800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 415/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • 800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB
  • 800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB
  • 800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB
Find Similar Products

Basic Info.

Model NO.
DAM1-1600
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
ISO9001-2000, CE, CB, CCC, Asta,Semko,RoHS
Base
BMC Unflaming Material
Thermal Adjustable
Min:0.4-Max:1in
Magnetic Adjustable
Min:1.5-Max:12in
Rated Insulation Voltage
1000V
Rated Operation Voltage
400V
Outline Dimension
406X210X138.5mm
Transport Package
Carton
Specification
800, 1000, 1250, 1600A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
8536200000
Production Capacity
1000PCS/Month

Product Description

Introduction

Circuit Breakers with Electronic Over Current Release:
The feature discriminating electronic circuit breakers from thermal-magnetic
breakers is to control the over current releases with electronic is circuit. Electronic is
control is performed via microprocessor.During design of the electronic circuit,
worst possibilities to encounter in operation have been taken into consideration. In high circuit currents, direct opening has been ensured without operating electronic circuit. In this way, possibility of failure in the electronic circuit has been eliminated.
-Maximum, minimum, average etc. Values of the drawn current at various time intervals (day-night) can be taken.Rated and Instant opening current adjustment areas of electronic circuit breakers are quite wide. This feature allows wide use opportunity to the breaker Furthermore, electronic circuit breakers are not affected from ambient temperatures.

Advantages


°Wide range:800A to 1600A(AC)
°Compact dimensions
°Adjustable thermal setting(40-100%)In.
°Adjustable magnetic setting(1.5-12times)In.
°Push to trip button provision.
°Separate main and arcing contacts
°Wide range of accessories.
 
Electronic Circuit Breakers   
Model DAM1-1600
Breaking Capacity Code S H G
Rated Current of Frame size- Inm                                                                    (A) 1600A
Rated Current-In(40,50 or 55ºC)                                                                      (A) 800 -1000 - 1250 - 1600A
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz                                                    (V) 750V
Rated operation Voltage  -Ue(a.c.) 50-60Hz                                                    (V) 400V
Number of Pole 3P
Rated ultimate short Circuit breaking Capacity  kA  Icu AC400V/50Hz O-CO          (KA) 65 85 100
Rated service short Circuit breaking Capacity  kA  Ics AC400V/50Hz O-CO-CO     (KA) 50 50 50
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO         (KA) 105/0.25 143/0.2 220/0.2
Rated impulse withstand Voltage -Uimp                                                                            (V) 8000
Dielectric Propery (V) 3000
lonization distance                                                                                                              (mm) 80/0
Endurance Total Cycles 3000
Electrical Life 500
Mechanical Life 2500
Over Current trip Thermal release adjustable    (0,4-0,5-0,6-0,7-0,8-0,9-1)x1In
Magnetic release adjustable    (1,5-2-4-6-8-10-12)xIn
Operating Curve at 6Ir 3S-6S-12S-18S
Category (EN 60947-2/IEC 60947-2) Main circuit A/B
Auxiliary circuit AC-15
Under Voltage Release 
Shunt Release
Auxiliary Contact
Alarm Contact
Auxiliary Contact and Alarm Contact
Handle Operation Mechanism
Electrical Operastion Mechanism 
DIN clips -
Terminal cover    
Phase seperator    
Extention Handle    
  W (mm) 3P 210
4P -
L (mm) 3P 406
4P -
H (mm) 3P 138.5
4P -
Weight Fixed version 3P/4P 17.2/22.2
Plug-in version 3P/4P -
Draw out version 3P/4P 22/30.1

Electrical parameters of DAM1 MCCB adjustable type molded case circuit breaker
Table1 PR211 type
S.No. Function Settings Type PR211 PR211 PR211 PR211 Factroy reset
Poles 3P 3P 3P 3P
Rating (A) 250 400 800 1600
1 L Overload Current Setting (A) (0.4,0.5,0.6,0.7,0.8,0.9,0.95,1.0)xIn (0.4,0.5,0.6,0.7,0.8,0.9,0.95,1.0)xIn (0.4,0.5,0.6,0.7,0.8,0.9,0.95,1.0)xIn (0.4,0.5,0.6,0.7,0.8,0.9,0.95,1.0)xIn 1.0In
2 Time Delay at Overload Current Setting 3S,6S,12S,18S 3S,6S,12S,18S 3S,6S,12S,18S 3S,6S,12S,18S 3S
3 I Instantaneous Current Setting (1.5, 2, 4, 6, 8, 10, 12,OFF)xIn (1.5, 2, 4, 6, 8, 10, 12,OFF)xIn (1.5, 2, 4, 6, 8, 10, 12,OFF)xIn (1.5, 2, 4, 6, 8, 10, 12,OFF)xIn 10In
Table2 PR212 type
S.No. Function Settings Type PR212 PR212 PR212 PR212 Factroy reset
Poles 3P 3P 3P 3P
Rating (A) 250 400/630 800 1600
1 L Overload Current Setting (A) (0.4,0.5,0.55,0.6,0.65,0.7,0.75,0.8)xIn (0.4,0.5,0.55,0.6,0.65,0.7,0.75,0.8)xIn (0.4,0.5,0.55,0.6,0.65,0.7,0.75,0.8)xIn (0.4,0.5,0.55,0.6,0.65,0.7,0.75,0.8)xIn 1.0In
2 Time Delay at Overload Current Setting 3S,6S,12S,18S 3S,6S,12S,18S 3S,6S,12S,18S 3S,6S,12S,18S 3S
3 S Short - Circuit Current Setting (A) (1, 2, 3, 4, 6, 8, 10,OFF)xIn (1, 2, 3, 4, 6, 8, 10,OFF)xIn (1, 2, 3, 4, 6, 8, 10,OFF)xIn (1, 2, 3, 4, 6, 8, 10,OFF)xIn 6In
4 Time Delay at Short Circuit Current Setting 0.05,  0.1, 0.25, 0.5 0.05,  0.1, 0.25, 0.5 0.05,  0.1, 0.25, 0.5 0.05,  0.1, 0.25, 0.5 0.1S
5 I Instantaneous Current Setting (1.5, 2, 4, 6, 8, 10, 12,OFF)xIn (1.5, 2, 4, 6, 8, 10, 12,OFF)xIn (1.5, 2, 4, 6, 8, 10, 12,OFF)xIn (1.5, 2, 4, 6, 8, 10, 12,OFF)xIn 10In
6 G Ground Fault Current Setting (A) (0.2,0.3,0.4, 0.6,0.8,0.9,1.0, OFF)xIn (0.2,0.3,0.4, 0.6,0.8,0.9,1.0, OFF)xIn (0.2,0.3,0.4, 0.6,0.8,0.9,1.0, OFF)xIn (0.2,0.3,0.4, 0.6,0.8,0.9,1.0, OFF)xIn 1.0In
7 Time Delay at Ground Fault Setting 0.1, 0.2, 0.4, 0.8 0.1, 0.2, 0.4, 0.8 0.1, 0.2, 0.4, 0.8 0.1, 0.2, 0.4, 0.8 0.4S
8   Selection of electric or electronic parameters set Function SET (switch ELT/MAN)
9   Used for setting parameters of dip switch of zero line InN=%In,switch 50/100
10   Socket for connection measuring device Panel socket



800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB
800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB
800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB
800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB
800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB
800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB
800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB
800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB
800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB
800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB
800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB

800, 1000, 1250, 1600A Thermal Overload Protection Pr212 MCCB with CB

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier