/280 |
3/4 Poies H[mm] | 140 | |
H1[mm] | 196 | |
3/4 Poies L[mm] | 328 |
Introduction
Experience intelligent safety with the DAM3-1600 molded case circuit breaker, an advanced device engineered to automatically disconnect power when current exceeds its pre-set release threshold. This cutting-edge system is housed in a molded case crafted from resilient plastic insulator, constructing the frame and efficiently insulating the conductor alongside metal grounding components, ensuring safe and reliable operation.
Working principle
Precision meets protection in the DAM3-1600 molded case circuit breaker, featuring a main contact controllable both manually and through electric closing. Once secured in the closed position by a reliable free release mechanism, it stands vigilant. The overcurrent trip coil and thermal trip element, intricately linked in series with the main circuit, provide rapid response to overcurrent, while the undervoltage trip coil, strategically connected in parallel with the power supply, guarantees unwavering protection against voltage drops.