10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 4/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • 10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA
  • 10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA
  • 10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA
  • 10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA
  • 10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA
  • 10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA
Find Similar Products

Basic Info.

Model NO.
dabl-63 1p+n
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCB
Poles Number
1p+N
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CB, CCC
Release Type
Electronic Type
Rated Residual Current Motion
10mA,30mA,100mA,300mA
Residual Leakage Current Curve
a,AC,S Type
Transport Package
Carton
Specification
6, 10, 16, 20, 25, 32, 40, 50, 63A
Trademark
CDADA, OEM, ODM
Origin
Shanghai
HS Code
85362000
Production Capacity
200000PCS/Month

Product Description

DABL-63 6kA 10kA Electronic Residual Current Device RCBO Circuit Breaker

10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA

Introduction
Introducing the DABL-63 6kA 10kA electronic residual current circuit breaker, meticulously crafted by Dada engineers for unmatched stability and precision. This compact marvel offers rapid response times, superior protection, and an impressive breaking capacity. Adhering to GB 10963 and IEC60898 standards, the DABL-63 sets a new benchmark in circuit breaker technology.

Widely utilized to safeguard contactors, relays, and various electrical equipment, these circuit breakers are indispensable for overload protection.

Key functions include: short circuit protection, overload protection, and isolation.

Model
DABL-63 1P+N/2P RCBO Circuit Breaker
Rated current Rated frequency Rated operating voltage Rated residual current Rated insulation voltage Impulse withstand voltage Instantaneous trip type Rated breaking capacity W*H*L
6-63A 50-60Hz 230/400V 10,30,100,300A 500V 6KV B/C/D DABL-63 10KA, DABL-63 6KA 36/54mm*80.4mm*72mm
 

Technical Parameters of DABL-40 Electronic Residual Current Circuit Breaker
Protection Grade: IP20
Flame Retardant Grade: Grade 2
Mechanical Endurance: 12,000 operations
Electrical Endurance: 6,000 operations
Compatible Electric Wire: 1~25mmInstallation Mode: 2
Operating Temperature: -5~+40ºC
Maximum Altitude: ≤2000m
Relative Humidity: +20ºC, ≤90%; +40ºC, ≤50%
Pollution Class: 2
Installation Environment: Avoid noticeable shock and vibration
Installation Grades: Grade II, Grade III

Compatible Accessories for DABL-63 Electronic Residual Current Circuit Breaker
Available Accessories: Auxiliary contact, alarm contact, shunt trip, undervoltage trip, overvoltage trip

Advantages

· Combines differential protection with the integrated circuit breaker of the DAB7-63 series for unmatched efficiency.
· Delivers exceptional electric shock hazard protection during direct contact with conductive parts.
· Features an independent contact position indicator for enhanced safety.
· Operates within a broad temperature range from -25 to +40°С, ensuring reliability in diverse environments.
· Terminal clamp notches minimize thermal losses and enhance mechanical stability of connections.
· Equipped with a 'TEST' button to verify the device's functionality and connection accuracy.
· Compact DABL dimensions align with a 2-modular item design, thanks to efficient element placement.
· Enhanced 6 kA capability makes it ideal for installing AVDTs as primary protection switches.
 
10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA

 
10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA
 
10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA
 
10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA
 
10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA
 
10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA

 
10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA

 
10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA
 
10ka RCBO 4p Residual Current Circuit Breaker 63A Electronic 30mA
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier