Cdada 250A Moulded Case Switch for Fixed Type Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 10/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Cdada 250A Moulded Case Switch for Fixed Type Circuit Breaker
  • Cdada 250A Moulded Case Switch for Fixed Type Circuit Breaker
  • Cdada 250A Moulded Case Switch for Fixed Type Circuit Breaker
  • Cdada 250A Moulded Case Switch for Fixed Type Circuit Breaker
  • Cdada 250A Moulded Case Switch for Fixed Type Circuit Breaker
  • Cdada 250A Moulded Case Switch for Fixed Type Circuit Breaker
Find Similar Products

Basic Info.

Model NO.
CM1-125
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Transport Package
Carton
Specification
12.5, 16, 20, 25, 32, 40, 50, 70, 80, 100A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
85362000
Production Capacity
10000PCS/Month

Product Description

Cdada 250A Moulded Case Switch for Fixed Type Circuit Breaker


Discover the groundbreaking DAM2 series Moulded Case Circuit Breaker, an epitome of cutting-edge engineering infused with state-of-the-art global technology. Designed to perfection, these circuit breakers boast a sleek, compact form, remarkable breaking capacity, minimal arc-over distance, and a sturdy shake-proof construction. Ideal for both land and sea applications, they stand as the pinnacle of reliable performance.

Application

The powerhouse DAM2 (CM1) series circuit breaker is meticulously crafted with a rated insulation voltage of 800V. Tailored for AC distribution networks operating at 50Hz/60Hz, it efficiently manages a rated working voltage of up to 690V and handles current up to 1250A. Engineered to excel, it distributes power while protecting circuits and equipment from overloads, short-circuits, under-voltage, and other potential hazards. With its capability to support infrequent circuit conversions and motor starts, it offers exceptional versatility in installation options, whether vertical or horizontal. Recognized for its isolation capability, symbolized by ' ', the DAM2 MCCB adheres to the rigorous standards of IEC60947-2 for low-voltage switchgear and control equipment, Part 2: circuit breakers.

Cdada 250A Moulded Case Switch for Fixed Type Circuit BreakerCdada 250A Moulded Case Switch for Fixed Type Circuit Breaker

Normal operating conditions

1. Ambient air temperature: Maintain a range from -5ºC to +40ºC, ensuring that the daily average does not surpass +35ºC.
2. Altitude: Confirm that the installation site remains below an altitude of 2000 meters.
3. Atmospheric conditions: At a maximum temperature of +40ºC, the relative humidity should not exceed 50%. Increased humidity levels are permissible at lower temperatures, with a maximum average relative humidity of 90% and a minimum average monthly temperature of +25ºC, accommodating temperature-induced condensation on the product's surface.
4. Pollution Degree: Level 3.

Selection of instructions

Classified by pole types:
Type A: N-pole without over-current release components, continuously connected, and does not operate with the other three poles.
Type B: N-pole without over-current release components, operates concurrently with the other three poles (N-pole activates prior to deactivation).
Type C: N-pole with over-current release components, operates in conjunction with the other three poles (N-pole activates before deactivation).

Classified by rated current of over-current release:
DAM2-63 MCCB Available in nine ratings: 6, 10, 16, 20, 25, 32, 40, 50, 63 A, catering to a wide array of needs.
DAM2-100 MCCB Available in nine ratings: 16, 20, 25, 32, 40, 50, 63, 80, 100 A, ensuring adaptability for diverse applications.
DAM2-250 MCCB Available in seven ratings: 100, 125, 140, 160, 180, 200, 225, 250 A, providing flexibility for various requirements.
DAM2-400 MCCB Available in five ratings: 225, 250, 315, 350, 400 A, engineered to meet high-performance expectations.
DAM2-630 MCCB Available in three ratings: 400, 500, 630 A, crafted for robust, demanding environments.
DAM2-800 MCCB Available in three robust ratings of 630, 700, and 800 Amperes, the Cdada 250A Moulded Case Switch is expertly designed to cater to your higher capacity requirements, ensuring your systems operate with uncompromised efficiency.
DAM2-1250 MCCB offers unparalleled power and protection, available in three dynamic ratings: 800, 1000, and 1250 Amperes. Experience ultimate reliability and safety with these meticulously engineered circuit solutions.
Remark: Please be advised that the 6A version is restricted to electromagnetic (instantaneous) type only, due to its specification limitations. It is advisable to select with caution to guarantee optimal performance and system integrity.
Wiring Options: Personalize your installation with an extensive selection of wiring configurations, including front-of-board, back-of-board, or insertion types. These adaptable solutions ensure seamless integration into diverse setups, offering unparalleled installation flexibility.
Over-Current Release Patterns: Our circuit breakers feature a dual-type thermodynamic-electromagnetic model and an instantaneous-only electromagnetic model, crafted to suit a broad spectrum of applications with exceptional precision and unwavering reliability.
Outfit Options: Tailor your circuit breaker to your precise specifications by selecting options with or without outfit enhancements, guaranteeing a perfect fit for your electrical infrastructure and maximizing system performance.
Outfit Details: Elevate the functionality of your circuit breaker with our comprehensive range of inner accessories, including shunt and under-voltage releases, as well as auxiliary and alarm contacts. For outer accessories, choose from manual turning handles to advanced power-driven mechanisms, ensuring full control and versatility.
Breaking Capacity: Discover our extensive range of breaking capacity options, including L-standard, M-second high, and H-high breaking types. These selections are crafted to meet the varied demands of your applications, ensuring optimal circuit protection and longevity.

Cdada 250A Moulded Case Switch for Fixed Type Circuit BreakerCdada 250A Moulded Case Switch for Fixed Type Circuit Breaker


Technical Parameters

1. Instantaneous Action Characteristics: Our distribution circuit breakers are engineered with a setting value of 10In±20%, while the DAM2-1250 model boasts a precision configuration of 7In±20%. Motor protection circuit breakers maintain rigorous settings of 12In±20%, ensuring peak performance and safety.
2. Rated Values: For a detailed exploration of rated values, please consult Table 2. This comprehensive resource provides all specifications necessary to make informed decisions regarding our circuit breakers, empowering you with critical insights.
3. Ambient Temperature: At a standard ambient temperature of +40ºC, delve into the intricate over-current release action characteristics found in Table 3 for distribution circuit breakers and Table 4 for motor protection circuit breakers, ensuring superior performance across varying conditions.

Rated Value: Explore the in-depth specifics of our circuit breaker's rated value, offering a clear understanding of its full capabilities to ensure it aligns perfectly with your application needs.

Model Pole Rated current (A) Rated
operating
voltage (V)
Rated
insulation
voltage (V)
Rated ultimate short - circuit breaking capacity (Icu) Flashover
distance(mm)
Test voltage (V) Icu (kA) Ics (kA)
DAM2L-63 3 10,16,20,25,
32,40,50,63
400 500 400×1.10 25 18 0
DAM2M-63 3,4 50 35
DAM2L-100 3,4 16,20,25,32,40,
50,63,80,100
400 800 30 22 ≤50
DAM2M-100 2,3,4 50 35
DAM2H-100 3 85 50
DAM2L-100 3,4 690 10 5
DAM2M-100 2,3,4 20 10
DAM2L-225 3,4 100,125,140,
160,180,200,225
400 800 35 25
TXCM1-225 2,3,4 50 35
DAM2H-225 3 85 50
DAM2L-225 3,4 690 10 5
DAM2M-225 2,3,4 20 10
DAM2L-400 3 225,250,315,
350,400
400 800 50 35 ≤100
DAM2M-400 3,4 65 42
DAM2H-400 3 100 65
DAM2L-400 3 690 15 8
DAM2M-400 3,4 20 10
DAM2L-630 3 400,500,630 400 800 50 35
DAM2M-630 3,4 65 42
DAM2H-630 3 100 65
DAM2L-630 3 6910 15 8
DAM2M-630 3,4 20 10
DAM2M-800 3 630,700,800 400 800 75 50
DAM2H-800 3 100 65
DAM2M-800 3 4690 30 15
DAM2-1250 3 800,1000,1250 400 800 85 42
DAM2-1250 3 690 25 12.5

Note: Our 2-pole and 4-pole circuit breakers, segmented into L, M, and H types, maintain a consistent breaking index aligned with the M-type, ensuring reliability and uniform performance across all models.

Inverse Time Breaking Action: Gain insight into the detailed characteristics of over-current release for power distribution, especially when all poles are energized simultaneously, delivering comprehensive and reliable protection.

No. Test current I/In Set time Initial state
1 Conventional non-tripping current 1.05 2h(In>63A),1h(In≤63A) Cold
2 Conventional non-tripping current 1.30 2h(In>63A),1h(In≤63A) Immediately after Test 1

Instantaneous Action Characteristics: Our distribution circuit breakers are meticulously engineered with a setting value of 10In±20%, while motor protection circuit breakers are stringently set at 12In±20%, ensuring effective and secure operation.

Inverse Time Breaking Action: Examine the specific characteristics of over-current release for motor protection when all poles are equally energized, ensuring dedicated and precise protection for your systems.

No. I/In Set time Initial state Remark
1 1.0 >2h Cold  
2 1.2 ≤2h Immediately after Test 1  
3 1.5 ≤4min Cold 10≤n≤225
≤8min 225 < in ≤ 630
4 7.2 4s≤T≤10s Cold 10≤In≤225
6s≤T≤20s 225 < in ≤ 630

Accessories

1. Internal Accessories of Circuit Breakers

1.1 Shunt Release
Shunt Release Voltage: Designed for utmost reliability, our shunt release operates seamlessly under a rated control supply voltage of AC50Hz, 230V, 400V, and DC110V, 220V, 24V. It assures dependable performance within a 70%~110% voltage range, ensuring flawless circuit breaker functionality.

DC24V Shunt Release: For assured reliable operation, adhere to specified standards for the maximum length of copper wire. This adherence guarantees that your circuit breaker remains operational and secure, safeguarding your electrical systems.

Rated control
supply voltage Uc(DC24V)/Conductor area
1.5mm² 2.5mm²
100%Uc
85%Uc
150m
100m
250m
160m

Design Recommendations: In instances where the specified table requirements are not met, you have the opportunity to design your shunt release control circuit by meticulously following the provided figure. This will ensure optimal functionality and uncompromised safety, reinforcing your system's reliability.

1.2 Under-Voltage Release

Under-Voltage Operation: Our under-voltage release is engineered to ensure dependable circuit breaker performance even when the supply voltage significantly decreases to levels between 70%-35% of the rated voltage. This feature is paramount for maintaining the highest standards of safety and operational functionality.
Under-Voltage Protection: Our innovative under-voltage release prevents the circuit breaker from engaging when the voltage dips below 35% of the rated value, safeguarding your equipment. Conversely, when the voltage surpasses 85%, the system ensures secure closure, offering you both safety assurance and operational reliability.
Closing Mechanism: To guarantee secure circuit breaker operation, our under-voltage release actively facilitates closure when supply voltages are above 85% of the rated value. This mechanism is designed to enhance your system's safety and optimize operational integrity.
Under-Voltage Ratings: For unwavering performance, our devices are calibrated to AC50Hz, 230V, 400V, ensuring that they consistently meet the highest standards of reliability and safety for your peace of mind.
400V.
Special Note: Circuit breakers equipped with our under-voltage releases are meticulously designed to function optimally at the designated rated voltage, securing safe and efficient opening and closing cycles for enhanced operational safety.
normally.

1.3 Pre-Paid Meter Dedicated Release

Our cutting-edge pre-paid meter dedicated release is a marvel of modern engineering, designed with a rated operating voltage Ue of AC230/50Hz. It delivers exceptional performance across a flexible range of 65% to 110% of Ue. Ingeniously, when the control (Ctrl) is disengaged, the circuit breaker activates a delayed opening mechanism, ranging from 0.5 to 2 seconds, ensuring maximum safety and unrivaled reliability, offering you the ultimate peace of mind.

Wiring Diagram for Pre-Paid Meter Dedicated Release: Your comprehensive guide to achieving seamless connectivity and optimal performance.

1.4 Rated Values of Auxiliary Contacts and Alarm Contacts (Refer to Table 5 for comprehensive details)

Classification Conventional thermal current (Ith) Rated current when

 

AC 400V Ie(AC-15)

Rated current when

 

DC 220V Ie(DC-13)

Auxiliary contact 3 0.4 0.15
Alarm contact 3 0.3 0.15

a. Auxiliary Contact: Essential for bolstering operational efficiency and ensuring seamless system integration.

b. Alarm Contact: Precisely engineered for delivering reliable and timely notifications, enhancing your system's safety.
Our sophisticated alarm contacts are expertly designed to remain inert during normal operations, only switching between normal open and closed states upon free or fault tripping. This ensures that precise alerts are triggered exclusively when truly necessary, optimizing safety and reliability.

2. External Accessories for Circuit Breakers: Elevate your circuit breaker functionality and performance with our high-quality accessories.

2.1 Motor Operating Mechanism: Delve into the rated values and their corresponding codes as detailed in Table 6 for a comprehensive understanding and informed decision-making.

Category/Model DAM2-63. 125. 250 DAM2-400. 630. 800. 1250
Structure type Electromagnet Motor
AC voltage code AC50Hz,230V,400 AC50Hz,230V,400
DC voltage code DC110V,220V DC110V,220V

NOTE: Following a circuit breaker trip with an electric operating mechanism, it is imperative that a reset is performed before re-engagement. This ensures the system's operational readiness and reliability.

Principle Diagram for the Opening and Closing of DAM2-63,100,225 Electric Operating Mechanism (AC): Visualize the intricate process to gain a comprehensive understanding for optimal system utilization.

Principle Diagram for Opening and Closing of DAM2-400,630,800,1250 Electric Operating Mechanism (AC): Gain a clear perspective on high-capacity operations with this detailed visualization.

2.2 Installation Dimensions for Manual Operating Mechanism: Refer to Table 10 to ensure a precise fit and flawless function in your installations, guaranteeing optimal performance.
Diagram of Handle Mounting Hole for DAM2-63~800: Your go-to guide for achieving precise installation and ensuring system integrity.

Total Height of Electric/Manual Operating Mechanism of Circuit Breaker (mm) (Refer to Table 12): Verify accurate integration with your systems to enhance efficiency and reliability.

Model Total height of electric
operating mechanism H
Installation dimensions

 

of manual operating mechanism H

DAM2L-63 155 49
DAM2M/H-63 164 49
DAM2L-100 152 51
DAM2M/H-100 170 51
DAM2L-225 182 54
DAM2M/H-225 199 54
DAM2L/M/H-400 255 88
DAM2M/H-630 262 89
DAM2M/H-800 261 96
DAM2H-1250 290 103

Quick Selection Table for DAM2 Series Molded Case Circuit Breakers: Your simplified guide to selecting the perfect circuit breaker with ease and precision.

Corresponding
letters
Function name Function corresponding to the model
a Model features DAM2 Molded Case

 

Circuit Breaker

b Frame rated current code 63A,100A,225A,

 

400A,630A,800A,

1250A

c Breaking capacity characteristic
code
L-standard breaking type;

 

M-second high breaking type;

H-high breaking type

d Operation mode code No code for handle operation;

 

P for electric operation;

Z for turning handle operation

e Pole 2-two poles;

 

3-three poles;

4-four poles

f Release name 2 Electromagnetic release;

 

3 Double release

g Accessory 00 Without accessory
08 Alarm contact
10 Shunt release
20 Auxiliary contact
30 Undervoltage release
40 Shunt release, Auxiliary contact
50 Shunt release, Undervoltage release
60 Two sets of auxiliary contacts
70 Auxiliary contact, Undervoltage release
18 Shunt release, Alarm contact
28 Auxiliary contact, Alarm contact
38 Undervoltage release, Alarm contact
48 Shunt release, Auxiliary contact, Alarm contact
58 Shunt release, Undervoltage release, Alarm contact
68 Two sets of auxiliary contacts, Alarm contact
78 Auxiliary contact, Undervoltage release, Alarm contact
10Y Pre-paid meter dedicated release
40Y Pre-paid meter dedicated release, Auxiliary contact
50Y Pre-paid meter dedicated release, Auxiliary contact, Undervoltage release
18Y Pre-paid meter dedicated release, Alarm contact
48Y Pre-paid meter dedicated release, Auxiliary contact, Alarm contact
58Y Pre-paid meter dedicated release, Undervoltage release, Alarm contact
h Application No code for distribution;

 

2 for motor protection

i Conventional products No code;

 

T for transparent cover products

j Amperage 10,16,20,25,32,63,80,100,125,160,180,200
,225,250,315,350,400,500,630,700,800,1000
,1250

Example: DAM2L-100 / 33102 63A stands for a DAM2-type molded case circuit breaker with a frame rated current of 100A. It offers standard breaking capacity, handle operation, 3 poles, double release, and shunt release, expertly engineered for motor protection with a rated current of 63A, ensuring superior performance.
To unlock the paramount efficiency of the Cdada 250A Moulded Case Switch for Fixed Type Circuit Breaker, it is imperative that all selection, installation, and usage are in complete conformity with the comprehensive product manual or adhere to the established relevant national standards. This ensures the longevity and optimal performance of your equipment.
Important Note: When considering the N-pole type of a 4P circuit breaker, it is critical to recognize the distinction between A-type and B-type classifications. In the absence of a specific request, B-type is designated as the default choice, providing a standard solution for most applications.

Working Principle: Immerse yourself in the intricate details of the core mechanism operation, which highlights the engineering excellence behind our cutting-edge technology.
The main contact of the molded case circuit breaker is designed for seamless operation, allowing it to be closed either manually or electrically with ease. Once closure is achieved, the advanced free release mechanism ensures unwavering security, locking the main contact firmly in the closed position to maintain a stable and safe operational environment.
The overcurrent trip coil and the thermal trip element are exquisitely engineered to be intricately connected in series with the main circuit. This sophisticated design ensures responsive and precise protection, safeguarding your equipment against potential overcurrent events.
Voltage
release: This is a pivotal safety feature that guarantees reliable and safe operation, providing peace of mind during usage.
The coil and the power supply are strategically connected in parallel, assuring you of a robust and dependable performance that meets the rigorous demands of your operational needs.
Cdada 250A Moulded Case Switch for Fixed Type Circuit Breaker

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier