MCCB 3p 250A Distribution Breaker with 1000V Rated Insulation Voltage

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 26/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • MCCB 3p 250A Distribution Breaker with 1000V Rated Insulation Voltage
  • MCCB 3p 250A Distribution Breaker with 1000V Rated Insulation Voltage
  • MCCB 3p 250A Distribution Breaker with 1000V Rated Insulation Voltage
  • MCCB 3p 250A Distribution Breaker with 1000V Rated Insulation Voltage
  • MCCB 3p 250A Distribution Breaker with 1000V Rated Insulation Voltage
  • MCCB 3p 250A Distribution Breaker with 1000V Rated Insulation Voltage
Find Similar Products

Basic Info.

Model NO.
DAM1-250
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
ISO9001-2000, CE, CB, CCC, Asta, Semko, RoHS
Base
BMC Unflaming Material
Rated Insulation Voltage
1000V
Rated Operation Voltage
400/415V
Outline Dimension
170X105X103.5mm
Transport Package
Carton
Specification
63, 80, 100, 125, 160, 200, 250, 315A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
8536200000
Production Capacity
20000PCS/Month

Product Description

Introduction

The DAM1 series circuit breakers are meticulously designed to ensure seamless current conduction during standard operations, while providing robust protection by swiftly switching off during short circuits, overloads, and inadmissible voltage drops. These breakers are ideal for electric installations with an operational voltage up to 400V and a rated current ranging from 12.5A to 1600A.

They adhere to the stringent standards set by EN 60947-1 and EN 60947-2.

Thermal-Magnetic Circuit Breakers:

Thermal Protection Function: (Protection against overload conditions)
The bimetal strip, the heart of thermal protection, consists of two metals with distinct expansion rates when heated. As the bimetal warms, it bends towards the metal with the lower expansion rate, triggering a notch that facilitates the breaker's mechanism to open and interrupt the current. The bending speed of the bimetal is directly proportional to the current passing through, as more current generates more heat. Thus, the thermal protection function activates to safeguard against overcurrent conditions by utilizing the bimetal strip when load currents exceed the rated limits.
Magnetic Protection Function:(Protection under short circuit conditions) Another critical function of the breaker is toshield the connected circuit against shortcircuits. Short circuits may arise due tothe contact between phases orphase-ground contact. Given the veryhigh current that flows during a short circuit, the system's energyneeds to be interrupted quickly, surpassingthermal protection capabilities. The breaker mustperform an instantaneous disconnection to protect the connected load.This crucial function is executed by a mechanicalrelease mechanism thatactivates throughmagnetization generated by the magnetic field created by the short circuit current.
Thermal-Magnetic fixed type Circuit Breakers  
Model DAM1-250
Breaking Capacity Code N S H G
Rated Current of Frame size- Inm                                                                    (A) 250A
Rated Current-In(40,50 or 55ºC)                                                                      (A) 63 - 80-100-125 - 160(180) -  200(225) - 250(320)A
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz                                                    (V) 750V
Rated operation Voltage  -Ue(a.c.) 50-60Hz                                                    (V) 400/415V
Number of Pole 3P /4P
Rated ultimate short Circuit breaking Capacity  kA  Icu AC400V/50Hz O-CO          (KA) 35 50 65 85
Rated service short Circuit breaking Capacity  kA  Ics AC400V/50Hz O-CO-CO     (KA) 26.25 37.5 48.75 51
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO         (KA) 77/0.25 114/0.25 143/0.2 178/0.2
Rated impulse withstand Voltage -Uimp                                                                            (V) 8000
Dielectric Propery (V) 3000
lonization distance                                                                                                              (mm) 30/0
Endurance Total Cycles 8000
Electrical Life 1000
Mechanical Life 7000
Over Current trip Thermal and Magnetic release fix type
Category (EN 60947-2/IEC 60947-2) Main circuit A/B
Auxiliary circuit AC-15
Under Voltage Release 
Shunt Release
Auxiliary Contact
Alarm Contact
Auxiliary Contact and Alarm Contact
Handle Operation Mechanism
Electrical Operastion Mechanism 
DIN clips -
Terminal cover    
Phase seperator    
Extention Handle     -
  W (mm) 3P 105
4P 140
L (mm) 3P 170
4P 170
H (mm) 3P 103.5
4P 103.5
Weight Fixed version 3P/4P 2.7/3.5 41.5/5.5
Plug-in version 3P/4P 3.2/4.2 4.6/6
Draw out version 3P/4P 3.6/4.6 5/6.4

MCCB 3p 250A Distribution Breaker with 1000V Rated Insulation VoltageMCCB 3p 250A Distribution Breaker with 1000V Rated Insulation VoltageMCCB 3p 250A Distribution Breaker with 1000V Rated Insulation VoltageMCCB 3p 250A Distribution Breaker with 1000V Rated Insulation VoltageMCCB 3p 250A Distribution Breaker with 1000V Rated Insulation VoltageMCCB 3p 250A Distribution Breaker with 1000V Rated Insulation VoltageMCCB 3p 250A Distribution Breaker with 1000V Rated Insulation VoltageMCCB 3p 250A Distribution Breaker with 1000V Rated Insulation VoltageMCCB 3p 250A Distribution Breaker with 1000V Rated Insulation VoltageMCCB 3p 250A Distribution Breaker with 1000V Rated Insulation VoltageMCCB 3p 250A Distribution Breaker with 1000V Rated Insulation VoltageMCCB 3p 250A Distribution Breaker with 1000V Rated Insulation Voltage