• Dam1-125 125A Circuit Breaker with Kema Certification
  • Dam1-125 125A Circuit Breaker with Kema Certification
  • Dam1-125 125A Circuit Breaker with Kema Certification
  • Dam1-125 125A Circuit Breaker with Kema Certification

Dam1-125 125A Circuit Breaker with Kema Certification

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Arc Chamber
Installation: Fixed
Structure: MCCB
Samples:
US$ 12/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Shanghai, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)

Basic Info.

Model NO.
Dam1-125
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CB, CCC
Cover
BMC Material
Base
BMC Material
Transport Package
Carton
Specification
12.5, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125A
Trademark
CDADA, OEM, ODM
Origin
Shanghai
HS Code
85362000
Production Capacity
40000PCS/Month

Product Description

DAM1-125


Dam1-125 125A Circuit Breaker with Kema Certification


1P,2P,3P,4P 400V/415V Moulded case circuit breaker high quality with ASTA,KEMA,SEMKO,CE,CB,ROHS certificate


Introduction
The DAM1 series circuit breakers are intended for conducting current in normal mode and switching it off at short circuits, overload, inadmissible bucking as well as operational actuation and tripping of electric circuit parts. They are designed for use in electric units having the operative voltage limited to 400V per rated current from 12,5 to 1600A. 

They correspond to the requirements of EN 60947-1, EN 60947-2 

Thermal-Magnetic Circuit Breakers:
Thermal protection function:(For protection under over load conditions) 
Bimetal,  which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing through the breaker. Because, increase of current means increase of heat. In this way, over current protection function of the breaker is fulfilled by bimetal at load currents higher than the rated current

Magnetic protection function (For protection under short circuit
conditions)
Another function of the breaker is to protect the connected circuit against short circuits. Short circuit may occur as a result of contact of phases with each other or contact of phase-ground. Since a very high current shall pass through the cables in case of short circuit, system energy should be broken in a shorter time due to thermal protection. Breaker should perform instant opening to protect load it is connected to. The part fulfilling this function is a mechanical opening mechanism that operates with magnetization caused by the magnetic
area formed by the short circuit current

 

Advantages

 
  • Easy independent installation of auxiliary devices:
    • Alarm contact;
    • Auxiliary contact;
    • Under voltage release;
    • Shunt release;
    • Handle operating mechanism;
    • Electrical operating mechanism;
    • Plug-in device;
    • Draw-out device;.
  • Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting onto an installation panel.
  • With the help of special clamp 125 and 160 units can be installed onto a DIN-rail.
  • Weight and dimensions of these circuit breakers are by 10-20% less than that suggested by other home manufacturers. This fact provides for mounting smaller boxes and panels. Besides, small dimensions make it possible to change old circuit breakers to DAM1.

Application
Moulded case circuit breakers are low-voltage circuit breakers. They meet the installation needs of small users all the way to large industrial substations and power distribution systems. They are commonly applied in steel mills, oil platforms, hospitals, railway systems, airports, computing centers, office buildings, convention centers, theaters, skyscrapers, and other large scale structures.

  
 
Electrical parameters of DAM1 MCCB molded case circuit breaker
 
Thermal-magnetic fixed type MCCB                
Photo Model code   Icu (KA) Ics (KA) Rated Current
-In
Ui(V) Ue(V) Pole Uimp(V)
  DAM1-160 B 25 18.75 10 - 12,5 - 16 - 20 - 25 - 32 - 40 - 50 - 63- 80 - 100 - 125-160A 500V 230V 1P 10000
N 36 27
  DAM1-200 B 25 18.75 10 - 12,5 - 16 - 20 - 25 - 32 - 40 - 50 - 63- 80 - 100 - 125-160(200)A 750V 400V 2P 10000
N 36 27
  DAM1-125 B 25 12.5 10 - 12,5 - 16 - 20 - 25 - 32(30) - 40 - 50 - 63(60) - 80 - 100 - 125A 750V 400V 3P / 4P 10000
N 35 17.5
S 50 37.5
  DAM1-160 B 25 12.5 10- 12,5-16-20 - 25 - 32 - 40  - 50 - 63 - 80 - 100 -125 - 160(150)A 750V 400/415V 3P / 4P 8000
N 35 26.25
S 50 37.5
  DAM1-250 N 35 26.25 63 - 80-100-125 - 160(180) -  200(225) - 250(320)A 750V 400/415V 3P /4P 8000
S 50 37.5
H 65 48.75
G 85 51
  DAM1-630(400) N 35 26.25 250 - 315 (350)- 400 - 500  - 630A 750V 400/415V 3P /4P 8000
S 50 37.5
H 70 52.5
G 85 52.5
  DAM1-800 N 35 35 400 - 500 - 630 (700)- 800 -1000A 750V 400/415V 3P /4P 8000
S 50 37.5
H 70 52.5
G 85 52.5
  DAM1-1600 S 65 50 800 -1000 - 1250 - 1600A 750V 400V 3P / 4P 8000
H 85 50
G 100 50
·Icu:O-t-CO test(O:Open maneuver,CO:Close-Open maneuver,t:Waiting duration)
·Ics:O-t-CO-t-CO test(O:open maneuver,CO:Close-Open maneuver,t:Waiting duration)
ON/I Position: It indicates that contacts of the breaker are closed. In this position, the breaker lever is in the top position
TRIP Position: It indicates that the breaker is opened due to any failure (over load or short circuit). In this case, breaker lever is in the middle position between ON and OFF positions. In order to take the breaker, which is in trip position, to ON position; push the breaker lever downwards as shown by the OFF sign
Breaker shall be set with "click" sound.After that, pull the lever as shown by ON sign to close the breaker 
OFF/0 Position: It indicates that contacts of the breaker are open. In this way, the breaker lever is in the bottom position.

Physical parameters of DAM1-125 MCCB molded case circuit breaker
 
Category (EN 60947-2/IEC 60947-2) Endurance  
Model Pole Dielectric Propery (V) lonization distance                                                                                                              (mm) Total Cycles Electrical Life Mechanical Life Main circuit Auxiliary circuit
DAM1-160 1P 2500 ≤30/0 20000 3000 17000 A/0 AC-15
DAM1-200 2P 2500 ≤30/0 15000 2500 12500 A/0 AC-15
DAM1-125 3P / 4P 2500 ≤30/0 8000 1000 7000 A/0 AC-15
DAM1-160 3P / 4P 3000 ≤30/0 8000 1000 7000 A/0 AC-15
DAM1-250 3P /4P 3000 ≤30/0 8000 1000 7000 A/B AC-15
DAM1-630(400) 3P /4P 3000 ≤60/0 5000 1000 4000 A/B AC-15
DAM1-800 3P /4P 3000 ≤80/0 5000 1000 4000 A/B AC-15
DAM1-1600 3P / 4P 3000 ≤80/0 3000 500 2500 A/B AC-15



Size of MCCB molded case circuit breaker


 
Model Pole Outline dimension
(LXWXH)
DAM1-160 1P 120x30x70mm
DAM1-200 2P 120x60x70mm
DAM1-125 3P 120x76x70mm
 4P 120x101x70mm
DAM1-160 3P 120x90x70mm
 4P 120x120x70mm
DAM1-250 3P 170x105x103.5mm
 4P 170x140x103.5mm
DAM1-630(400) 3P 254x140x103.5mm
 4P 254x184x103.5mm
DAM1-800 3P 268x210x103.5mm
 4P 268x280x103.5mm
DAM1-1600 3P 410x210x138.5mm
 4P 410x280x138.5mm


Working principle
The main contact of the molded case circuit breaker is manual manipulation or electric closing. After the main contact is closed, the free release mechanism locks the main contact into the closing position. The over current trip coil and the thermal trip element are connected in series with the main circuit. The under voltage release coil and the power supply are connected in parallel.