• Dam2le-400 Earth Leakage Circuit Breaker

Dam2le-400 Earth Leakage Circuit Breaker

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Installation: Fixed
Structure: MCCB
Poles Number: 4
Samples:
US$ 90/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Shanghai, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)

Basic Info.

Model NO.
DAM2LE-400
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
HS Code
85362000
Production Capacity
10000PCS/Month

Product Description

CM1LE Molded Case Circuit Breaker is one of the new breakers which have been designed and developed by the company using international advanced technology. Suitable for the circuits of AC 50Hz, rated voltage of 400V, rated current of 16A to 800A.
Application

DAM2 (CM1) series the rated insulation voltage of the circuit breaker is 800V,it is suitable for the distribution network of AC 50Hz / 60Hz, rated working voltage of 690V and rated current of 1250A, to distribute power and protect circuit and power equipment from being damaged caused by overload , short-circuit, under-voltage and other fault. Also for protection infrequent conversion of the circuits and infrequent start of motor and overload, short circuit, under voltage. DAM2 circuit breaker can be mounted vertically (upright) or horizontally (transverse). DAM2 MCCB is suitable for isolation and the symbol is " ". DAM2 MCCB meets the standard: IEC60947-2 "low-voltage switchgear and control equipment, Part 2: circuit breakers."

Normal operating conditions

1.Ambient air temperature: -5ºC~+40ºC, and average temperature in 24h is below +35ºC.
2.Altitude: The altitude of the installation site is not more than 2000m.
3.Atmospheric conditions: The air relative humidity in the highest temperature +40ºC is not more than 50%; In the low temperature can have higher relative humidity. The maximum average relative humidity is 90%, while the average monthly minimum temperature is +25ºC, and consider the temperature changes in product on the surface of the gel.
4.Pollution Degree: 3.

Selection of instructions

According to the pole, it classifies four types:
Type A: N-pole without over-current release components, and N-pole has been connected all along, and does not act with other three poles to turn on or off;
B-type: N-pole without over-current release components, and N-pole could act with other three poles (N-pole turn-on prior to turn-off);
Type C: N-pole fixed with over-current release components, and N-pole could act with other three poles (N-pole turn-on prior to turn-off);

Classification according to rated current of over-current release:
DAM2-63 MCCB has nine: 6,10,16,20,25,32,40,50,63 A;
DAM2-100 MCCB has nine: 16,20,25,32,40,50,63,80,100 A;
DAM2-250 MCCB has seven: 100,125,140,160,180,200,225 ,250A;
DAM2-400 MCCB has five: 225,250,315,350,400 A;
DAM2-630 MCCB has three: 400,500,630 A;
DAM2-800 MCCB has three: 630,700,800A;
DAM2-1250 MCCB has three: 800,1000,1250A.
Remark: 6A only has electromagnetic (instantaneous) type, is not recommended specifications.
According to the wiring method: wiring in front of board, wiring on back of board, insertion type of the board.
According to over-current release pattern: thermodynamic-electromagnetic (double) type, electromagnetic (instantaneous) type.
According to the outfit, it has two types: with or without outfit.
The outfit include inner accessories and outside accessories: The inner accessories have shunt release, under-voltage release, auxiliary contact and alarm contact. The outside accessories are turning handle operation mechanism, power-driven operation mechanism and so on.
According to the breaking capacity: L-standard breaking type; M-second high breaking type; H-high breaking type

Technical parameters

1, Instantaneous action characteristic setting value of the circuit breaker for distribution is 10In±20%, DAM2-1250 is 7In±20%; Instantaneous action characteristic set value of the circuit breaker for motor protection is 12In ± 20%.
2, The rated value of the circuit breaker in Table 2.
3, In the ambient temperature of +40ºC, the circuit breaker for distribution over-current release action characteristics shown in Table 3, the circuit breaker for motor protection over-current release action characteristics shown in Table 4.

Rated value of the circuit break

Application

Its main function is to provide indirect contact protection for personal electric shock of fatal danger. Rated residual operating current does not exceed residual current operated circuit breaker of 0.03A when other protection measures are invalid, also can provide supplementary protection for direct contact, but not as the only direct contact protection. At the same time, CM1LE MCCB ELCB can also prevent electrical fire caused by the contact fault current. And CM1LE MCCB ELCB can protect overload and short circuit of the circuits, can also be used for infrequent conversion of the circuits.
The CM1LE MCCB ELCB has the small volume (equal to the volume of the corresponding molded case circuit breaker), high breaking, short arc arcing and residual operating current. At the same time, CM1LE MCCB ELCB can take alarm contact, shunt release, undervoltage release, auxiliary contact, turning handle operating mechanism, electric operation mechanism and other accessories. The wiring method has many ways: wiring in front of board, wiring on back of board, insertion type of the board and so on, is ideal product for users.
DAM2 CM1LE MCCB (CM1LE MCCB switch) can be mounted vertically (upright) or horizontally (transverse).
The Circuit breaker Meet the standards:  IEC 60947-20

According to the pole, it classifies four types:
Type A: N-pole without over-current release components, and N-pole has been connected all along, and does not act with other three poles to turn on or off;
B-type: N-pole without over-current release components, and N-pole could act with other three poles (N-pole turn-on prior to turn-off);
Type C: N-pole fixed with over-current release components, and N-pole could act with other three poles (N-pole turn-on prior to turn-off);
D-type: N-pole fixed with over-current release components, and N-pole has been connected all along, and does not act with other three poles to turn on or off.

Note: The code with Y in parentheses means the shunt release with delay function. The delay time is 0.5s ~ 2s, control voltage is AC240V / AC400V.
Only 4-poles products of B-type and C-type have 240,250,218,248 and 340,350,318,348 specifications annex code.
Only TXM1L-400 and 800-frame 4-pole products of B-type and C-type have 260,270,268 and 360,370,368 specifications annex code.

Classification of circuit breakers

According to the poles of products: two poles, three poles and four poles.
The two-poles product is only available in CM1LE-100M / 2300, CM1LE-225L / 2300, CM1LE-225M / 2300.
According to the wiring method: wiring in front of board, wiring on back of board, insertion type of the board;
According to the application: for distribution and for motor protection;
According to over-current release pattern: thermodynamic-electromagnetic (double) type, electromagnetic (instantaneous) type;
According to the residual current breaking time: non time-delay and time-delay;
According to the rated ultimate short-circuit breaking capacity of the circuit breaker: L-standard breaking type; M-second high breaking type; H-high breaking type;
According to the operation mode: the handle direct operation, the motor operation (with P), turning handle operation (for switchgear, with Z).

Normal operating conditions and installation conditions

Ambient air temperature
The upper limit of ambient air temperature is +40ºC;
The lower limit of ambient air temperature is -5ºC;
The average value of ambient air temperature within 24h does not exceed +35ºC.
Altitude: The altitude of the installation site is not more than 2000m.
Pollution degree: 3.
Installation category: .
Atmospheric conditions: The air relative humidity in the highest temperature + 40ºC for not more than 50%; In the low temperature can have higher relative humidity. The maximum average relative humidity is 90%, while the average monthly minimum temperature is +20ºC, and consider the temperature changes in product on the surface of the gel.
External magnetic field: The external magnetic field in the vicinity of the installation site does not exceed 5 times the geomagnetic field in any direction.

Technical parameters

 

Circuit breaker(IEC60947-2/GB14048-2)
Frame current Inm 100 225 400 800
Whether it is suitable for motor protection        
Rated insulation voltage(V) AC800V AC800V AC800V AC800V
Rated impulse withstand voltage(KV) 8 8 8 8
Rated operating voltage AC AC400V AC400V AC400V AC400V
Breaking capacity level L M L M L L
Pole 3,4 3,4 3,4 3,4 3,4 3,4
Ultimate breaking capacity AC400V 35 50 35 50 50 50
Operation breaking capacity AC400V 22 30 22 30 30 30
Rated residual short-circuit making (breaking) capacity I△m KA 25%Icu 25%Icu 25%Icu 25%Icu 25%Icu
Default rated residual operating current I△nt mA 30/100/300 100/300/500 100/300/500 300/500/100
Rated residual non-operating current I△noh mA 1/2I△n 1/2I△n 1/2I△n 1/2I△n
General breaking time S 0.2
Delay breaking time S 0.3,0.4,0.5,0.6,1.0,2.0
Optional rated residual current I△nt mA 30-100-300mA ,100-300-500mA,300-500-1000mA,50mA,75mA,300mA
Mechanical life 8500 7000 4000 2500
Electrical life 1500 1000 1000 500
Flashover distance 50mm 50mm 100mm 100mm
Release / Rated current
Thermal magnetic fixed / Rated current 40/50/63/80/100 100/125/160/180/200/225 200/225/250/315/350/400 400/500/630
Accessory
Shunt        
Undervoltage        
Auxiliary        
Alarm        
Leakage alarm module Leakage alarm action        
Leakage alarm non-action        
Turning handle operating mechanism        
Electric operating mechanism        
Installation and connection
Fixed on back of the board        
Fixed on back of the board        
Inset on back of the board        
Product certification CCC,CE

Note: There are 4 types of 4P
Type A: N pole is not installed over-current trip components, and N-pole is always connected, not together with the other three points together;
B-type: N pole is not installed over-current trip components, and N-pole together with the other three points together (N first after the first sub-points);
Type C: N pole is equipped with overcurrent trip element, and N pole is combined with other three poles.
D-type: N pole installed over-current trip components, and N-pole is always connected, not with the other three-pole together points.

Characteristics of inverse time breaking action of circuit breakers over-current release for power distribution when every pole is power-on at the same time (see Table 3)

No. Test current I/In Set time Initial state
1 Conventional non-tripping current 1.05 2h(In>63A),1h(In≤63A) Cold
2 Conventional tripping current 1.30 2h(In>63A),1h(In≤63A) Immediately after Test 1

Characteristics of inverse time breaking action of over-current release for motor protection when every pole is power-on at the same time (products of 16A~40A without motor protection)

No. Setting current Set time
Inm=125A Inm=250A,400A Inm=630A,800A Initial state
1 1.0In >2h >2h >2h Cold
2 1.2In ≤2h ≤2h ≤2h Immediately after Test 1
3 1.5In ≤4min ≤4min ≤8min Hot
4 7.2In 4s<t≤10s< td=""> 4s<t≤10s< td=""> 6s<t≤20s< td=""> Cold

Residual current breaking time of the residual current operated circuit breaker

Action characteristics of general residual current operated circuit-breakers of I△n ≤ 30mA should be non time-delay type.

Note: a. For circuit breaker of I△n≤30mA, 5I△n can be replaced with 0.25A. b. Using 0.25A by Note a., then 10I△n is 0.5A.

Residual current I△n 2I△n 5I△na 10I△nb
Max breaking time(s) 0.2 0.15 0.04 0.04

Action characteristic of time delay residual current operated circuit breaker

Limit non-driving time of time delay circuit breaker according to regulations of 2I△n, its action characteristic.

Delay time(S) Max breakingtime when I△n (s) Limit non-drivingtimewhen 2I△n (s) Max breakingtime((s) Max breaking timewhen 5I△n (s) Max breaking timewhen 10I△n (s)
0.3 0.3 0.1 0.3 0.25 0.25
0.4 0.4 0.2 0.4 0.35 0.35
0.5 0.5 0.3 0.5 0.45 0.45

Instantaneous action characteristic setting value of the residual current operated circuit breaker for distribution is 10In±20%, and instantaneous action characteristic setting value of the residual current operated circuit breaker for motor protection is 12In±20%.

Inverse time protection characteristic curve of residual current operated circuit breaker

 

Structure and working principle

CM1LE series residual current operated circuit breakers are electronic residual current operated circuit breakers, mainly consists of the zero-sequence transformer, Electronic control leakage release and circuit breakers with overload and short circuit protection, all components are installed in a pair of plastic case.
When the circuits protected by the chip processing have leakage or personal electric shock, as long as the residual current reach to setting operating current value, the output signal of the secondary winding of the zero-sequence transformer trigger SCR to conduct, and make residual current operated circuit breaker act by the leakage release, thereby cutting off the power supply to play the protective role in leakage and electric shock.

 

When the protected circuits have overload or short circuit, the thermal magnetic release complete the delay or instantaneous trip action to make the residual current operated circuit breaker act, thereby cutting off the power supply to play the protective role in overload and shout-circuit.

Inner accessory of earth leakage circuit breakers

a. Undervoltage release

When the voltage drops (or even slow down) to the rated voltage range of 70% and 35%, undervoltage release should act; undervoltage release should prevent residual current operated circuit breaker closing when the power supply voltage is below the release voltage of 35%; When the supply voltage is equal to or greater than 85%, undervoltage release should ensure that the residual current operated circuit breaker can be closed. The rated value and code are shown in Table 7.
Note: Residual current operated circuit breakers equipped with undervoltage releases can be normally closing and opening when the undervoltage release at the rated voltage.

Code A2 A4
Voltage specification AC230V AC400V
Rated frequency 50Hz 50Hz

b. Shunt release

Residual current operated circuit breakers can be reliably disconnected at rated voltage of 70% to 110%. Rating and code (see Table 8)

Code A2 A3 D1 D2 D3
Voltage specification AC230V AC400V DC110V DC230V DC240V
Rated frequency 50Hz 50Hz -- -- --

Note: When the voltage specification is DC24V, the rated current is 5A ± 0.5A.

 

C. Auxiliary contact and alarm contact parameters

Frame grade Conventional heating current Ith A Rated current in AC400V Ie A Rated current in AC230V Ie A
Inm≤250A 3 0.3 0.15
Inm≥400A 3 0.4 0.2

Auxiliary contact

 

Alarm contact
When residual current operated circuit breaker opens and closes normally, the alarm contact does not act, only after the free trip (or fault trip), alarm contact alarms, the contact changes the original position, is that normally open transfers closed, normally closed transfers open. When the circuit breaker buckles again, the alarm contact restore the original state.

 

External accessories of earth leakage circuit breakers

Electric operating mechanism
When control voltage is in rated control voltage range of 85%-110%, the residual current operated circuit breaker can be making and breaking reliably. The rated value of the motor operated mechanism (see Table 10), the total height of the residual current operated circuit-breaker mounted with electric operating mechanism (see Table 11).

Product Model Rated control voltage(V) Mechanical life(times) Operating current(A) Power consumption(W)
CM1LE-100L/M AC400V,AC230V 10000 ≤5 14
CM1LE-225L/M 8000
CM1LE-400M/H 5000 ≤5.7 120
CM1LE-630M/H 5000 ≤2 35
CM1LE-800M/H 3000 ≤2 35
Model CM1LE-100L/M CM1LE-225L/M CM1LE-400M/H CM1LE-630M/H
CM1LE-800M/H
Height H(mm) 164 170 238 261

Installation dimensions of handle operating mechanism

 

Model 125L/M 225L/M 400M/H 630M/H 800M/H
Installationdimensions(mm)H 54 56 88 63 63
Y value of theoperating handle relative

 

to the center of the

circuit breaker

0 0 0 0 0

Wiring diagram of leakage alarm module

 

Precautions:
1, Leakage alarm module auxiliary contact capacity: AC230V 0.5A.
2, The product must be connected to the module power supply before closing.
3, After leakage alarm, no pressing product test button continuously.
4, After leakage alarm, please promptly remove the fault, and press the reset button to reset.

Selection principle:
When selecting the rated residual operating current value of the residual current operated circuit breaker, the possible normal leakage current value of the protected circuit or equipment should be taken into account. When necessary, the leakage current value of the protected circuit or equipment can be got by actual measurement.
Selecting of the rated residual non-operating current of residual current operated circuit breakers, which should be not less than 2 times the maximum value of the normal leakage current of the electrical wiring and equipment.
Residual current operated circuit-breakers with a rated residual operating current of 30 mA should be preferred when hand-held power tools, portable electrical appliances, household appliances, sockets, appliances for construction sites (rated current not less than 100 A) and other equipments have difficulty in ground connection.
The residual current operated circuit-breaker with a rated residual operating current of 30 mA can be selected for single device. The residual current operated circuit-breaker with a rated residual operating current of 30 mA or more can be selected for the total protection of multiple devices (multi-branch).
Residual current operated circuit-breakers with a rated residual operating current of 30 mA should be selected for electrical equipment installed in wet locations.

Outline dimensions

Dimension of wiring in front of the board of CM1LE-125,250,400,630,800

 

Model Pole Installation dimensions mm
a b d e Mounting hole
CM1LE-100L
CM1LE-100M
2 - 132 - - 2XΦ5
3 30 132 - - 4XΦ5
4 60 132 - - 6XΦ5
CM1LE-225L
CM1LE-225M
2 - 126 - - 2XΦ5
3 35 126 - - 4XΦ5
4 70 126 - - 6XΦ5
CM1LE-400M
CM1LE-400H
3 44 194 331 105 4XΦ7
4 94 194 331 153 6XΦ7
CM1LE-630M
CM1LE-630H
3 70 243 387 140 4XΦ8
4 140 243 387 210 6XΦ8
CM1LE-800M
CM1LE-800H
3 70 243 387 140 4XΦ8
4 140 243 387 210 6XΦ8
Model Pole Outline dimensionmm (max)
A B C D E F G H L
CM1LE-100L
CM1LE-100M
2 63 155.5 73.54 96 51 23 - - 256
3 90.5 155.5 73.5 96 51 23 - - 256
4 120.5 155.5 73.5 96 51 23 - - 256
CM1LE-225L
CM1LE-225
2 79 166 73.5 96 63 23 - - 370
3 105 166 73.5 96 63 23 - - 370
4 140.5 166 73.5 96 63 23 - - 370
CM1LE-400M
CM1LE-125H
3 150 257 110 162 89 66 28 46 462
4 200 257 110 162 89 66 28 46 462
CM1LE-630M
CM1LE-630H
3 210 280 118 170 81 66 44 54 490
4 280 280 118 170 81 66 44 51 490
CM1LE-800M
CM1LE-800H
3 210 280 118 170 81 66 44 51 490
4 280 280 118 170 81 66 44 51 490

Plug-in wiring diagram

 

Aperture diagram of plug-in wiring

 

Wiring on back of the board of CM1LE-100, 225

 

Wiring on back of the board of CM1LE-400, 630, 800

 

Aperture diagram of wiring o back of the board

 

  Model
125L/M 250L/M 400M/H 630M/H 800M/H
Outlinedimension W1 30 35 48 70 70
H6 - - 18 20 20
H7 63 88 39 64 64
H8 96 126 74 64 64
H9 39 47 60 87 87
H10 62 79 88 143.7 143.7
H11 122 134 111 158.7 158.7
H12 13 13 21.5 27 27
M 8 8 - - -
Φd1 - - Φ12 Φ16 Φ16
M1 - M8 M10 M12 M12
Installationdimensions Φd2 6 6 9 12 12
ΦD - - 33 37 37
L2 136 144 224 243 243
L4 104 104 163 173 173
L5 168 184 285 305 305
L6 3P:95
4P:125
3P:110
4P:145
3P:150
4P:198
3P:215
4P:285
3P:215
4P:285
K 90 105 60 210 90
K1 - - 66 95 95
K2 M8* 6 8 16 16
K3 M8* 25 28 44 44
J 72 73 130.4 146 146
A - - 44 70 70
Φd - - 7 7 7

Note: Specifications of "*" in the table is the screw-type plug-in of wiring on back of the board.

How to fast selection of CBR Earth leakage circuit breaker CM1LE

 

Corresponding letters Function name Function correspondingto the model
a Model features CM1LE earth leakagecircuit breaker
b Frame ratedcurrent code 100A,225A,400A,630A,800A
c Breaking capacitycharacteristic code L-standard breaking type;M-second high breaking type;

 

H-high breaking type

d Operation mode code No code for handle operation;P for electric operation;

 

Z for turning handle operation

e Pole 2-two poles;3-three poles;

 

4-four poles

f Release name 2 Electromagnetic release;3 Thermal magnetic release
g Accessory 00 No accessory
08 Alarm contact
10 Shunt release
20 Auxiliary contact
28 Auxiliary contact, Alarm contact
30 Undervoltage release
40 Shunt release, Auxiliary contact
48 Shunt release, Auxiliary contact, Alarm contact
60 Two sets of auxiliary contacts
68 Two sets of auxiliary contacts, Alarm contact
70 Auxiliary contact, Undervoltage release
h Application No code for distribution;2 for motor protection
i Conventional products No code;T for transparent cover products
j Rated current 16,20,25,32,63,80,100,125,160,180,200,22
5,250,315,350,400,500,630,700,800
k Rated residualoperating current
(mA)
Normal type:30,50,100,200,300,500
Adjust type: 30,50,100; 50,100,200;50,200,300; 100,200,300;

 

100,300,500; 200,300,500; 300,500

Other instructions Breaking time Normal type code: 0.1,0.2;Delay type code: 0.3,0.4,0.5
Rated voltage of motoroperating mechanism AC230V / AC400V / DC23
Rated voltageof shunt release Ac230 / AC400V / DC230V / DC400V
Undervoltage release AC230V / AC400V

Example: CM1LE-225M / 4310 150A 50mA 0.4s AC230V, means CM1LE-225 type residual current operated circuit breaker for distribution protection, frame rated current of 225A, rated current of 150A, the second high type breaking capacity, four-poles, rated residual operating current of 50mA, delay type, breaking time <0.4s, thermal magnetic release, with shunt release (AC230V).
Selection, installation, use should be consistent with the product manual or the relevant national standards.

Structure chart of classification protection coordination of Earth Leakage Circuit Breaker

Rated current of 400A of the first level protection residual current operated circuit breaker, for example:

 

First level protection

Connecting wires:
Copper core plastic insulated conductor cross-sectional area is 50mm ²
Rated operating current: 250A
Rated residual operating current: 300mA ~ 500mA
Residual breaking time: 0.6s ≤ t ≤ 0.8s
The optional residual current operated circuit-breakers are:
CM1LE-225/400, DZ20L-250/400

Second level protection:

Connecting wires:
Copper core plastic insulated wire cross-sectional area is 4 ~ 16mm ²
Rated operating current: 100A, 80A, 63A, 40A
Rated residual operating current: 100mA ~ 300mA
Residual breaking time: 0.2s ≤ t ≤ 0.4s
The optional residual current operated circuit breakers are:
CM1LE-100/225, DZ20L-160, DZ15LE-100

Third level protection:

Connecting wires:
Copper core plastic insulated conductor cross-sectional area is 1.5 ~ 4mm ²
Rated operating current: 40A, 32A, 20A
Rated residual operating current: 30mA or less
Residual breaking time: t ≤ 0.1s or faster
The optional residual current operated circuit-breakers are:
CM1LE-100, DZ47LE-63

Fourth level protection:

Connecting wires:
Copper core plastic insulated conductor cross-sectional area is 1 ~ 2.5mm ²
Rated operating current: 32A, 20A
Rated residual operating current: 10mA or less
Residual breaking time: fast action type
The optional residual current operated circuit breakers are:
DZ47LE-63, DZ30LE-32

Ordering information

Users must specify when ordering:

7.1 Type and name of residual current operated circuit-breakers;
7.2 Rated current of residual current operated circuit breaker over-current release;
7.3 Rated residual operating current of residual current operated circuit breaker;
7.4 Breaking time of residual current operated circuit breaker;
7.5 Protection category, poles and quantity;
7.6 The rated voltage of the internal accessories and external accessories of the residual current action circuit breaker.
Note: When ordering, please specify the protection type of N-pole, in the absence of the protection type, the products are provided of S-type are A (3N) type, H-type are B type.

Example 1: Order CM1LE-1255/3328 40A 50mA <0.1s 80 units. This indicate that you order CM1LE-125/3328 residual current operated circuit breakers, rated current of over-current release is 40A, rated residual operating current is 50mA, breaking time <0.1s, three-poles, with auxiliary contacts and alarm contacts, for power distribution, 80 units.
Example 2: Order CM1LE-125H / 43102B 100A 30/50/100mA <0.1 s AC230V AC 230V 50 units. This indicate that you order CM1LE-125H/43102B residual current operated circuit breakers, rated current of over-current release is 100A, rated residual operating current is 30/50/100 mA (three-kinds adjustable), the breaking time <0.1s, second high type breaking capacity, four-poles, for motor protection, with electric operating mechanism (AC230V), shunt release (AC230V), N-pole protection type is B-type, 50 units.

           
     
                 
       
               
       
       
         
       
             
       
       
         
       
               
       
       
         
       
             
       
       
         
       
             
       
         
             
         

Note: 2-poles, 4-poles circuit breakers, divided into L, M, H, they have the same breaking index as M-type.

Characteristics of inverse time breaking action of circuit breakers over-current release for power distribution when every pole is power-on at the same time

No. Test current I/In Set time Initial state
1 Conventional non-tripping current 1.05 2h(In>63A),1h(In≤63A) Cold
2 Conventional non-tripping current 1.30 2h(In>63A),1h(In≤63A) Immediately after Test 1

Instantaneous action characteristic setting value of the circuit breaker for distribution is 10In±20%, and instantaneous action characteristic setting value of the circuit breaker for motor protection is 12In±20%.

Characteristics of inverse time breaking action of circuit breakers over-current release for motor protection when every pole is power-on at the same time

No. I/In Set time Initial state Remark
1 1.0 >2h Cold  
2 1.2 ≤2h Immediately after Test 1  
3 1.5 ≤4min Cold 10≤n≤225
≤8min 225 < in ≤ 630
4 7.2 4s≤T≤10s Cold 10≤In≤225
6s≤T≤20s 225 < in ≤ 630

Accessories

1,Internal accessory of circuit breakers

1.1 Shunt release
Rated control supply voltage of the shunt release: AC50Hz, 230V, 400; DC110V, 220V, 24V; When between 70%~110%, can break the circuit breaker reliably.<

When rated control supply voltage of the shunt release is DC24V, the maximum length of copper wire should meet the following requirements

Rated control
supply voltage Uc(DC24V)/Conductor area
1.5mm² 2.5mm²
100%Uc
85%Uc
150m
100m
250m
160m

If the requirements of the above table are not met, it is recommended to design the shunt release control circuit using the following figure

1.2 Under-voltage release

When the power supply voltage drops to under-voltage release rated voltage of 70% to 35% of the range, the under-voltage
release circuit breaker reliable break; when the supply voltage is below the rated voltage undervoltage release 35% , Under-voltage
release to prevent the circuit breaker is closed; when the supply voltage is higher than 85% of the rated voltage of the under-voltage
release, the under-voltage release ensures that the circuit breaker is closed. The undervoltage releases are rated at AC50Hz, 230V,
400V.
Special Note: The circuit breaker with undervoltage release, only in the under-voltage with rated voltage, which can open and close
normally.

1.3 Pre-paid meter dedicated release

The rated operating voltage Ue of the pre-paid meter dedicated release is AC230/50Hz, it can worknormally in the range of (65% ~ 110%) Ue. When the Ctrl is cut off, the circuit breaker will delay 0.5s ~ 2s to be opening.

Wiring diagram of pre-paid meter dedicated release 

1.4 The rated value of auxiliary contacts and alarm contacts in Table 5

Classification Conventional thermal current (Ith) Rated current when

 

AC 400V Ie(AC-15)

Rated current when

 

DC 220V Ie(DC-13)

Auxiliary contact 3 0.4 0.15
Alarm contact 3 0.3 0.15

a. Auxiliary contact

b. Alarm contact
Alarm contacts don't act when the circuit breaker opens and closes normally, alarm contacts switch between normal opening and normal closing only after free tripping or fault tripping.

 

2,External Accessory for Circuit Breakers

2.1 Motor operating mechanism. The rated value and code are shown in Table 6.

Category/Model DAM2-63. 125. 250 DAM2-400. 630. 800. 1250
Structure type Electromagnet Motor
AC voltage code AC50Hz,230V,400 AC50Hz,230V,400
DC voltage code DC110V,220V DC110V,220V

NOTE: After the tripping of circuit-breaker with electric operating mechanism, the electric operating mechanism must make the circuit-breaker buckle again, then it can close.

The principle diagram of the opening and closing of DAM2-63,100,225 electric operating mechanism(AC)

The principle diagram of the opening and closing of DAM2-400,630,800,1250 electric operating mechanism(AC)

2.2 Installation dimensions of manual operating mechanism shown in Table 10
Diagram of handle mounting hole of DAM2-63~800

Total height of electric/manual operating mechanism of circuit breaker (mm)(shown in Table 12)

Model Total height of electric
operating mechanism H
Installation dimensions

 

of manual operating mechanism H

DAM2L-63 155 49
DAM2M/H-63 164 49
DAM2L-100 152 51
DAM2M/H-100 170 51
DAM2L-225 182 54
DAM2M/H-225 199 54
DAM2L/M/H-400 255 88
DAM2M/H-630 262 89
DAM2M/H-800 261 96
DAM2H-1250 290 103

How to fast Selection Table of DAM2 Series Molded Case Circuit Breaker

Corresponding
letters
Function name Function corresponding to the model
a Model features DAM2 Molded Case

 

Circuit Breaker

b Frame rated current code 63A,100A,225A,

 

400A,630A,800A,

1250A

c Breaking capacity characteristic
code
L-standard breaking type;

 

M-second high breaking type;

H-high breaking type

d Operation mode code No code for handle operation;

 

P for electric operation;

Z for turning handle operation

e Pole 2-two poles;

 

3-three poles;

4-four poles

f Release name 2 Electromagnetic release;

 

3 Double release

g Accessory 00 Without accessory
08 Alarm contact
10 Shunt release
20 Auxiliary contact
30 Undervoltage release
40 Shunt release, Auxiliary contact
50 Shunt release, Undervoltage release
60 Two sets of auxiliary contacts
70 Auxiliary contact, Undervoltage release
18 Shunt release, Alarm contact
28 Auxiliary contact, Alarm contact
38 Undervoltage release, Alarm contact
48 Shunt release, Auxiliary contact, Alarm contact
58 Shunt release, Undervoltage release, Alarm contact
68 Two sets of auxiliary contacts, Alarm contact
78 Auxiliary contact, Undervoltage release, Alarm contact
10Y Pre-paid meter dedicated release
40Y Pre-paid meter dedicated release, Auxiliary contact
50Y Pre-paid meter dedicated release, Auxiliary contact, Undervoltage release
18Y Pre-paid meter dedicated release, Alarm contact
48Y Pre-paid meter dedicated release, Auxiliary contact, Alarm contact
58Y Pre-paid meter dedicated release, Undervoltage release, Alarm contact
h Application No code for distribution;

 

2 for motor protection

i Conventional products No code;

 

T for transparent cover products

j Amperage 10,16,20,25,32,63,80,100,125,160,180,200
,225,250,315,350,400,500,630,700,800,1000
,1250

Example: DAM2L-100 / 33102 63A means DAM2-type molded case circuit breaker, frame rated current is 100A, breaking capacity is the standard type, handle operation, 3 poles, double release, with shuntrelease, for motor protection, rated current is 63A.
Selection, installation, use should be consistent with the product manual or the relevant national standards.
Note: N-pole type of 4P circuit breaker is divided into A-type, B-type, which is not specified defaults to B type.



Working principle
The main contact of the molded case circuit breaker is manual manipulation or electric closing. After the main contact is closed, the free release mechanism locks the main contact into the closing position. The over current trip coil and the thermal trip element are connected in series with the main circuit. The under voltage release coil and the power supply are connected in parallel.

Dam2le-400 Earth Leakage Circuit Breaker
 