• Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO
  • Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO
  • Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO
  • Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO

Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: Arc Chamber
Installation: Fixed
Structure: MCB
Samples:
US$ 4/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Shanghai, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)

Basic Info.

Model NO.
DABL-63
Poles Number
1p+N,3p+N
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CB, CCC
Transport Package
Carton
Specification
6, 10, 16, 20, 25, 32, 40, 50, 63A
Trademark
CDADA, OEM, ODM
Origin
Shanghai
HS Code
85362000
Production Capacity
200000PCS/Month

Product Description

DABL-63 6kA 10kA Electronic Residual Current Device RCBO Circuit Breaker

Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO

Introduction
The DABL-63 6kA 10kA electronic residual current circuit breaker is designed by Dada engineers for stable operation, precise protection, short opening time, and a high breaking capacity index, all in one small device. The circuit breakers are also produced according to GB 10963 and IEC60898 standards.

The circuit breakers are commonly installed for the overload protection of contactors, relays, and other electrical equipment.

Main functions: short circuit protection, overload protection and isolation.

Model
DABL-63 1P+N/2P RCBO Circuit Breaker
Rated current Rated frequency Rated operating voltage Rated residual current Rated insulation voltage Impulse withstand voltage Instantaneous trip type Rated breaking capacity W*H*L
6-63A 50-60Hz 230/400V 10,30,100,300A 500V 6KV B/C/D DABL-63 10KA, DABL-63 6KA 36/54mm*80.4mm*72mm


DABL-63 3P+N/4P RCBO Circuit Breaker
Rated current Rated frequency Rated operating voltage Rated residual current Rated insulation voltage Impulse withstand voltage Instantaneous trip type Rated breaking capacity W*H*L
6-63A 50-60Hz 230/400V 10,30,100,300A 500V 6KV B/C/D DABL-63 10KA, DABL-63 6KA 72/90mm*80.4mm*72mm


DABL-63 2P RCBO Circuit Breaker
Rated current Rated frequency Rated operating voltage Rated residual current Rated insulation voltage Impulse withstand voltage Instantaneous trip type Rated breaking capacity W*H*L
6-63A 50-60Hz 230/400V 10,30,100,300A 500V 6KV B/C/D DABL-63 10KA, DABL-63 6KA 54mm*95mm*72mm

Inquiry Form
DABL-63 3P+N/4P RCBO Circuit Breaker
Rated current Rated frequency Rated operating voltage Rated residual current Rated insulation voltage Impulse withstand voltage Instantaneous trip type Rated breaking capacity W*H*L
6-63A 50-60Hz 230/400V 10,30,100,300A 500V 6KV B/C/D DABL-63 10KA, DABL-63 6KA 72/90mm*95mm*72mm
 

Technical parameter of DABL-40 electronic residual current circuit breaker
Protection grade: IP20
Flame retardant grade: grade2
Endurance (mechanical): 12,000
Endurance (electrical): 6,000
Electric wire: 1~25mm2
Operating temperature: -5~+40ºC
Altitude: ≤2000
Relative humidity: +20ºC, ≤90%; +40ºC, ≤50%
Class of pollution: 2
Installation environment: Avoid obvious shock and vibration
Installation grade: grade II, grade III

Installable accessories of DABL-63 electronic residual current circuit breaker
Auxiliary contact, alarm contact, shunt trip, undervoltage trip, overvoltage trip

Advantages

·  Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series.
·  The most subtle electric shock hazard protection in case of direct contact with conducting parts.
·  Independent contact position indicator.
·  Wide range of operating temperatures from -25 to +40° С.
·  Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection.
·  "TEST" button for checking the device's operation and accuracy of connection.
·  DABL dimensions correspond to 2-modular item at the expense of constructive elements placement.
·  Boosted capability of 6 kA provides for installing AVDTs as incoming protection switches.

Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO
Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO


Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO
Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO
Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO
Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO
Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO



Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO

Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO
Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now