Fixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming Material

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 26/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Fixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming Material
  • Fixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming Material
  • Fixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming Material
  • Fixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming Material
  • Fixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming Material
Find Similar Products

Basic Info.

Model NO.
DAM1-250
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
ISO9001-2000, CE, CB, CCC, Asta, Semko, RoHS
Base
BMC Unflaming Material
Rated Insulation Voltage
1000V
Rated Operation Voltage
400/415V
Outline Dimension
170X105X103.5mm
Transport Package
Carton
Specification
63, 80, 100, 125, 160, 200, 250, 315A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
8536200000
Production Capacity
20000PCS/Month

Product Description

Introduction

The DAM1 series circuit breakers are meticulously engineered to conduct electrical current seamlessly under normal conditions and to provide a reliable shutdown during emergencies such as short circuits, overloads, and inadmissible bucking. Designed for operational actuation and the tripping of electric circuit parts, these breakers are ideal for electric units with an operative voltage of up to 400V and cater to rated currents ranging from 12.5A to 1600A.

These circuit breakers fully comply with the rigorous standards of EN 60947-1 and EN 60947-2, ensuring unmatched performance and safety.

Thermal-Magnetic Circuit Breakers:

Thermal Protection Function: (Designed to safeguard against overload conditions)
The bimetal element, crucial for thermal protection, is constructed from two metals with different thermal expansion coefficients. When heated, it bends towards the metal with the lesser expansion rate, triggering a notch that releases the breaker mechanism and disables the circuit. The bending speed is directly proportional to the current size, meaning higher currents generate more heat, enabling the bimetal to provide effective overload protection at currents exceeding the rated value.
Magnetic Protection Function(For safeguarding against short circuit conditions) Another vital function of the breaker is toshield the connected circuit from shortcircuits. Short circuit incidents can arisefrom the contact between phase wires or between a phase wire and the ground.Given that an extremely high current flows through the cables during a short circuit, the system's power supplymust be interrupted swiftly to prevent thermal damage. The breakermust execute an instant opening to safeguardthe connected load. This function is performed by amechanical opening mechanism, whichactivates through magnetization, induced by the magnetic field generated by the short circuit current.This ensures rapid and reliable protection.
Thermal-Magnetic fixed type Circuit Breakers  
Model DAM1-250
Breaking Capacity Code N S H G
Rated Current of Frame size- Inm                                                                    (A) 250A
Rated Current-In(40,50 or 55ºC)                                                                      (A) 63 - 80-100-125 - 160(180) -  200(225) - 250(320)A
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz                                                    (V) 750V
Rated operation Voltage  -Ue(a.c.) 50-60Hz                                                    (V) 400/415V
Number of Pole 3P /4P
Rated ultimate short Circuit breaking Capacity  kA  Icu AC400V/50Hz O-CO          (KA) 35 50 65 85
Rated service short Circuit breaking Capacity  kA  Ics AC400V/50Hz O-CO-CO     (KA) 26.25 37.5 48.75 51
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO         (KA) 77/0.25 114/0.25 143/0.2 178/0.2
Rated impulse withstand Voltage -Uimp                                                                            (V) 8000
Dielectric Propery (V) 3000
lonization distance                                                                                                              (mm) 30/0
Endurance Total Cycles 8000
Electrical Life 1000
Mechanical Life 7000
Over Current trip Thermal and Magnetic release fix type
Category (EN 60947-2/IEC 60947-2) Main circuit A/B
Auxiliary circuit AC-15
Under Voltage Release 
Shunt Release
Auxiliary Contact
Alarm Contact
Auxiliary Contact and Alarm Contact
Handle Operation Mechanism
Electrical Operastion Mechanism 
DIN clips -
Terminal cover    
Phase seperator    
Extention Handle     -
  W (mm) 3P 105
4P 140
L (mm) 3P 170
4P 170
H (mm) 3P 103.5
4P 103.5
Weight Fixed version 3P/4P 2.7/3.5 41.5/5.5
Plug-in version 3P/4P 3.2/4.2 4.6/6
Draw out version 3P/4P 3.6/4.6 5/6.4

Fixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming MaterialFixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming MaterialFixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming MaterialFixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming MaterialFixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming MaterialFixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming MaterialFixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming MaterialFixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming MaterialFixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming MaterialFixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming MaterialFixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming MaterialFixed Type MCCB 3p 250A Distribution Breaker with BMC Unflaming Material