Compared to the DAM1 series, the DAM3 series stands out with a more compact design, superior breaking capacity, and enhanced energy efficiency. This series represents a leap forward in both performance and sustainability.
Electrical Parameters of DAM3-250 Molded Case Circuit BreakerRated current of frame size Inm [A] | 250 | ||||
Rated current [A] | 100-250 | 100-225 | |||
Number of poles | 2 / 3 / 4 | ||||
Rated operating voltage | (AC)50-60HZ [V] | 400/690 | |||
DC [V] | 250/1000 | ||||
Rated impulse withstand voltage Uimp [KV] | 8 | ||||
Rated insulation voltage Ui [V] | 750 | ||||
Test voltage at industrial frequency for 1 min [V] | 3000 | ||||
Rated ultimate short-circuit breaking capacity Icu [KA] | B | C | N | S | |
(AC)50-60HZ 220/230V [KA] | 30 | 36 | 50 | 75 | |
(AC)50-60HZ 400/415V [KA] | 18 | 25 | 36 | 50 | |
(AC)50-60HZ 690V [KA] | 6 | 8 | 12 | 15 | |
(DC)250V-2 Poles in series | 18 | 22 | 30 | 40 | |
(DC)500V-2 Poles in series | 9 | 12 | 15 | 20 | |
(DC)750V-4 Poles in series | 16 | 18 | 22 | 30 | |
(DC)1000V-4 Poles in series | 13 | 15 | 18 | 25 | |
Rated service short-circuit breaking capacity, Ics [KA] | |||||
(AC)50-60HZ 220/230V [%Icu] | 60% | 60% | 60% | 50% | |
(AC)50-60HZ 400/415V [%Icu] | 60% | 60% | 60% | 50% | |
(AC)50-60HZ 690V [%Icu] | 60% | 60% | 60% | 50% | |
category of utilization (EN 60947-2) | A | ||||
Isolation condition | Bitmap | ||||
Reference standard | IEC/EN 60947-2/GB 14048.2 | ||||
Interchangeability | Bitmap | ||||
Versions | Fixed | Bitmap | |||
Plug-in | Bitmap | ||||
Draw-out | - |
Endurance | Total cycles | 10000 | |
Electrical endurance | 1500 | ||
Mechanical endurance | 8500 | ||
Basic dimensions-fixed version |
3/4 Poies W[mm] | 70(2P) /104 /139 | |
3/4 Poies H[mm] | 59 | 62.5 | |
H1[mm] | 78.5 | 82 | |
3/4 Poies L[mm] | 139 |
Introduction
The DAM3-250 molded case circuit breaker is engineered to automatically disconnect the current flow when it exceeds the pre-set threshold. The term 'molded case' refers to the durable plastic insulator that forms the frame of the device, effectively insulating the conductor and the metallic grounding components.
Working Principle
The main contact of the DAM3-250 molded case circuit breaker can be operated manually or closed electrically. Once the main contact is secured, the free release mechanism locks it into the closed position. The overcurrent trip coil and thermal trip element are in series with the main circuit, while the undervoltage trip coil is connected in parallel with the power supply to ensure optimal performance and safety under varying electrical conditions.