160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 14/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • 160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
  • 160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
  • 160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
  • 160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
  • 160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
Find Similar Products

Basic Info.

Model NO.
DAM1-160
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
ISO9001-2000, CE, CB, CCC, Kema, Asta, Semko, RoHS
Cover
BMC Unflaming Material
Base
BMC Unflaming Material
Terminal
with Terminal Box
Neutral Pole
Left Side
Rated Insulation Voltage
1000V
Rated Operation Voltage
400/415V
Transport Package
Carton
Specification
16, 20, 25, 32, 40, 50, 70, 80, 100, 125, 160A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
8536200000
Production Capacity
40000PCS/Month

Product Description


Introduction

The highly efficient DAM1 series circuit breakers are meticulously crafted to facilitate seamless current conduction under standard conditions while ensuring robust protection by disconnecting circuits in the event of short circuits, overloads, or other hazardous interruptions. These breakers are perfectly suited for integration in electrical systems operating at a maximum voltage of 400V across a wide range of rated currents from 12.5A to an impressive 1600A.

These products thoroughly comply with the stringent standards set by EN 60947-1 and EN 60947-2.


Thermal-Magnetic Circuit Breakers:

Thermal protection function: (Designed to safeguard systems under overload conditions)
The integral bimetallic strip, responsible for thermal protection, ingeniously integrates two metals with distinct thermal expansion rates. Upon heating, the bimetallic strip gracefully bends towards the metal with a lower expansion rate, thereby engaging a mechanism that facilitates the breaker's operation. The rate of this bending directly correlates with the current flowing through the breaker, as elevated current levels generate additional heat. Consequently, this sophisticated mechanism enables overcurrent protection, ensuring optimal performance when load currents exceed the rated thresholds.
Magnetic protection function: (Engineered for safeguarding against short circuit conditions) An essential capability of this breaker is to provide unwavering protection to the connected circuit against incidents of short circuits. Such scenarios may arise from the inadvertent contact between phases or between a phase and the ground. Given that extremely high currents may traverse through the cables during a short circuit, it is imperative for the system's energy to be swiftly disrupted due to the thermal protection. The breaker must execute an instant disconnection to secure the load it is associated with. This critical function is carried out by a mechanical opening mechanism that efficiently activates in response to the magnetism generated by the magnetic field induced by the short circuit current.
 
Thermal-Magnetic fixed type Circuit Breakers  
Model DAM1-160
Breaking Capacity Code B N S
Rated Current of Frame size- Inm                                                                    (A) 160A
Rated Current-In(40,50 or 55ºC)                                                                      (A) 10- 12,5-16-20 - 25 - 32 - 40  - 50 - 63 - 80 - 100 -125 - 160(150)A
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz                                                    (V) 750V
Rated operation Voltage  -Ue(a.c.) 50-60Hz                                                    (V) 400/415V
Number of Pole 3P / 4P
Rated ultimate short Circuit breaking Capacity  kA  Icu AC400V/50Hz O-CO          (KA) 25 35 50
Rated service short Circuit breaking Capacity  kA  Ics AC400V/50Hz O-CO-CO     (KA) 12.5 26.25 37.5
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO         (KA) 41/0.3 73.5/0.25 110/0.25
Rated impulse withstand Voltage -Uimp                                                                            (V) 8000
Dielectric Propery (V) 3000
lonization distance                                                                                                              (mm) 30/0
Endurance Total Cycles 8000
Electrical Life 1000
Mechanical Life 7000
Over Current trip Thermal and Magnetic release fix type
Category (EN 60947-2/IEC 60947-2) Main circuit A/0
Auxiliary circuit AC-15
Under Voltage Release 
Shunt Release
Auxiliary Contact
Alarm Contact
Auxiliary Contact and Alarm Contact
Handle Operation Mechanism
Electrical Operastion Mechanism 
DIN clips
Terminal cover    
Phase seperator    
Extention Handle     -
  W (mm) 3P 90
4P 120
L (mm) 3P 120
4P 120
H (mm) 3P 70
4P 70
Weight Fixed version 3P/4P 1.2/1.6
Plug-in version 3P/4P 1.4/1.8
Draw out version 3P/4P -


160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material

160A 3p MCCB Moulded Case Circuit Breaker with Unflaming Material
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier