• Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved
  • Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved
  • Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved
  • Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved
  • Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved
  • Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved

Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: Arc Chamber
Installation: Fixed
Structure: MCB
Samples:
US$ 4/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Shanghai, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)

Basic Info.

Model NO.
dabl-63 1p+n
Poles Number
1p+N
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CB, CCC
Release Type
Electronic Type
Rated Residual Current Motion
10mA,30mA,100mA,300mA
Residual Leakage Current Curve
a,AC,S Type
Transport Package
Carton
Specification
6, 10, 16, 20, 25, 32, 40, 50, 63A
Trademark
CDADA, OEM, ODM
Origin
Shanghai
HS Code
85362000
Production Capacity
200000PCS/Month

Product Description

DABL-63 6kA 10kA Electronic Residual Current Device RCBO Circuit Breaker

Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved

Introduction
The DABL-63 6kA 10kA Electronic Residual Current Circuit Breaker, meticulously crafted by DaDa Electric's expert engineers, offers unparalleled stability, precise protection, rapid response time, and exceptional breaking capacity-all encapsulated in a compact unit. Adhering to GB 10963 and IEC60898 standards, these circuit breakers represent the pinnacle of quality and reliability.

Ideal for overload protection, the DABL-63 circuit breakers are commonly deployed to safeguard contactors, relays, and various other electrical equipment, ensuring optimal performance and safety.

Main functions: short circuit protection, overload protection, and isolation.

Model
DABL-63 1P+N/2P RCBO Circuit Breaker
Rated current Rated frequency Rated operating voltage Rated residual current Rated insulation voltage Impulse withstand voltage Instantaneous trip type Rated breaking capacity W*H*L
6-63A 50-60Hz 230/400V 10,30,100,300A 500V 6KV B/C/D DABL-63 10KA, DABL-63 6KA 36/54mm*80.4mm*72mm
 

Technical parameter of DABL-40 Electronic Residual Current Circuit Breaker
Protection grade: IP20
Flame retardant grade: Grade 2
Mechanical Endurance: 12,000 cycles
Electrical Endurance: 6,000 cycles
Suitable Electric Wire: 1~25mm²2
Operating Temperature: -5~+40ºC
Altitude: ≤2000 meters
Relative Humidity: +20ºC, ≤90%; +40ºC, ≤50%
Pollution Degree: 2
Installation Environment: Avoid areas with significant shock and vibration.
Installation Grade: Grade II, Grade III

Installable Accessories for DABL-63 Electronic Residual Current Circuit Breaker
Auxiliary contact, alarm contact, shunt trip, undervoltage trip, overvoltage trip

Advantages

· Incorporates a combined circuit with an advanced electronic module for differential protection, seamlessly integrated with the DAB7-63 series circuit breaker.
· Provides the most sensitive electric shock hazard protection against direct contact with live parts.
· Features an independent contact position indicator for enhanced safety.
· Operates reliably across a wide temperature range from -25 to +40°C.
· Terminal clamp notches are designed to reduce thermal losses and improve the mechanical stability of connections.
· Includes a 'TEST' button for verifying device functionality and connection accuracy.
· Compact DABL dimensions are akin to a 2-modular item, optimized through efficient component placement.
· Enhanced 6 kA capability allows for the use of AVDTs as primary protection switches.
 
Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved

 
Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved
 
Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved
 
Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved
 
Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved
 
Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved

 
Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved

 
Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved
 
Dabl-63 6ka 1p+N RCBO 30mA Residual Current Circuit Breaker AC Type Approved
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now