DAM1L-125 series Earth Leakage protection circuit breaker(ELCB)
4
P 400V/415V
Earth leakage
circuit breaker high quality
with CE,CB,SEMKO certificate
Introduction
DAM1L
series residual current (leakage) circuit breaker (hereinafter referred to as circuit breaker) is a new series of residual current (leakage) successfully developed by using international standard design and advanced manufacturing technology.
Protected
moulded case
type circuit breaker.
The rated insulation voltage of circuit breakers of this series is 400V (Inm is less than 160A) and 690V (Inm is more than 250A), which is mainly used for ac 50Hz and rated
In a power distribution network with a current of 10A~
5
00A and a rated working voltage of 380V/400V, it is used to distribute electric energy and protect the overload and short circuit of lines and power equipment.
Under normal conditions
,
It can also be used for infrequent switching of lines.
T
his circuit breaker also has the following protection:
·It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection.
·Provide protection against the danger of increasing ground voltage due to insulation damage;
·Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection.
·Circuit breakers with rated current of
5
00A and below can also be used for infrequent start, break off during operation and overload and short circuit protection of squirrel cage motors.
DAM1L
series circuit breakers can be equipped with electric accessories and mechanical accessories for various purposes, such as separately excited tripping device, auxiliary contact, alarm contact and rotating handle operating mechanism.
This series of circuit breakers are widely used in construction, transportation, tunnel, residence, etc.The delay type in this series of circuit breakers is used for branch lines
Distribution of roads;Adjustable type is used to adjust the residual action current or disconnection time on site.
Advantages
°
R
ange:10A to
5
00A(AC)
°integral structure, small volume, high breaking capacity, safe and reliable.
°Adjustable magnetic setting(
0.8
-1times)In.
°Push to trip button provision.
°Separate main and arcing contacts
Innovative and Robust Design
Cutting-Edge Technology
The residual action current or disconnection time can be finely tuned to meet your specific needs.
Exceptional Durability
Superior Performance
Strong anti-interference capability ensures reliable operation.
Wide range of accessories to enhance functionality.
This series of circuit breakers draws working power for the residual current protection circuit from a multi-phase power supply, as opposed to the single-phase power supply used in earlier versions.
Advanced Engineering
Even when the operating power voltage of the residual current protection circuit drops to 50V, the circuit breaker's protection circuit continues to function efficiently (I coherence n=30mA).
This series includes B type (basic breaking capacity, Inm < 100), S type (standard breaking capacity), and H type (high score breaking capacity, Inm > 160), catering to a variety of needs.
High score breaking capacity (Inm > 160) is designed to handle diverse and demanding applications.
Versatile main circuit connection methods include:
-
Piston front connection
-
Terminal extension plate front connection
-
Screw connection at the rear of the piston plate