Arc Fault Dection Devices-Afddwith Leakage Protection Afddle

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Arc Fault Dection Devices-Afddwith Leakage Protection Afddle
  • Arc Fault Dection Devices-Afddwith Leakage Protection Afddle
  • Arc Fault Dection Devices-Afddwith Leakage Protection Afddle
  • Arc Fault Dection Devices-Afddwith Leakage Protection Afddle
  • Arc Fault Dection Devices-Afddwith Leakage Protection Afddle
Find Similar Products

Basic Info.

Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCB
Poles Number
3p+N
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CB, CCC
Release Type
Electromagnetic Type
Rated Residual Current Motion
10mA,30mA,100mA,300mA
Residual Leakage Current Curve
a,AC,S Type
Transport Package
Carton
Specification
6, 10, 16, 20, 25, 32, 40, 50, 63A
Trademark
CDADA, OEM, ODM
Origin
Shanghai
HS Code
85362000
Production Capacity
200000PCS/Month

Product Description


Arc Fault Dection Devices-Afddwith Leakage Protection Afddle


I) Product introduction

The arc fault dectection device (hereinafter referred to as AFDD/AFDDLE) can effectively detect the fault arc in the access line, including the fault parallel arc and the fault series arc. When the fault arc causing fire is detected in the line, it can perform the function of disconnection and power-off to realize the purpose of early warning of fire. The arc fault dectection device is applicable to the electrical lines of 10kW and below in industrial and civil buildings. The length of the protection line should not be greater than 100m. The products comply with GB/t31143-2014 IEC62602 standard and can be applied to nursing homes, schools, commercial buildings, hotels, factories, warehouses, libraries, offices, family houses, and entertainment places.

II)Technical Data Sheet
 
Items Value
Model AFDD without leakage protection/AFDDLE with leakage protection
Working power supply Rated voltage: AC230V
Rated frequency 50Hz
Monitoring alarm Fault arc alarm (load below AC63A)
Voltage Rated value AC230V
electric current Rated value: AC63A and below
Overall dimensions 82*35.2*62mm
Installation method 35mm guide rail installation
Run indicator Normal operation, the indicator flashes
SET Set button
Breaking capacity Rated short-circuit breaking capacity ICN (KA): 6
Protection level IP20
Wiring capacity 1~25mm
Outlet characteristics C,D
Electrostatic discharge resistance Air discharge > 8; Contact discharge > 6
Pulse group anti-interference 6KA
Surge impact interference 4KA
Operating ambient temperature -23~+55ºC
Damp heat resistance Type 2
class of pollution 2
Installation type Level M
altitude 2000m
Installation environment Ground without significant vibration and impact
Mechanical life 20000cycles
Electrical life 10000cycles

III) Product Settings

T key: Test key - Multi-functional press key
Green light status: Running status
Press the "T key" and release it quickly (note that it is triggered by release) to test the  the breaking function of AFDD protection.
 Red light flashing status: Fault arc alarm status.
The alarm will be immediately lifted after pressing the "T key"
Set the AFD detection mode:
When the green light is on, hold down the "T key "for about 3 seconds and the green light will go off. This indicates that you have entered the Settings status. Press the "T key" again, and the green light will flash to indicate the current working mode. It switches once each time it is pressed!
There are four working modes in total:
  1. Flash once: Anti-interference mode
  2. Flash twice: Slow mode
  3. Flash three times: Standard mode
  4. Flash four times: Enhanced mode (not a dedicated scene, not recommended for use)

It takes effect immediately after switching. Wait for 10 seconds and it will automatically exit the setting state. You can also long press the "T key" to exit.
Arc Fault Dection Devices-Afddwith Leakage Protection Afddle
IV)   Wiring diagram
With leakage AFDDLE                               Without leakage AFDD

Arc Fault Dection Devices-Afddwith Leakage Protection Afddle
Arc Fault Dection Devices-Afddwith Leakage Protection Afddle

V)   Product outline dimension and structure definition