Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Manual Type |
Still deciding? Get samples of US$ 19/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The DAM3 series stands out with a compact design, surpassing the DAM1 series by offering higher breaking capacity and superior energy efficiency. It's a smart, space-saving solution for modern electrical needs.
Electrical Parameters of DAM3-250 Molded Case Circuit BreakerRated current of frame size Inm [A] | 250 | ||||
Rated current [A] | 100-250 | 100-225 | |||
Number of poles | 2 / 3 / 4 | ||||
Rated operating voltage | (AC)50-60HZ [V] | 400/690 | |||
DC [V] | 250/1000 | ||||
Rated impulse withstand voltage Uimp [KV] | 8 | ||||
Rated insulation voltage Ui [V] | 750 | ||||
Test voltage at industrial frequency for 1 min [V] | 3000 | ||||
Rated ultimate short-circuit breaking capacity Icu [KA] | B | C | N | S | |
(AC)50-60HZ 220/230V [KA] | 30 | 36 | 50 | 75 | |
(AC)50-60HZ 400/415V [KA] | 18 | 25 | 36 | 50 | |
(AC)50-60HZ 690V [KA] | 6 | 8 | 12 | 15 | |
(DC)250V-2 Poles in series | 18 | 22 | 30 | 40 | |
(DC)500V-2 Poles in series | 9 | 12 | 15 | 20 | |
(DC)750V-4 Poles in series | 16 | 18 | 22 | 30 | |
(DC)1000V-4 Poles in series | 13 | 15 | 18 | 25 | |
Rated service short-circuit breaking capacity, Ics [KA] | |||||
(AC)50-60HZ 220/230V [%Icu] | 60% | 60% | 60% | 50% | |
(AC)50-60HZ 400/415V [%Icu] | 60% | 60% | 60% | 50% | |
(AC)50-60HZ 690V [%Icu] | 60% | 60% | 60% | 50% | |
category of utilization (EN 60947-2) | A | ||||
Isolation condition | Bitmap | ||||
Reference standard | IEC/EN 60947-2/GB 14048.2 | ||||
Interchangeability | Bitmap | ||||
Versions | Fixed | Bitmap | |||
Plug-in | Bitmap | ||||
Draw-out | - |
Endurance | Total cycles | 10000 | |
Electrical endurance | 1500 | ||
Mechanical endurance | 8500 | ||
Basic dimensions-fixed version |
3/4 Poies W[mm] | 70(2P) /104 /139 | |
3/4 Poies H[mm] | 59 | 62.5 | |
H1[mm] | 78.5 | 82 | |
3/4 Poies L[mm] | 139 |
Introduction
The DAM3-250 molded case circuit breaker is engineered to automatically interrupt the current flow when it surpasses the preset release threshold. The term 'molded case' refers to the robust plastic insulator that forms the frame of the device, effectively isolating the conductor from the metal grounding components.
Working Principle
Operating the DAM3-250 involves manual or electric closing of the main contact. Once closed, a free release mechanism securely locks the main contact in place. The overcurrent trip coil and thermal trip element are integrated in series with the main circuit, while the undervoltage trip coil is wired in parallel with the power supply. This intricate configuration ensures reliable and efficient circuit protection.