Low Voltage MCCB Fixed Breaker 250A with Moulded Case

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 10/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Low Voltage MCCB Fixed Breaker 250A with Moulded Case
  • Low Voltage MCCB Fixed Breaker 250A with Moulded Case
  • Low Voltage MCCB Fixed Breaker 250A with Moulded Case
  • Low Voltage MCCB Fixed Breaker 250A with Moulded Case
  • Low Voltage MCCB Fixed Breaker 250A with Moulded Case
  • Low Voltage MCCB Fixed Breaker 250A with Moulded Case
Find Similar Products

Basic Info.

Model NO.
CM1-125
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Transport Package
Carton
Specification
12.5, 16, 20, 25, 32, 40, 50, 70, 80, 100A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
85362000
Production Capacity
10000PCS/Month

Product Description

Low Voltage MCCB Fixed Breaker 250A with Moulded Case


Introducing the DAM2 series Moulded Case Circuit Breaker, a paragon of technological excellence, crafted with meticulous precision using cutting-edge international technology. These trailblazing breakers are celebrated for their remarkably compact design, outstanding breaking capacity, reduced arc-over distance, and robust shake-proof construction. These characteristics make them the ideal choice for a plethora of applications, whether on land or at sea.

Application

The DAM2 (CM1) series circuit breaker stands as a robust powerhouse, featuring an impressive rated insulation voltage of 800V. Expertly engineered for AC distribution networks at 50Hz/60Hz, it manages a rated working voltage of up to 690V and a rated current of up to 1250A. Perfect for power distribution and circuit protection, it safeguards equipment against overloads, short-circuits, under-voltage, and more. Capable of accommodating infrequent circuit conversions and motor starts, it offers remarkable adaptability. Installable in both vertical and horizontal orientations, it showcases unparalleled usability. Designated for isolation by the symbol " ", the DAM2 MCCB strictly conforms to IEC60947-2 standards for low-voltage switchgear and control equipment, affirming its status as an exemplary circuit breaker.

Low Voltage MCCB Fixed Breaker 250A with Moulded CaseLow Voltage MCCB Fixed Breaker 250A with Moulded Case

Normal operating conditions

1. Ambient air temperature: Ensure maintenance between -5ºC to +40ºC, with the daily average not surpassing +35ºC.
2. Altitude: Confirm installation site altitude remains within 2000 meters to ensure optimal performance.
3. Atmospheric conditions: At +40ºC, relative humidity should not exceed 50%, although higher humidity is permissible at lower temperatures. The maximum average relative humidity is 90%, with a minimum average monthly temperature of +25ºC, considering possible condensation due to temperature variations.
4. Pollution Degree: 3.

Selection of instructions

Classified by pole types:
Type A: N-pole without over-current release components, remains continuously connected, independent from the other three poles.
Type B: N-pole without over-current release components, operates in concert with the other three poles (N-pole initiates prior to deactivation).
Type C: N-pole with over-current release components, functions cohesively with the other three poles (N-pole initiates before deactivation).

Classified by rated current of over-current release:
DAM2-63 MCCB Available in a comprehensive selection of nine ratings: 6, 10, 16, 20, 25, 32, 40, 50, and 63 A.
DAM2-100 MCCB Available in nine versatile ratings: 16, 20, 25, 32, 40, 50, 63, 80, and 100 A.
DAM2-250 MCCB Available in a solid range of eight ratings: 100, 125, 140, 160, 180, 200, 225, and 250 A.
DAM2-400 MCCB Available in five distinct ratings: 225, 250, 315, 350, and 400 A.
DAM2-630 MCCB Available in three robust ratings: 400, 500, and 630 A.
DAM2-800 MCCB Introducing a versatile array of robust options: available in impressive ratings of 630, 700, and 800 A. Each variant is tailored to meet your specific needs for optimal electrical performance.
DAM2-1250 MCCB: Discover unparalleled flexibility with our remarkable selection, boasting ratings of 800, 1000, and 1250 A. Designed to meet the most stringent demands, these circuit breakers empower your setup with unmatched reliability and strength.
Remark: Please be aware that our exclusive 6A version is expertly engineered in the electromagnetic (instantaneous) type. Due to its specialized nature, it is not recommended for general applications, ensuring safety and specificity in its use.
Wiring Options: Discover seamless adaptability in your installations with our versatile selection: choose from front-of-board, back-of-board, or insertion type wiring. Effortlessly tailor your configuration to match your precise requirements with unparalleled flexibility.
Over-Current Release Patterns: Choose from our expertly crafted options: the thermodynamic-electromagnetic (dual) type or the electromagnetic (instantaneous) type. Each configuration is meticulously designed to meet diverse application needs, guaranteeing superior performance and precision.
Outfit Options: Tailor your system with ease by selecting circuit breakers with or without additional outfits. This customizable aspect ensures seamless alignment with your specific application requirements, enhancing both functionality and efficiency.
Outfit Details: Enhance your system with a comprehensive suite of accessories. Elevate inner functionalities with options such as shunt release, under-voltage release, auxiliary contact, and alarm contact. Explore advanced outer accessories like the turning handle and power-driven mechanisms for exceptional integration and functionality.
Breaking Capacity: Experience a broad range of breaking capacities, expertly engineered in L-standard, M-second high, and H-high categories. Each type is precisely crafted to deliver exceptional accuracy and performance across various applications.

