Dam2 Moulded Case Breaker 250A Low Voltage Circuit MCCB

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Dam2 Moulded Case Breaker 250A Low Voltage Circuit MCCB
  • Dam2 Moulded Case Breaker 250A Low Voltage Circuit MCCB
  • Dam2 Moulded Case Breaker 250A Low Voltage Circuit MCCB
  • Dam2 Moulded Case Breaker 250A Low Voltage Circuit MCCB
  • Dam2 Moulded Case Breaker 250A Low Voltage Circuit MCCB
  • Dam2 Moulded Case Breaker 250A Low Voltage Circuit MCCB
Find Similar Products

Basic Info.

Model NO.
CM1-125
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Transport Package
Carton
Specification
12.5, 16, 20, 25, 32, 40, 50, 70, 80, 100A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
85362000
Production Capacity
10000PCS/Month

Product Description

Dam2 Moulded Case Breaker 250A Low Voltage Circuit MCCB


Introducing the DAM2 series Moulded Case Circuit Breaker, an epitome of innovation, meticulously designed using state-of-the-art international technology. These trailblazing breakers feature an impressively compact structure, superior breaking capacity, minimal arc-over distance, and a resilient shake-proof design. This makes them the ideal solution for diverse applications across both land and maritime environments.

Application

The DAM2 (CM1) series circuit breaker is a powerhouse, boasting a rated insulation voltage of 800V. It's expertly crafted for AC distribution networks at 50Hz/60Hz, with a rated working voltage reaching up to 690V and a rated current up to 1250A. Perfect for power distribution and circuit protection, it safeguards equipment from overloads, short-circuits, under-voltage, and more. It accommodates infrequent circuit conversions and motor starts, delivering unmatched adaptability. Install it vertically or horizontally-it's versatile enough for both. Recognized for isolation by the symbol " ", the DAM2 MCCB aligns with IEC60947-2 standards for low-voltage switchgear and control equipment, reaffirming its excellence in circuit breakers.

Dam2 Moulded Case Breaker 250A Low Voltage Circuit MCCBDam2 Moulded Case Breaker 250A Low Voltage Circuit MCCB

Normal operating conditions

1. Ambient air temperature: Maintain between -5ºC to +40ºC, ensuring that the daily average does not surpass +35ºC.
2. Altitude: Ensure installation site altitude remains within 2000 meters to optimize performance.
3. Atmospheric conditions: At +40ºC, relative humidity shouldn't exceed 50%, yet higher humidity is acceptable at reduced temperatures. The maximum average relative humidity is 90%, with a minimum average monthly temperature of +25ºC, accounting for possible condensation due to temperature fluctuations.
4. Pollution Degree: 3.

Selection of instructions

Classified by pole types:
Type A: N-pole without over-current release components, stays continuously connected, and does not operate alongside the other three poles.
Type B: N-pole without over-current release components, operates in unison with the other three poles (N-pole activates prior to deactivation).
Type C: N-pole with over-current release components, functions along with the other three poles (N-pole activates before deactivation).

Classified by rated current of over-current release:
DAM2-63 MCCB Available in an extensive selection of nine ratings: 6, 10, 16, 20, 25, 32, 40, 50, and 63 A.
DAM2-100 MCCB Available in nine versatile ratings: 16, 20, 25, 32, 40, 50, 63, 80, and 100 A.
DAM2-250 MCCB Available in a solid range of seven ratings: 100, 125, 140, 160, 180, 200, 225, and 250 A.
DAM2-400 MCCB Available in five distinct ratings: 225, 250, 315, 350, and 400 A.
DAM2-630 MCCB Available in three robust ratings: 400, 500, and 630 A.
DAM2-800 MCCB Available in three formidable ratings: 630, 700, and 800 A.
DAM2-1250 MCCB, available in three commanding ratings: 800, 1000, and 1250 A.
Remark: Please note that our 6A version is exclusively available in the electromagnetic (instantaneous) type. Due to specification constraints, it is not recommended for general use.
Wiring Options: Experience versatile installation with our selection of front-of-board, back-of-board, or insertion type wiring. Tailor your setup to meet your exact needs.
Over-Current Release Patterns: Choose from our thermodynamic-electromagnetic (dual) type or electromagnetic (instantaneous) type. Each option is crafted to fulfill a variety of requirements, ensuring optimal performance.
Outfit Options: Customize your solution by selecting either circuit breakers with outfit or without. This flexibility ensures you meet specific application demands effortlessly.
Outfit Details: Elevate your setup with our extensive range of accessories. Inner accessories include shunt release, under-voltage release, auxiliary contact, and alarm contact. Meanwhile, our outer accessories feature advanced turning handle operation mechanisms and power-driven operation mechanisms, guaranteeing seamless functionality.
Breaking Capacity: Discover our diverse range of breaking capacities, including L-standard breaking type, M-second high breaking type, and H-high breaking type, designed to accommodate a spectrum of applications with precision.

Dam2 Moulded Case Breaker 250A Low Voltage Circuit MCCBDam2 Moulded Case Breaker 250A Low Voltage Circuit MCCB


Technical Parameters

1. Instantaneous Action Characteristics: For distribution circuit breakers, the setting value is 10In±20%. For the DAM2-1250 model, it is 7In±20%. For motor protection circuit breakers, enjoy a setting value of 12In±20%, ensuring robust performance.
2. Rated Values: For comprehensive specifications, please refer to Table 2, which details the rated values of our circuit breakers, ensuring you have all the necessary information at your fingertips.
3. Ambient Temperature: At a temperature of +40ºC, the over-current release action characteristics are detailed in Table 3 for distribution circuit breakers, and in Table 4 for motor protection circuit breakers, ensuring optimal operation in varied conditions.

Rated Value: Explore the detailed specifications of the rated value of the circuit breaker, designed to provide reliable and efficient operation in any scenario.

Model Pole Rated current (A) Rated
operating
voltage (V)
Rated
insulation
voltage (V)
Rated ultimate short - circuit breaking capacity (Icu) Flashover
distance(mm)
Test voltage (V) Icu (kA) Ics (kA)
DAM2L-63 3 10,16,20,25,
32,40,50,63
400 500 400×1.10 25 18 0
DAM2M-63 3,4 50 35
DAM2L-100 3,4 16,20,25,32,40,
50,63,80,100
400 800 30 22 ≤50
DAM2M-100 2,3,4 50 35
DAM2H-100 3 85 50
DAM2L-100 3,4 690 10 5
DAM2M-100 2,3,4 20 10
DAM2L-225 3,4 100,125,140,
160,180,200,225
400 800 35 25
TXCM1-225 2,3,4 50 35
DAM2H-225 3 85 50
DAM2L-225 3,4 690 10 5
DAM2M-225 2,3,4 20 10
DAM2L-400 3 225,250,315,
350,400
400 800 50 35 ≤100
DAM2M-400 3,4 65 42
DAM2H-400 3 100 65
DAM2L-400 3 690 15 8
DAM2M-400 3,4 20 10
DAM2L-630 3 400,500,630 400 800 50 35
DAM2M-630 3,4 65 42
DAM2H-630 3 100 65
DAM2L-630 3 6910 15 8
DAM2M-630 3,4 20 10
DAM2M-800 3 630,700,800 400 800 75 50
DAM2H-800 3 100 65
DAM2M-800 3 4690 30 15
DAM2-1250 3 800,1000,1250 400 800 85 42
DAM2-1250 3 690 25 12.5

Note: For our 2-pole and 4-pole circuit breakers, classified into L, M, and H types, the breaking index for all categories is equivalent to that of the M-type. This uniformity ensures consistent performance.

Inverse Time Breaking Action: Discover the characteristics of over-current release for power distribution, effective when all poles are powered simultaneously, ensuring reliable protection.

No. Test current I/In Set time Initial state
1 Conventional non-tripping current 1.05 2h(In>63A),1h(In≤63A) Cold
2 Conventional non-tripping current 1.30 2h(In>63A),1h(In≤63A) Immediately after Test 1

Instantaneous Action Characteristics: Distribution circuit breakers offer a setting value of 10In±20%, while motor protection circuit breakers are set at 12In±20%, providing robust and reliable performance.

Inverse Time Breaking Action: Explore the characteristics of over-current release for motor protection, effective when all poles are powered simultaneously, delivering dependable safeguarding.

No. I/In Set time Initial state Remark
1 1.0 >2h Cold  
2 1.2 ≤2h Immediately after Test 1  
3 1.5 ≤4min Cold 10≤n≤225
≤8min 225 < in ≤ 630
4 7.2 4s≤T≤10s Cold 10≤In≤225
6s≤T≤20s 225 < in ≤ 630

Accessories

1. Internal Accessories of Circuit Breakers

1.1 Shunt Release
Shunt Release Voltage: Designed to operate efficiently with a rated control supply voltage of AC50Hz, 230V, 400V, or DC110V, 220V, 24V. It guarantees reliable circuit breaker operation within a 70%~110% voltage range.

DC24V Shunt Release: Ensure reliable operation by adhering to the specified maximum length of copper wire, crucial for optimal performance.

Rated control
supply voltage Uc(DC24V)/Conductor area
1.5mm² 2.5mm²
100%Uc
85%Uc
150m
100m
250m
160m

Design Recommendations: Should the specifications outlined in the above table not be met, we recommend designing the shunt release control circuit as per the provided figure for guaranteed efficacy.

1.2 Under-Voltage Release

Under-Voltage Operation: The under-voltage release ensures reliable breaker operation when supply voltage dips to 70%-35% of the rated voltage, offering dependable protection.
Under-Voltage Protection: This feature prevents circuit breaker closure when voltage falls below 35% of the rated level, and assures closure above 85%, ensuring safe and consistent functionality.
Closing Mechanism: The under-voltage release mechanism ensures secure circuit breaker closure at supply voltages exceeding 85% of the rated value, safeguarding operations.
Under-Voltage Ratings: With ratings at AC50Hz, 230V, 400V, expect reliable performance across various applications, delivering peace of mind.
400V.
Special Note: Our circuit breakers equipped with under-voltage release operate correctly only at the rated voltage, ensuring safe and dependable opening and closing.
normally.

1.3 Pre-Paid Meter Dedicated Release

The rated operating voltage Ue of the pre-paid meter dedicated release is AC230/50Hz, ensuring exemplary performance across a wide spectrum from 65% to 110% of Ue. Remarkably, upon disengagement of the control (Ctrl), the circuit breaker will initiate a strategically delayed opening, spanning from 0.5 to 2 seconds. This feature is ingeniously designed to deliver unparalleled safety and reliability.

Wiring Diagram for Pre-Paid Meter Dedicated Release

1.4 Rated Values of Auxiliary Contacts and Alarm Contacts (Refer to Table 5)

Classification Conventional thermal current (Ith) Rated current when

 

AC 400V Ie(AC-15)

Rated current when

 

DC 220V Ie(DC-13)

Auxiliary contact 3 0.4 0.15
Alarm contact 3 0.3 0.15

a. Auxiliary Contact

b. Alarm Contact
Alarm contacts are meticulously crafted to remain inactive under normal operational circumstances. They transition between normal open and normal closed states only when the circuit breaker experiences free tripping or fault tripping, thus ensuring precise and timely alerts solely when required.

2. External Accessories for Circuit Breakers

2.1 Motor Operating Mechanism: Detailed specifications, including rated values and corresponding codes, are outlined in Table 6.

Category/Model DAM2-63. 125. 250 DAM2-400. 630. 800. 1250
Structure type Electromagnet Motor
AC voltage code AC50Hz,230V,400 AC50Hz,230V,400
DC voltage code DC110V,220V DC110V,220V

NOTE: Following the tripping of the circuit breaker with an electric operating mechanism, it is imperative for the mechanism to reset the circuit breaker prior to any attempt at reclosing.

Principle Diagram for Opening and Closing of DAM2-63,100,225 Electric Operating Mechanism (AC)

Principle Diagram for Opening and Closing of DAM2-400,630,800,1250 Electric Operating Mechanism (AC)

2.2 Installation Dimensions for Manual Operating Mechanism (Refer to Table 10)
Diagram of Handle Mounting Hole for DAM2-63~800

Total Height of Electric/Manual Operating Mechanism of Circuit Breaker (mm) (Refer to Table 12)

Model Total height of electric
operating mechanism H
Installation dimensions

 

of manual operating mechanism H

DAM2L-63 155 49
DAM2M/H-63 164 49
DAM2L-100 152 51
DAM2M/H-100 170 51
DAM2L-225 182 54
DAM2M/H-225 199 54
DAM2L/M/H-400 255 88
DAM2M/H-630 262 89
DAM2M/H-800 261 96
DAM2H-1250 290 103

Quick Selection Table for DAM2 Series Molded Case Circuit Breakers

Corresponding
letters
Function name Function corresponding to the model
a Model features DAM2 Molded Case

 

Circuit Breaker

b Frame rated current code 63A,100A,225A,

 

400A,630A,800A,

1250A

c Breaking capacity characteristic
code
L-standard breaking type;

 

M-second high breaking type;

H-high breaking type

d Operation mode code No code for handle operation;

 

P for electric operation;

Z for turning handle operation

e Pole 2-two poles;

 

3-three poles;

4-four poles

f Release name 2 Electromagnetic release;

 

3 Double release

g Accessory 00 Without accessory
08 Alarm contact
10 Shunt release
20 Auxiliary contact
30 Undervoltage release
40 Shunt release, Auxiliary contact
50 Shunt release, Undervoltage release
60 Two sets of auxiliary contacts
70 Auxiliary contact, Undervoltage release
18 Shunt release, Alarm contact
28 Auxiliary contact, Alarm contact
38 Undervoltage release, Alarm contact
48 Shunt release, Auxiliary contact, Alarm contact
58 Shunt release, Undervoltage release, Alarm contact
68 Two sets of auxiliary contacts, Alarm contact
78 Auxiliary contact, Undervoltage release, Alarm contact
10Y Pre-paid meter dedicated release
40Y Pre-paid meter dedicated release, Auxiliary contact
50Y Pre-paid meter dedicated release, Auxiliary contact, Undervoltage release
18Y Pre-paid meter dedicated release, Alarm contact
48Y Pre-paid meter dedicated release, Auxiliary contact, Alarm contact
58Y Pre-paid meter dedicated release, Undervoltage release, Alarm contact
h Application No code for distribution;

 

2 for motor protection

i Conventional products No code;

 

T for transparent cover products

j Amperage 10,16,20,25,32,63,80,100,125,160,180,200
,225,250,315,350,400,500,630,700,800,1000
,1250

Example: DAM2L-100 / 33102 63A denotes a DAM2-type molded case circuit breaker. This model boasts a frame rated current of 100A, standard breaking capacity, handle operation, 3 poles, double release, with shunt release, optimized for motor protection with a rated current of 63A.
Selection, installation, and use must strictly adhere to the product manual or relevant national standards to guarantee unparalleled performance.
Note: The N-pole type of a 4P circuit breaker is classified into A-type and B-type. In instances where specification is absent, the default designation is B-type.

Working Principle
The main contact of the molded case circuit breaker can be secured either manually or electrically. Upon closure, the free release mechanism ingeniously locks the main contact in a steadfast closed position. The over
current trip coil and the thermal trip element are strategically aligned in series with the main circuit, whereas the under
voltage
release
coil and the power supply are harmoniously configured in parallel.
Dam2 Moulded Case Breaker 250A Low Voltage Circuit MCCB

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.