The Dada DAM3-1600 molded case circuit breaker is engineered to handle a formidable rated current of up to 1600A. Crafted for the safeguarding of power distribution circuits operating with an alternating current of 50-60Hz, it reliably functions at a rated operating current of up to 1000A. This versatile device is also adept at managing electric motors, providing not only infrequent starting capabilities but also robust protection against overloads, short circuits, and undervoltage incidents.
In comparison to the DAM1 series, the innovative DAM3 series is a marvel of engineering with its compact footprint, superior breaking capacity, and enhanced energy efficiency, making it a leading choice for modern applications.
Electrical parameters of DAM3-1600 molded case circuit breakerRated current of frame size Inm [A] | 1600 | |||
Rated current [A] | 1000 1250 1600 | |||
Number of poles | 3 / 4 | |||
Rated operating voltage | (AC)50-60HZ [V] | 400/690 | ||
DC [V] | 250/1000 | |||
Rated impulse withstand voltage Uimp [KV] | 8 | |||
Rated insulation voltage Ui[V] | 750 | |||
Test voltage at industrial frequency for 1 min [V] | 3000 | |||
Rated ultimate short-circuit breaking capacity Icu [KA] | S | H | G | |
(AC)50-60HZ 220/230V [KA] | 80 | 105 | 130 | |
(AC)50-60HZ 400/415V [KA] | 55 | 70 | 100 | |
(AC)50-60HZ 690V[KA] | 20 | 25 | 30 | |
(DC)250V-2 Poles in series | 50 | 65 | 80 | |
(DC)500V-2 Poles in series | 22 | 30 | 40 | |
(DC)750V-4 Poles in series | 42 | 55 | 68 | |
(DC)1000V-4 Poles in series | 35 | 45 | 55 | |
Rated service short-circuit breaking capacity, Ics [KA] | ||||
(AC)50-60HZ 220/230V [%Icu] | 60% | 60% | 60% | |
(AC)50-60HZ 400/415V [%Icu] | 60% | 60% | 60% | |
(AC)50-60HZ 690V[%Icu] | 60% | 60% | 60% | |
Category of utilisation(EN 60947-2) | A | |||
Isolation condition | Bitmap | |||
Reference standard | IEC/EN 60947-2/GB 14048.2 | |||
Interchangeability | Bitmap | |||
Versions | Fixed | Bitmap | ||
Plug-in | Bitmap | |||
Draw-out | Bitmap |
Endurance | Total cycles | 5000 |
Electrical endurance | 1000 | |
Mechanical endurance | 4000 | |
Basic dimensjons-fixed version |
3/4 Poies W[mm] | 210/280 |
3/4 Poies H[mm] | 140 | |
H1[mm] | 196 | |
3/4 Poies L[mm] | 328 |
Introduction
The DAM3-1600 molded case circuit breaker is designed to take action with precision, automatically severing the current flow upon surpassing the release settings. Its molded case, constructed from durable plastic insulators, serves as a resilient framework that effectively insulates the conductor while securing the metal grounding components.
Working principle
The operation of the DAM3-1600 molded case circuit breaker is a blend of manual dexterity or electrical automation, closing the main contact with ease. Once closed, the free release mechanism steadfastly secures the main contact in a closed position. An overcurrent trip coil, paired with a thermal trip element, forms a series with the main circuit, while the undervoltage trip coil works in harmony, connected parallelly with the power supply to ensure seamless protection.