Low Voltage MCCB Fixed Breaker 250A with Moulded CaseLow Voltage MCCB Fixed Breaker 250A with Moulded Case


Technical Parameters

1. Instantaneous Action Characteristics: For distribution circuit breakers, benefit from a precise setting value of 10In±20%. The DAM2-1250 model is fine-tuned at 7In±20%. Motor protection circuit breakers offer steadfast performance with a setting value of 12In±20%.
2. Rated Values: For a detailed understanding, refer to Table 2, which comprehensively presents the rated values of our circuit breakers. Equip yourself with all the essential specifications needed for informed decisions.
3. Ambient Temperature: At an ambient temperature of +40ºC, explore the detailed over-current release action characteristics for distribution circuit breakers in Table 3, and for motor protection circuit breakers in Table 4. Ensure optimal performance under various conditions.

Rated Value: Immerse yourself in the detailed specifications of the circuit breaker's rated value. Each aspect is engineered for reliability and efficiency, ensuring superior performance across a wide array of scenarios.

Model Pole Rated current (A) Rated
operating
voltage (V)
Rated
insulation
voltage (V)
Rated ultimate short - circuit breaking capacity (Icu) Flashover
distance(mm)
Test voltage (V) Icu (kA) Ics (kA)
DAM2L-63 3 10,16,20,25,
32,40,50,63
400 500 400×1.10 25 18 0
DAM2M-63 3,4 50 35
DAM2L-100 3,4 16,20,25,32,40,
50,63,80,100
400 800 30 22 ≤50
DAM2M-100 2,3,4 50 35
DAM2H-100 3 85 50
DAM2L-100 3,4 690 10 5
DAM2M-100 2,3,4 20 10
DAM2L-225 3,4 100,125,140,
160,180,200,225
400 800 35 25
TXCM1-225 2,3,4 50 35
DAM2H-225 3 85 50
DAM2L-225 3,4 690 10 5
DAM2M-225 2,3,4 20 10
DAM2L-400 3 225,250,315,
350,400
400 800 50 35 ≤100
DAM2M-400 3,4 65 42
DAM2H-400 3 100 65
DAM2L-400 3 690 15 8
DAM2M-400 3,4 20 10
DAM2L-630 3 400,500,630 400 800 50 35
DAM2M-630 3,4 65 42
DAM2H-630 3 100 65
DAM2L-630 3 6910 15 8
DAM2M-630 3,4 20 10
DAM2M-800 3 630,700,800 400 800 75 50
DAM2H-800 3 100 65
DAM2M-800 3 4690 30 15
DAM2-1250 3 800,1000,1250 400 800 85 42
DAM2-1250 3 690 25 12.5

Note: For 2-pole and 4-pole circuit breakers categorized into L, M, and H types, the breaking index for each type mirrors that of the M-type, ensuring uniformity and consistent performance.

Inverse Time Breaking Action: Explore the characteristics of over-current release tailored for power distribution, delivering reliable protection even when all poles are energized simultaneously.

No. Test current I/In Set time Initial state
1 Conventional non-tripping current 1.05 2h(In>63A),1h(In≤63A) Cold
2 Conventional non-tripping current 1.30 2h(In>63A),1h(In≤63A) Immediately after Test 1

Instantaneous Action Characteristics: Distribution circuit breakers possess a precise setting value of 10In±20%, while motor protection circuit breakers maintain a robust 12In±20%, offering unwavering protection and reliability.

Inverse Time Breaking Action: Delve into the over-current release characteristics crafted for motor protection, ensuring dependable safeguarding with concurrent power across all poles.

No. I/In Set time Initial state Remark
1 1.0 >2h Cold  
2 1.2 ≤2h Immediately after Test 1  
3 1.5 ≤4min Cold 10≤n≤225
≤8min 225 < in ≤ 630
4 7.2 4s≤T≤10s Cold 10≤In≤225
6s≤T≤20s 225 < in ≤ 630

Accessories

1. Internal Accessories of Circuit Breakers

1.1 Shunt Release
Shunt Release Voltage: Achieve optimal efficiency with a rated control supply voltage of AC50Hz, 230V, 400V, or DC110V, 220V, 24V. It ensures reliable circuit breaker operation within a 70%~110% voltage range, guaranteeing consistent performance.

DC24V Shunt Release: Ensure dependable functionality by adhering to the prescribed maximum copper wire length, essential for optimal operational efficiency.

Rated control
supply voltage Uc(DC24V)/Conductor area
1.5mm² 2.5mm²
100%Uc
85%Uc
150m
100m
250m
160m

Design Recommendations: Should table specifications be unmet, we recommend designing the shunt release control circuit as illustrated, ensuring assured effectiveness and reliability.

1.2 Under-Voltage Release

Under-Voltage Operation: Discover the pinnacle of reliability with our meticulously crafted under-voltage release. This advanced feature is engineered to ensure seamless breaker performance amidst voltage fluctuations ranging from 70% to 35% of the rated voltage, offering steadfast protection and unyielding peace of mind.
Under-Voltage Protection: Our cutting-edge technology vigilantly prevents unsafe circuit breaker closures when the voltage drops below 35% of the rated threshold. It safeguards secure closures above 85%, ensuring a harmonious blend of safety and consistent performance in every operation.
Closing Mechanism: Our sophisticated under-voltage release mechanism guarantees robust circuit breaker closures at supply voltages exceeding 85% of the rated value. This provides an exceptional safety net, ensuring flawless operations and unparalleled protection for your systems.
Under-Voltage Ratings: Engineered with ratings at AC50Hz for both 230V and 400V, our breakers assure unwavering performance across diverse applications, delivering peace of mind with every single use.
400V.
Special Note: Designed with precision, our circuit breakers operate seamlessly at the rated voltage, thanks to the under-voltage release function. This ensures dependable opening and closing operations, reinforcing safety in every action.
normally.

1.3 Pre-Paid Meter Dedicated Release

The pre-paid meter dedicated release is engineered at AC230/50Hz, offering exceptional performance over an impressive range of 65% to 110% of Ue. Remarkably, the circuit breaker initiates a precisely timed opening from 0.5 to 2 seconds once control disengagement occurs, providing unmatched safety and reliability for your peace of mind.

Wiring Diagram for Pre-Paid Meter Dedicated Release

1.4 Rated Values of Auxiliary Contacts and Alarm Contacts (Refer to Table 5)

Classification Conventional thermal current (Ith) Rated current when

 

AC 400V Ie(AC-15)

Rated current when

 

DC 220V Ie(DC-13)

Auxiliary contact 3 0.4 0.15
Alarm contact 3 0.3 0.15

a. Auxiliary Contact

b. Alarm Contact
Our alarm contacts are ingeniously crafted to remain inactive during normal operations. They transition smoothly between normal open and normal closed states solely during free or fault tripping events, ensuring timely and accurate alerts only when truly necessary.

2. External Accessories for Circuit Breakers

2.1 Motor Operating Mechanism: Explore comprehensive specifications, including precise rated values and corresponding codes, thoroughly detailed in Table 6.

Category/Model DAM2-63. 125. 250 DAM2-400. 630. 800. 1250
Structure type Electromagnet Motor
AC voltage code AC50Hz,230V,400 AC50Hz,230V,400
DC voltage code DC110V,220V DC110V,220V

NOTE: After a circuit breaker trips via an electric operating mechanism, ensure to reset the circuit breaker before any reclosing attempts to maintain consistent and safe operations.

Principle Diagram for Opening and Closing of DAM2-63,100,225 Electric Operating Mechanism (AC)

Principle Diagram for Opening and Closing of DAM2-400,630,800,1250 Electric Operating Mechanism (AC)

2.2 Installation Dimensions for Manual Operating Mechanism (Refer to Table 10)
Diagram of Handle Mounting Hole for DAM2-63~800

Total Height of Electric/Manual Operating Mechanism of Circuit Breaker (mm) (Refer to Table 12)

Model Total height of electric
operating mechanism H
Installation dimensions

 

of manual operating mechanism H

DAM2L-63 155 49
DAM2M/H-63 164 49
DAM2L-100 152 51
DAM2M/H-100 170 51
DAM2L-225 182 54
DAM2M/H-225 199 54
DAM2L/M/H-400 255 88
DAM2M/H-630 262 89
DAM2M/H-800 261 96
DAM2H-1250 290 103

Quick Selection Table for DAM2 Series Molded Case Circuit Breakers

Corresponding
letters
Function name Function corresponding to the model
a Model features DAM2 Molded Case

 

Circuit Breaker

b Frame rated current code 63A,100A,225A,

 

400A,630A,800A,

1250A

c Breaking capacity characteristic
code
L-standard breaking type;

 

M-second high breaking type;

H-high breaking type

d Operation mode code No code for handle operation;

 

P for electric operation;

Z for turning handle operation

e Pole 2-two poles;

 

3-three poles;

4-four poles

f Release name 2 Electromagnetic release;

 

3 Double release

g Accessory 00 Without accessory
08 Alarm contact
10 Shunt release
20 Auxiliary contact
30 Undervoltage release
40 Shunt release, Auxiliary contact
50 Shunt release, Undervoltage release
60 Two sets of auxiliary contacts
70 Auxiliary contact, Undervoltage release
18 Shunt release, Alarm contact
28 Auxiliary contact, Alarm contact
38 Undervoltage release, Alarm contact
48 Shunt release, Auxiliary contact, Alarm contact
58 Shunt release, Undervoltage release, Alarm contact
68 Two sets of auxiliary contacts, Alarm contact
78 Auxiliary contact, Undervoltage release, Alarm contact
10Y Pre-paid meter dedicated release
40Y Pre-paid meter dedicated release, Auxiliary contact
50Y Pre-paid meter dedicated release, Auxiliary contact, Undervoltage release
18Y Pre-paid meter dedicated release, Alarm contact
48Y Pre-paid meter dedicated release, Auxiliary contact, Alarm contact
58Y Pre-paid meter dedicated release, Undervoltage release, Alarm contact
h Application No code for distribution;

 

2 for motor protection

i Conventional products No code;

 

T for transparent cover products

j Amperage 10,16,20,25,32,63,80,100,125,160,180,200
,225,250,315,350,400,500,630,700,800,1000
,1250

Example: DAM2L-100 / 33102 63A exemplifies a DAM2-type molded case circuit breaker. This impressive model boasts a frame rated current of 100A, standard breaking capacity, handle operation, 3 poles, dual release, and shunt release. It is meticulously optimized for motor protection with a rated current of 63A.
For unparalleled performance, ensure all selection, installation, and usage strictly adhere to the product manual or relevant national standards.
Note: The N-pole type of a 4P circuit breaker is classified into A-type and B-type. In the absence of specific instructions, the default designation is B-type.

Working Principle
The primary contact within the molded case circuit breaker can be securely locked in place, whether through manual or electrical means. Once closed, this innovative free release mechanism robustly retains the main contact, ensuring a steadfast and trustworthy closed position. The over...
The trip coil for current and the thermal trip element are masterfully aligned in a strategic series within the main circuit. This meticulous arrangement is crafted to deliver peak performance and unwavering reliability for your electrical systems, providing protection against potential interruptions.
voltage
release
The coil and power supply are beautifully arranged in a harmonious parallel configuration. This carefully executed design ensures flawless operation, significantly boosting the efficiency and reliability of your power systems.
Low Voltage MCCB Fixed Breaker 250A with Moulded Case

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier