High-Quality ELCB MCCB 4p 125 Circuit Breaker Earth Leakage Protection

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 45/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • High-Quality ELCB MCCB 4p 125 Circuit Breaker Earth Leakage Protection
  • High-Quality ELCB MCCB 4p 125 Circuit Breaker Earth Leakage Protection
  • High-Quality ELCB MCCB 4p 125 Circuit Breaker Earth Leakage Protection
  • High-Quality ELCB MCCB 4p 125 Circuit Breaker Earth Leakage Protection
  • High-Quality ELCB MCCB 4p 125 Circuit Breaker Earth Leakage Protection
  • High-Quality ELCB MCCB 4p 125 Circuit Breaker Earth Leakage Protection
Find Similar Products

Basic Info.

Model NO.
DAM1L-125
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
4
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CB, CCC
Cover
BMC Material
Base
BMC Material
Netural Pole
Left Side
Transport Package
Carton
Specification
16, 20, 25, 32, 40, 50, 63, 80, 100, 125A
Trademark
CDADA, OEM, ODM
Origin
Shanghai
HS Code
85362000
Production Capacity
8000PCS/Month

Product Description

DAM1L-125 series Earth Leakage protection circuit breaker(ELCB)

4
P 400V/415V
Earth leakage
circuit breaker high quality
with CE,CB,SEMKO certificate
High-Quality ELCB MCCB 4p 125 Circuit Breaker Earth Leakage Protection
Introduction
DAM1L
series residual current (leakage) circuit breaker (hereinafter referred to as circuit breaker) is a new series of residual current (leakage) successfully developed by using international standard design and advanced manufacturing technology.

Protected
moulded case
type circuit breaker.
The rated insulation voltage of circuit breakers of this series is 400V (Inm is less than 160A) and 690V (Inm is more than 250A), which is mainly used for ac 50Hz and rated
In a power distribution network with a current of 10A~
5
00A and a rated working voltage of 380V/400V, it is used to distribute electric energy and protect the overload and short circuit of lines and power equipment.
Under normal conditions
,
It can also be used for infrequent switching of lines.
T
his circuit breaker also has the following protection:
·It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection.
·Provide protection against the danger of increasing ground voltage due to insulation damage;
·Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection.
·Circuit breakers with rated current of
5
00A and below can also be used for infrequent start, break off during operation and overload and short circuit protection of squirrel cage motors.
DAM1L
series circuit breakers can be equipped with electric accessories and mechanical accessories for various purposes, such as separately excited tripping device, auxiliary contact, alarm contact and rotating handle operating mechanism.

This series of circuit breakers are widely used in construction, transportation, tunnel, residence, etc.The delay type in this series of circuit breakers is used for branch lines
Distribution of roads;Adjustable type is used to adjust the residual action current or disconnection time on site.

Advantages

°
R
ange:10A to
5
00A(AC)
°integral structure, small volume, high breaking capacity, safe and reliable.
°Adjustable magnetic setting(
0.8
-1times)In.
°Push to trip button provision.
°Dedicated main and arcing contacts for enhanced performance and safety.
°
C
ustomizable residual action current and disconnection time to match specific usage needs.
°
S
uperior anti-interference capability ensuring reliable operation.
°Comprehensive range of accessories to meet diverse installation requirements.

This series of circuit breakers' residual current protection circuits are powered by a multi-phase power supply, offering enhanced reliability compared to early models that used single-phase power supplies.
T
he device's residual current protection circuit continues to operate effectively even when the operating power voltage drops to 50V, maintaining functionality at a residual current of 30mA.

This series of circuit breakers is classified into B type (basic breaking capacity, Inm < 100), S type (standard breaking capacity), and H type (high breaking capacity, Inm > 160), providing solutions for various application scenarios.
Designed to handle high breaking capacities (Inm > 160), these circuit breakers are versatile for different situations.

The main circuit of a circuit breaker can be connected in multiple ways:
-
Front piston connection
-
Front connection with terminal extension plate
-
Rear screw connection at the piston plate
High-Quality ELCB MCCB 4p 125 Circuit Breaker Earth Leakage ProtectionHigh-Quality ELCB MCCB 4p 125 Circuit Breaker Earth Leakage ProtectionHigh-Quality ELCB MCCB 4p 125 Circuit Breaker Earth Leakage ProtectionHigh-Quality ELCB MCCB 4p 125 Circuit Breaker Earth Leakage Protection

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier