Dam2 Moulded Case Circuit Breaker for Low Voltage Systems

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 10/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Dam2 Moulded Case Circuit Breaker for Low Voltage Systems
  • Dam2 Moulded Case Circuit Breaker for Low Voltage Systems
  • Dam2 Moulded Case Circuit Breaker for Low Voltage Systems
  • Dam2 Moulded Case Circuit Breaker for Low Voltage Systems
  • Dam2 Moulded Case Circuit Breaker for Low Voltage Systems
  • Dam2 Moulded Case Circuit Breaker for Low Voltage Systems
Find Similar Products

Basic Info.

Model NO.
CM1-125
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Transport Package
Carton
Specification
12.5, 16, 20, 25, 32, 40, 50, 70, 80, 100A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
85362000
Production Capacity
10000PCS/Month

Product Description

Dam2 Moulded Case Circuit Breaker for Low Voltage Systems


Introducing the remarkable DAM2 series Moulded Case Circuit Breaker, where the pinnacle of technological advancement meets precision engineering. These sophisticated circuit breakers are crafted with state-of-the-art international technology to ensure unparalleled performance and reliability. Their compact design, exceptional breaking capacity, optimized arc-over distance, and robust shake-proof construction make them the ideal choice for a wide variety of applications, whether on land or at sea.

Application

The DAM2 (CM1) series circuit breaker stands as a powerhouse solution, boasting a rated insulation voltage of 800V. Designed for AC distribution networks at 50Hz/60Hz, it supports a rated working voltage of up to 690V with a current capacity reaching up to 1250A. It excels in power distribution and circuit protection, offering a comprehensive shield against overloads, short-circuits, and under-voltage. Its versatility is further demonstrated by its suitability for infrequent circuit conversions and motor starts, as well as flexibility in both vertical and horizontal installations. Distinguished by the isolation symbol "", the DAM2 MCCB adheres to IEC60947-2 standards for low-voltage switchgear and control equipment, solidifying its position as a leading circuit breaker.

Dam2 Moulded Case Circuit Breaker for Low Voltage SystemsDam2 Moulded Case Circuit Breaker for Low Voltage Systems

Normal operating conditions

1. Ambient air temperature: Maintain a consistent range from -5ºC to +40ºC, ensuring the daily average does not exceed +35ºC for optimal operation.
2. Altitude: Install at a site not exceeding 2000 meters in altitude to guarantee optimal performance and reliability.
3. Atmospheric conditions: At +40ºC, keep relative humidity under 50%. Higher humidity is acceptable at lower temperatures, with a maximum average relative humidity of 90%. Ensure the minimum average monthly temperature remains at +25ºC to accommodate condensation from temperature swings.
4. Pollution Degree: 3.

Selection of instructions

Classified by pole types:
Type A: The N-pole remains uninterrupted with no over-current release components, functioning independently of the other three poles.
Type B: The N-pole, lacking over-current release components, operates in unison with the other three poles, activating before they disengage.
Type C: Featuring over-current release components, the N-pole operates synchronously with the other poles, initiating before their deactivation.

Classified by rated current of over-current release:
DAM2-63 MCCB This series is offered in a broad spectrum of nine ratings: 6, 10, 16, 20, 25, 32, 40, 50, and 63 A, catering to a wide range of demands.
DAM2-100 MCCB Available in nine adaptable ratings: 16, 20, 25, 32, 40, 50, 63, 80, and 100 A, ensuring versatility and superior performance.
DAM2-250 MCCB Featuring a robust selection of seven ratings: 100, 125, 140, 160, 180, 200, 225, and 250 A, engineered for powerful performance capabilities.
DAM2-400 MCCB Available in five carefully curated ratings: 225, 250, 315, 350, and 400 A, offering customized solutions for various needs.
DAM2-630 MCCB Unleash unparalleled performance with our circuit breakers, available in three robust ratings: 400, 500, and 630 A. Designed to deliver exceptional reliability and strength, our breakers are the epitome of superior engineering.
DAM2-800 MCCB Explore unparalleled options with our formidable 250A Fixed Type Circuit Breaker. Offered in three dynamic ratings-630, 700, and 800 A-these breakers are engineered to provide the unwavering strength and reliability your systems need.
DAM2-1250 MCCB: Unlock unmatched flexibility and power through our exquisitely designed circuit breakers. Available in three potent ratings of 800, 1000, and 1250 A, each breaker is meticulously crafted to satisfy your most demanding specifications. Choose this excellence to meet and surpass your expectations.
Remark: For specialized applications, our unique 6A version is precisely crafted in the electromagnetic (instantaneous) type. Its distinct characteristics make it ideal for niche uses, ensuring precision for specialized requirements, but not for general use.
Wiring Options: Experience ultimate installation flexibility with our versatile wiring solutions. Choose from front-of-board, back-of-board, or insertion type wiring, allowing for precise customization to meet your installation needs effortlessly.
Over-Current Release Patterns: Our exceptional selection of over-current release types features the thermodynamic-electromagnetic (dual) and electromagnetic (instantaneous) designs. Each pattern is precision-crafted to address varied operational needs, ensuring peak performance.
Outfit Options: Perfect your circuit breaker solution with a host of customizable outfit options. Whether with or without an outfit, this feature empowers you to effortlessly tailor your breaker to meet the unique demands of your applications.
Outfit Details: Elevate your circuit breaker system with a comprehensive array of accessories. Inner options include shunt release, under-voltage release, auxiliary contacts, and alarm contacts. Our advanced outer enhancements integrate a state-of-the-art turning handle and power-driven operation mechanisms, promising seamless integration and flawless function.
Breaking Capacity: Discover the extensive range of breaking capacities with our meticulously engineered choices: L-standard, M-second high, and H-high breaking types. Each is masterfully crafted to suit diverse applications, offering unparalleled precision and reliability.

Dam2 Moulded Case Circuit Breaker for Low Voltage SystemsDam2 Moulded Case Circuit Breaker for Low Voltage Systems


Technical Parameters: Dive deep into the extensive specifications that highlight the superior functionality and performance of our circuit breakers. Uncover the technical brilliance that supports each operation.

1. Instantaneous Action Characteristics: Discover refined precision with distribution circuit breakers featuring a precise setting value of 10In±20%, and the DAM2-1250 model set at 7In±20%. Motor protection circuit breakers enhance security with a steadfast setting value of 12In±20%.
2. Rated Values: For a comprehensive understanding of our circuit breakers' capabilities, consult Table 2 for an in-depth overview of rated values, equipping you with essential specifications at your disposal.
3. Ambient Temperature: At +40ºC, the detailed characteristics of the over-current release action for distribution circuit breakers are outlined in Table 3. For motor protection circuit breakers, refer to Table 4, ensuring optimized performance under varied conditions.

Rated Value: Engage with the intricate specifications of the circuit breaker's rated value. Each aspect is engineered to provide reliable, efficient performance across a diverse range of scenarios, assuring steadfast dependability.

Model Pole Rated current (A) Rated
operating
voltage (V)
Rated
insulation
voltage (V)
Rated ultimate short - circuit breaking capacity (Icu) Flashover
distance(mm)
Test voltage (V) Icu (kA) Ics (kA)
DAM2L-63 3 10,16,20,25,
32,40,50,63
400 500 400×1.10 25 18 0
DAM2M-63 3,4 50 35
DAM2L-100 3,4 16,20,25,32,40,
50,63,80,100
400 800 30 22 ≤50
DAM2M-100 2,3,4 50 35
DAM2H-100 3 85 50
DAM2L-100 3,4 690 10 5
DAM2M-100 2,3,4 20 10
DAM2L-225 3,4 100,125,140,
160,180,200,225
400 800 35 25
TXCM1-225 2,3,4 50 35
DAM2H-225 3 85 50
DAM2L-225 3,4 690 10 5
DAM2M-225 2,3,4 20 10
DAM2L-400 3 225,250,315,
350,400
400 800 50 35 ≤100
DAM2M-400 3,4 65 42
DAM2H-400 3 100 65
DAM2L-400 3 690 15 8
DAM2M-400 3,4 20 10
DAM2L-630 3 400,500,630 400 800 50 35
DAM2M-630 3,4 65 42
DAM2H-630 3 100 65
DAM2L-630 3 6910 15 8
DAM2M-630 3,4 20 10
DAM2M-800 3 630,700,800 400 800 75 50
DAM2H-800 3 100 65
DAM2M-800 3 4690 30 15
DAM2-1250 3 800,1000,1250 400 800 85 42
DAM2-1250 3 690 25 12.5

Note: In 2-pole and 4-pole circuit breakers classified as L, M, and H types, rest assured that the breaking index for each type is equivalent to the M-type, ensuring consistent and uniform performance.

Inverse Time Breaking Action: Delve into the over-current release characteristics for power distribution, assuring steadfast protection when all poles are simultaneously powered, offering trustworthy safeguarding.

No. Test current I/In Set time Initial state
1 Conventional non-tripping current 1.05 2h(In>63A),1h(In≤63A) Cold
2 Conventional non-tripping current 1.30 2h(In>63A),1h(In≤63A) Immediately after Test 1

Instantaneous Action Characteristics: Distribution circuit breakers feature a precise setting value of 10In±20%, while motor protection circuit breakers offer a robust 12In±20%, ensuring dependable and unwavering protection across all scenarios.

Inverse Time Breaking Action: Explore the superior over-current release characteristics, designed meticulously for motor protection. This feature ensures reliable safeguarding with comprehensive power support across all poles, offering steadfast reliability that you can trust.

No. I/In Set time Initial state Remark
1 1.0 >2h Cold  
2 1.2 ≤2h Immediately after Test 1  
3 1.5 ≤4min Cold 10≤n≤225
≤8min 225 < in ≤ 630
4 7.2 4s≤T≤10s Cold 10≤In≤225
6s≤T≤20s 225 < in ≤ 630

Accessories: Immerse yourself in our extensive array of accessories, crafted to significantly enhance the functionality and customization of our circuit breakers. Each piece is expertly designed to elevate performance and adaptability to new heights.

1. Internal Accessories of Circuit Breakers: Discover our sophisticated range of internal enhancements, meticulously engineered to elevate operational excellence and customization, setting a new standard for circuit breaker performance.

1.1 Shunt Release: Experience the perfect blend of innovative design and precision with our shunt release. It is crafted to ensure optimal circuit breaker functionality, offering unparalleled efficiency and reliability.
Shunt Release Voltage: Our shunt release is engineered for unmatched efficiency, boasting a rated control supply voltage of AC50Hz, 230V, 400V, or DC110V, 220V, 24V. It guarantees reliable functionality within a 70%~110% voltage range, ensuring seamless operation.

DC24V Shunt Release: Maintain exceptional reliability by adhering to the specified maximum copper wire length, crucial for ensuring optimal shunt release operation and steadfast performance.

Rated control
supply voltage Uc(DC24V)/Conductor area
1.5mm² 2.5mm²
100%Uc
85%Uc
150m
100m
250m
160m

Design Recommendations: If the table specifications are not met, we advocate for designing the shunt release control circuit as outlined, ensuring maximum effectiveness and operational assurance, providing peace of mind in every application.

1.2 Under-Voltage Release: Experience the epitome of reliability with our under-voltage release, meticulously crafted to deliver consistent and precise performance, enhancing operational safety and efficiency.

Under-Voltage Operation: Enter a realm of unparalleled dependability with our expertly crafted under-voltage release. Designed to maintain impeccable breaker performance amidst supply voltage fluctuations between 70% and 35% of the rated voltage, it ensures steadfast protection and peace of mind.
Under-Voltage Protection: Protect your operations with our state-of-the-art feature, preventing hazardous circuit breaker closures when voltage falls below 35% of the rated threshold. This robust protection ensures secure closure above 85%, offering unwavering safety and performance with each operation.
Closing Mechanism: Our advanced under-voltage release mechanism assures robust circuit breaker closure at supply voltages exceeding 85% of the rated value. This mechanism acts as a formidable shield, ensuring seamless operations and providing an unmatched safety net for your systems.
Under-Voltage Ratings: With ratings at AC50Hz for both 230V and 400V, our circuit breakers deliver uncompromising performance across a wide range of applications, offering peace of mind with every use.
400V.
Special Note: Our circuit breakers, meticulously engineered with under-voltage release, operate flawlessly only at the rated voltage, ensuring secure and dependable opening and closing functions, reinforcing safety in every operation.
normally.

1.3 Pre-Paid Meter Dedicated Release

Pre-Paid Meter Dedicated Release: Rated at AC230/50Hz, this release provides excellent performance over an impressive range of 65% to 110% of Ue. The circuit breaker initiates a precisely timed opening between 0.5 and 2 seconds upon control disengagement, offering unmatched safety and reliability for total peace of mind.

Wiring Diagram for Pre-Paid Meter Dedicated Release

1.4 Rated Values of Auxiliary Contacts and Alarm Contacts (Refer to Table 5)

Classification Conventional thermal current (Ith) Rated current when

 

AC 400V Ie(AC-15)

Rated current when

 

DC 220V Ie(DC-13)

Auxiliary contact 3 0.4 0.15
Alarm contact 3 0.3 0.15

a. Auxiliary Contact

b. Alarm Contact
Our alarm contacts are ingeniously designed to remain inactive during standard operations. They precisely toggle between normal open and closed states only during free or fault tripping events, ensuring accurate and timely alerts when absolutely necessary.

2. External Accessories for Circuit Breakers

2.1 Motor Operating Mechanism: Delve into the comprehensive specifications, including precise rated values and specific codes, all thoroughly detailed in Table 6, providing clarity and confidence in every application.

