Cdada Dam2 250A Moulded Case Circuit Breaker Fixed Type MCCB

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 10/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Cdada Dam2 250A Moulded Case Circuit Breaker Fixed Type MCCB
  • Cdada Dam2 250A Moulded Case Circuit Breaker Fixed Type MCCB
  • Cdada Dam2 250A Moulded Case Circuit Breaker Fixed Type MCCB
  • Cdada Dam2 250A Moulded Case Circuit Breaker Fixed Type MCCB
  • Cdada Dam2 250A Moulded Case Circuit Breaker Fixed Type MCCB
  • Cdada Dam2 250A Moulded Case Circuit Breaker Fixed Type MCCB
Find Similar Products

Basic Info.

Model NO.
CM1-125
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Transport Package
Carton
Specification
12.5, 16, 20, 25, 32, 40, 50, 70, 80, 100A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
85362000
Production Capacity
10000PCS/Month

Product Description

Cdada Dam2 250A Moulded Case Circuit Breaker Fixed Type MCCB


Introducing the revolutionary DAM2 series Moulded Case Circuit Breaker, a marvel of modern engineering crafted with the latest international technology. Engineered for excellence, these circuit breakers feature a compact design, superior breaking capacity, minimal arc-over distance, and a robust shake-proof structure. They are the ultimate choice for dependable performance in both terrestrial and maritime environments.

Application

The DAM2 (CM1) series circuit breaker is a powerhouse, designed with a rated insulation voltage of 800V. Perfectly suited for AC distribution networks of 50Hz/60Hz, it handles a rated working voltage of up to 690V and a current of up to 1250A. It excels in distributing power while safeguarding circuits and equipment from overloads, short-circuits, under-voltage, and other potential faults. Additionally, it supports infrequent circuit conversions and motor starts, offering versatility in installation - whether vertical or horizontal. Suitable for isolation, denoted by the symbol ' ', the DAM2 MCCB complies with the high standards of IEC60947-2 for low-voltage switchgear and control equipment, Part 2: circuit breakers.

Cdada Dam2 250A Moulded Case Circuit Breaker Fixed Type MCCBCdada Dam2 250A Moulded Case Circuit Breaker Fixed Type MCCB

Normal operating conditions

1. Ambient air temperature: Maintain between -5ºC to +40ºC, ensuring an average daily temperature does not exceed +35ºC.
2. Altitude: Ensure that the installation site does not surpass an altitude of 2000 meters.
3. Atmospheric conditions: At a peak temperature of +40ºC, the relative humidity should not exceed 50%. Higher humidity levels are acceptable at reduced temperatures, with a maximum average relative humidity of 90% and a minimum average monthly temperature of +25ºC, considering temperature-induced condensation on the product's surface.
4. Pollution Degree: Level 3.

Selection of instructions

Classified by pole types:
Type A: N-pole without over-current release components, continuously connected, and does not operate with the other three poles.
Type B: N-pole without over-current release components, operates alongside the other three poles (N-pole activates before deactivation).
Type C: N-pole with over-current release components, operates with the other three poles (N-pole activates prior to deactivation).

Classified by rated current of over-current release:
DAM2-63 MCCB Available in nine ratings: 6, 10, 16, 20, 25, 32, 40, 50, 63 A, catering to diverse requirements.
DAM2-100 MCCB Available in nine ratings: 16, 20, 25, 32, 40, 50, 63, 80, 100 A, offering versatility in application.
DAM2-250 MCCB Available in seven ratings: 100, 125, 140, 160, 180, 200, 225, 250 A, ensuring flexibility for different needs.
DAM2-400 MCCB Available in five ratings: 225, 250, 315, 350, 400 A, designed for high-performance standards.
DAM2-630 MCCB Available in three ratings: 400, 500, 630 A, for those powerful, demanding applications.
DAM2-800 MCCB Available in three ratings: 630, 700, 800 A, tailored for higher capacity needs.
DAM2-1250 MCCB available in three ratings: 800, 1000, 1250 A, for ultimate power and protection.
Remark: Please note that the 6A version is confined to electromagnetic (instantaneous) type operation and is not recommended due to its specification constraints. Choose with discretion for optimal performance.
Wiring Options: Tailor your installation with our array of wiring choices-front-of-board, back-of-board, or insertion type. These versatile options ensure seamless integration into a variety of setups.
Over-Current Release Patterns: Our circuit breakers are available in both thermodynamic-electromagnetic (dual) type and electromagnetic (instantaneous) type, designed to meet a wide range of application requirements with precision and reliability.
Outfit Options: Customize your circuit breaker to align with your specific requirements by selecting either with or without outfit options, ensuring the best fit for your electrical systems.
Outfit Details: Enhance your circuit breaker's functionality with our inner accessories, like the shunt release, under-voltage release, auxiliary contact, and alarm contact. For outer accessories, choose from turning handle operation mechanisms and power-driven operation mechanisms, providing comprehensive control solutions.
Breaking Capacity: Select from our diverse capacity options-L-standard breaking, M-second high breaking, and H-high breaking types-to perfectly match the diverse demands of your applications and ensure optimal circuit protection.

Cdada Dam2 250A Moulded Case Circuit Breaker Fixed Type MCCBCdada Dam2 250A Moulded Case Circuit Breaker Fixed Type MCCB


Technical Parameters

1. Instantaneous Action Characteristics: Our distribution circuit breakers boast a setting value of 10In±20%, while the DAM2-1250 model is precisely configured at 7In±20%. Motor protection circuit breakers are rigorously set to 12In±20% to ensure peak performance and safety.
2. Rated Values: For a comprehensive understanding of the rated values, please refer to Table 2, where detailed specifications are provided for our circuit breakers, ensuring you have all the information required for informed decision-making.
3. Ambient Temperature: At an ambient temperature of +40ºC, explore the detailed over-current release action characteristics in Table 3 for distribution circuit breakers and Table 4 for motor protection circuit breakers, ensuring robust performance across varying conditions.

Rated Value: Dive into the detailed specifics of our circuit breaker's rated value, providing a clear understanding of its capabilities and ensuring it meets your application needs.

Model Pole Rated current (A) Rated
operating
voltage (V)
Rated
insulation
voltage (V)
Rated ultimate short - circuit breaking capacity (Icu) Flashover
distance(mm)
Test voltage (V) Icu (kA) Ics (kA)
DAM2L-63 3 10,16,20,25,
32,40,50,63
400 500 400×1.10 25 18 0
DAM2M-63 3,4 50 35
DAM2L-100 3,4 16,20,25,32,40,
50,63,80,100
400 800 30 22 ≤50
DAM2M-100 2,3,4 50 35
DAM2H-100 3 85 50
DAM2L-100 3,4 690 10 5
DAM2M-100 2,3,4 20 10
DAM2L-225 3,4 100,125,140,
160,180,200,225
400 800 35 25
TXCM1-225 2,3,4 50 35
DAM2H-225 3 85 50
DAM2L-225 3,4 690 10 5
DAM2M-225 2,3,4 20 10
DAM2L-400 3 225,250,315,
350,400
400 800 50 35 ≤100
DAM2M-400 3,4 65 42
DAM2H-400 3 100 65
DAM2L-400 3 690 15 8
DAM2M-400 3,4 20 10
DAM2L-630 3 400,500,630 400 800 50 35
DAM2M-630 3,4 65 42
DAM2H-630 3 100 65
DAM2L-630 3 6910 15 8
DAM2M-630 3,4 20 10
DAM2M-800 3 630,700,800 400 800 75 50
DAM2H-800 3 100 65
DAM2M-800 3 4690 30 15
DAM2-1250 3 800,1000,1250 400 800 85 42
DAM2-1250 3 690 25 12.5

Note: For our 2-pole and 4-pole circuit breakers, categorized into L, M, and H types, rest assured that the breaking index for all aligns with the M-type, providing consistency and reliability across models.

Inverse Time Breaking Action: Understand the nuanced characteristics of over-current release for power distribution, particularly when all poles are energized simultaneously, ensuring comprehensive protection.

No. Test current I/In Set time Initial state
1 Conventional non-tripping current 1.05 2h(In>63A),1h(In≤63A) Cold
2 Conventional non-tripping current 1.30 2h(In>63A),1h(In≤63A) Immediately after Test 1

Instantaneous Action Characteristics: Our distribution circuit breakers are engineered with a setting value of 10In±20%, while motor protection circuit breakers are rigorously set at 12In±20%, ensuring effective and safe operation.

Inverse Time Breaking Action: Delve into the characteristics of over-current release for motor protection when all poles are equally energized, ensuring tailored protection for your systems.

No. I/In Set time Initial state Remark
1 1.0 >2h Cold  
2 1.2 ≤2h Immediately after Test 1  
3 1.5 ≤4min Cold 10≤n≤225
≤8min 225 < in ≤ 630
4 7.2 4s≤T≤10s Cold 10≤In≤225
6s≤T≤20s 225 < in ≤ 630

Accessories

1. Internal Accessories of Circuit Breakers

1.1 Shunt Release
Shunt Release Voltage: Engineered for reliability, our shunt release operates under a rated control supply voltage of AC50Hz, 230V, 400V, and DC110V, 220V, 24V. It guarantees dependable performance within a 70%~110% voltage range, ensuring your circuit breaker functions flawlessly.

DC24V Shunt Release: To ensure reliable operation, the maximum length of copper wire should adhere to specified standards. This guarantees that your circuit breaker remains operational and secure.

Rated control
supply voltage Uc(DC24V)/Conductor area
1.5mm² 2.5mm²
100%Uc
85%Uc
150m
100m
250m
160m

Design Recommendations: Should the specified table requirements not be met, design your shunt release control circuit following the provided figure, ensuring optimal functionality and safety.

1.2 Under-Voltage Release

Under-Voltage Operation: Our under-voltage release guarantees reliable circuit breaker operation when the supply voltage drops to 70%-35% of the rated voltage, maintaining safety and functionality.
Under-Voltage Protection: If the voltage falls below 35% of the rated value, the under-voltage release prevents the circuit breaker from closing. When above 85%, it ensures closure, offering both safety and operational reliability.
Closing Mechanism: To ensure secure circuit breaker operation, the under-voltage release facilitates closure at supply voltages above 85% of the rated value, optimizing system safety.
Under-Voltage Ratings: For consistent performance, our devices are rated at AC50Hz, 230V, 400V, ensuring they meet the highest standards of reliability and safety.
400V.
Special Note: Circuit breakers equipped with under-voltage releases are designed to function optimally at the rated voltage, securing safe opening and closing cycles.
normally.

1.3 Pre-Paid Meter Dedicated Release

Our state-of-the-art pre-paid meter dedicated release boasts a rated operating voltage Ue of AC230/50Hz, delivering unparalleled performance within a versatile range of 65% to 110% of Ue. In a remarkable feat of engineering, when control (Ctrl) is disengaged, the circuit breaker innovatively initiates a delayed opening, spanning from 0.5 to 2 seconds. This ensures maximum safety and reliability, providing you with peace of mind.

Wiring Diagram for Pre-Paid Meter Dedicated Release: Your guide to seamless connectivity.

1.4 Rated Values of Auxiliary Contacts and Alarm Contacts (Refer to Table 5 for comprehensive details)

Classification Conventional thermal current (Ith) Rated current when

 

AC 400V Ie(AC-15)

Rated current when

 

DC 220V Ie(DC-13)

Auxiliary contact 3 0.4 0.15
Alarm contact 3 0.3 0.15

a. Auxiliary Contact: Essential for enhanced operational efficiency.

b. Alarm Contact: Precision-engineered for reliable notifications.
Our sophisticated alarm contacts are meticulously designed to remain dormant during normal operations, switching between normal open and closed states only during free or fault tripping. This ensures precise alerts are triggered only when truly necessary.

2. External Accessories for Circuit Breakers: Enhance functionality and performance.

2.1 Motor Operating Mechanism: Explore the rated values and their corresponding codes in Table 6 for detailed insights.

Category/Model DAM2-63. 125. 250 DAM2-400. 630. 800. 1250
Structure type Electromagnet Motor
AC voltage code AC50Hz,230V,400 AC50Hz,230V,400
DC voltage code DC110V,220V DC110V,220V

NOTE: Post-tripping of the circuit breaker with an electric operating mechanism requires a reset before re-engagement, ensuring operational readiness.

Principle Diagram for the Opening and Closing of DAM2-63,100,225 Electric Operating Mechanism (AC): Visualize the process for optimal understanding.

Principle Diagram for Opening and Closing of DAM2-400,630,800,1250 Electric Operating Mechanism (AC): A clear view of high-capacity operations.

2.2 Installation Dimensions for Manual Operating Mechanism: Refer to Table 10 to ensure precision fit and function.
Diagram of Handle Mounting Hole for DAM2-63~800: A guide to precise installation.

Total Height of Electric/Manual Operating Mechanism of Circuit Breaker (mm) (Refer to Table 12): Ensure accurate integration with your systems.

Model Total height of electric
operating mechanism H
Installation dimensions

 

of manual operating mechanism H

DAM2L-63 155 49
DAM2M/H-63 164 49
DAM2L-100 152 51
DAM2M/H-100 170 51
DAM2L-225 182 54
DAM2M/H-225 199 54
DAM2L/M/H-400 255 88
DAM2M/H-630 262 89
DAM2M/H-800 261 96
DAM2H-1250 290 103

Quick Selection Table for DAM2 Series Molded Case Circuit Breakers: Simplifying your choice for perfection.

Corresponding
letters
Function name Function corresponding to the model
a Model features DAM2 Molded Case

 

Circuit Breaker

b Frame rated current code 63A,100A,225A,

 

400A,630A,800A,

1250A

c Breaking capacity characteristic
code
L-standard breaking type;

 

M-second high breaking type;

H-high breaking type

d Operation mode code No code for handle operation;

 

P for electric operation;

Z for turning handle operation

e Pole 2-two poles;

 

3-three poles;

4-four poles

f Release name 2 Electromagnetic release;

 

3 Double release

g Accessory 00 Without accessory
08 Alarm contact
10 Shunt release
20 Auxiliary contact
30 Undervoltage release
40 Shunt release, Auxiliary contact
50 Shunt release, Undervoltage release
60 Two sets of auxiliary contacts
70 Auxiliary contact, Undervoltage release
18 Shunt release, Alarm contact
28 Auxiliary contact, Alarm contact
38 Undervoltage release, Alarm contact
48 Shunt release, Auxiliary contact, Alarm contact
58 Shunt release, Undervoltage release, Alarm contact
68 Two sets of auxiliary contacts, Alarm contact
78 Auxiliary contact, Undervoltage release, Alarm contact
10Y Pre-paid meter dedicated release
40Y Pre-paid meter dedicated release, Auxiliary contact
50Y Pre-paid meter dedicated release, Auxiliary contact, Undervoltage release
18Y Pre-paid meter dedicated release, Alarm contact
48Y Pre-paid meter dedicated release, Auxiliary contact, Alarm contact
58Y Pre-paid meter dedicated release, Undervoltage release, Alarm contact
h Application No code for distribution;

 

2 for motor protection

i Conventional products No code;

 

T for transparent cover products

j Amperage 10,16,20,25,32,63,80,100,125,160,180,200
,225,250,315,350,400,500,630,700,800,1000
,1250

Example: DAM2L-100 / 33102 63A defines a DAM2-type molded case circuit breaker with a frame rated current of 100A, offering standard breaking capacity, handle operation, 3 poles, double release, and shunt release. It's expertly designed for motor protection with a rated current of 63A.
To ensure peak performance, selection, installation, and usage must adhere strictly to the product manual or relevant national standards.
Note: The N-pole type of a 4P circuit breaker is categorized into A-type and B-type, with B-type as the default if unspecified.

Working Principle: A detailed breakdown of the core mechanism.
The main contact of the molded case circuit breaker can be adeptly closed manually or electrically. Post-closure, the ingenious free release mechanism securely locks the main contact in the closed position. The over
current trip coil and the thermal trip element are intricately connected in series with the main circuit, ensuring responsive protection.
Voltage
release: An essential safety feature for reliable operation.
coil and the power supply are connected in parallel, providing robust and dependable performance.
Cdada Dam2 250A Moulded Case Circuit Breaker Fixed Type MCCB

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now