Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Manual Type |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Compared to the DAM1 series, the DAM3 series have been meticulously designed to feature a more compact form factor, higher breaking capacity, and superior energy efficiency, ensuring optimal performance and sustainability.
Electrical parameters of DAM3-250 molded case circuit breakerRated current of frame size Inm [A] | 250 | ||||
Rated current [A] | 100-250 | 100-225 | |||
Number of poles | 2 / 3 / 4 | ||||
Rated operating voltage | (AC)50-60HZ [V] | 400/690 | |||
DC [V] | 250/1000 | ||||
Rated impulse withstand voltage Uimp [KV] | 8 | ||||
Rated insulation voltage Ui [V] | 750 | ||||
Test voltage at industrial frequency for 1 min [V] | 3000 | ||||
Rated ultimate short-circuit breaking capacity Icu [KA] | B | C | N | S | |
(AC)50-60HZ 220/230V [KA] | 30 | 36 | 50 | 75 | |
(AC)50-60HZ 400/415V [KA] | 18 | 25 | 36 | 50 | |
(AC)50-60HZ 690V [KA] | 6 | 8 | 12 | 15 | |
(DC)250V-2 Poles in series | 18 | 22 | 30 | 40 | |
(DC)500V-2 Poles in series | 9 | 12 | 15 | 20 | |
(DC)750V-4 Poles in series | 16 | 18 | 22 | 30 | |
(DC)1000V-4 Poles in series | 13 | 15 | 18 | 25 | |
Rated service short-circuit breaking capacity, Ics [KA] | |||||
(AC)50-60HZ 220/230V [%Icu] | 60% | 60% | 60% | 50% | |
(AC)50-60HZ 400/415V [%Icu] | 60% | 60% | 60% | 50% | |
(AC)50-60HZ 690V [%Icu] | 60% | 60% | 60% | 50% | |
category of utilization (EN 60947-2) | A | ||||
Isolation condition | Bitmap | ||||
Reference standard | IEC/EN 60947-2/GB 14048.2 | ||||
Interchangeability | Bitmap | ||||
Versions | Fixed | Bitmap | |||
Plug-in | Bitmap | ||||
Draw-out | - |
Endurance | Total cycles | 10000 | |
Electrical endurance | 1500 | ||
Mechanical endurance | 8500 | ||
Basic dimensions-fixed version |
3/4 Poies W[mm] | 70(2P) /104 /139 | |
3/4 Poies H[mm] | 59 | 62.5 | |
H1[mm] | 78.5 | 82 | |
3/4 Poies L[mm] | 139 |
Introduction
The DAM3-250 molded case circuit breaker is engineered to automatically disconnect the current once it surpasses the preset release threshold. The term 'molded case' pertains to the robust plastic insulator that forms the frame of the device, ensuring insulation between the conductor and the metal grounding component.
Working principle
The operation of the DAM3-250 molded case circuit breaker involves manual or electric closing of the main contact. Once closed, the free release mechanism secures the main contact in the closed position. The overcurrent trip coil and thermal trip element are integrated in series with the main circuit, while the undervoltage trip coil is connected in parallel with the power supply, ensuring comprehensive protection.