Category/Model DAM2-63. 125. 250 DAM2-400. 630. 800. 1250
Structure type Electromagnet Motor
AC voltage code AC50Hz,230V,400 AC50Hz,230V,400
DC voltage code DC110V,220V DC110V,220V

NOTE: Following the tripping of the circuit breaker using an electric operating mechanism, it is of utmost importance to perform a reset of the circuit breaker prior to any reclosing attempts. This ensures that operations remain consistently safe and reliable at all times.

Principle Diagram for Opening and Closing of DAM2-63,100,225 Electric Operating Mechanism (AC)

Principle Diagram for Opening and Closing of DAM2-400,630,800,1250 Electric Operating Mechanism (AC)

2.2 Installation Dimensions for Manual Operating Mechanism (Refer to Table 10)
Diagram of Handle Mounting Hole for DAM2-63~800

Total Height of Electric/Manual Operating Mechanism of Circuit Breaker (mm) (Refer to Table 12)

Model Total height of electric
operating mechanism H
Installation dimensions

 

of manual operating mechanism H

DAM2L-63 155 49
DAM2M/H-63 164 49
DAM2L-100 152 51
DAM2M/H-100 170 51
DAM2L-225 182 54
DAM2M/H-225 199 54
DAM2L/M/H-400 255 88
DAM2M/H-630 262 89
DAM2M/H-800 261 96
DAM2H-1250 290 103

Quick Selection Table for DAM2 Series Molded Case Circuit Breakers

Corresponding
letters
Function name Function corresponding to the model
a Model features DAM2 Molded Case

 

Circuit Breaker

b Frame rated current code 63A,100A,225A,

 

400A,630A,800A,

1250A

c Breaking capacity characteristic
code
L-standard breaking type;

 

M-second high breaking type;

H-high breaking type

d Operation mode code No code for handle operation;

 

P for electric operation;

Z for turning handle operation

e Pole 2-two poles;

 

3-three poles;

4-four poles

f Release name 2 Electromagnetic release;

 

3 Double release

g Accessory 00 Without accessory
08 Alarm contact
10 Shunt release
20 Auxiliary contact
30 Undervoltage release
40 Shunt release, Auxiliary contact
50 Shunt release, Undervoltage release
60 Two sets of auxiliary contacts
70 Auxiliary contact, Undervoltage release
18 Shunt release, Alarm contact
28 Auxiliary contact, Alarm contact
38 Undervoltage release, Alarm contact
48 Shunt release, Auxiliary contact, Alarm contact
58 Shunt release, Undervoltage release, Alarm contact
68 Two sets of auxiliary contacts, Alarm contact
78 Auxiliary contact, Undervoltage release, Alarm contact
10Y Pre-paid meter dedicated release
40Y Pre-paid meter dedicated release, Auxiliary contact
50Y Pre-paid meter dedicated release, Auxiliary contact, Undervoltage release
18Y Pre-paid meter dedicated release, Alarm contact
48Y Pre-paid meter dedicated release, Auxiliary contact, Alarm contact
58Y Pre-paid meter dedicated release, Undervoltage release, Alarm contact
h Application No code for distribution;

 

2 for motor protection

i Conventional products No code;

 

T for transparent cover products

j Amperage 10,16,20,25,32,63,80,100,125,160,180,200
,225,250,315,350,400,500,630,700,800,1000
,1250

Example: DAM2L-100 / 33102 63A indicates a DAM2-type molded case circuit breaker, featuring a frame rated current of 100A, with standard breaking capacity, handle operation, 3 poles, dual and shunt release. Designed for motor protection, this model provides a rated current of 63A.
To achieve extraordinary performance, it is imperative that all selection, installation, and usage strictly comply with the product manual or relevant national standards, ensuring optimal operation and safety.
Note: The N-pole type of a 4P circuit breaker is divided into A-type and B-type. In the absence of specific specifications, the standard default is designated as B-type.

Working Principle
The main contact of the molded case circuit breaker is designed for secure fastening either manually or electrically. Upon closure, the advanced free release mechanism firmly locks the main contact, providing a reliable closed position. This robust mechanism ensures consistent performance across various conditions, delivering precise, secure, and dependable protection for your systems.
The current trip coil and the thermal trip element are strategically configured in series with the main circuit. This careful alignment is engineered to deliver superior performance and enduring reliability, shielding your electrical systems from potential disruptions. With this intelligent design, your systems are reinforced with heightened security and operational excellence.
voltage
release
The coil and the power supply are thoughtfully arranged in a parallel configuration. This meticulous design ensures seamless operation, enhancing the efficiency and reliability of your power systems. Experience unmatched performance and consistency, as this arrangement optimizes the delivery of your energy solutions at every level.
Dam2 Moulded Case Circuit Breaker for Low Voltage Systems

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier