RCBO with Residual Leakage Current Protection 3p Circuit Breaker

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: Arc Chamber
Installation: Fixed
Structure: MCB
Samples:
US$ 4/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Shanghai, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)

Basic Info.

Model NO.
DABL-63
Poles Number
1p+N
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CB, CCC
Release Type
Electronic Type
Rated Residual Current Motion
10mA, 30mA, 100mA, 300mA
Residual Leakage Current Curve
a, AC, S Type
Transport Package
Carton
Specification
6, 10, 16, 20, 25, 32, 40, 50, 63A
Trademark
CDADA, OEM, ODM
Origin
Shanghai
HS Code
85362000
Production Capacity
200000PCS/Month

Product Description

DABL-63 6kA 10kA Electronic Residual Current Device RCBO Circuit Breaker

Introduction
The DABL-63 6kA 10kA electronic residual current circuit breaker, masterfully engineered by DaDa's dedicated team, guarantees stable operation, accurate protection, rapid opening times, and boasts an impressive high breaking capacity index-all elegantly packed in a compact device. Our circuit breakers adhere rigorously to the GB 10963 and IEC60898 standards, ensuring unparalleled safety and reliability.

These circuit breakers are a staple for safeguarding contactors, relays, and other electrical equipment from overloads, providing peace of mind in various electrical applications.

Key Functions: Short circuit protection, overload protection, and effective isolation.

Model
DABL-63 1P+N/2P RCBO Circuit Breaker
Rated current Rated frequency Rated operating voltage Rated residual current Rated insulation voltage Impulse withstand voltage Instantaneous trip type Rated breaking capacity W*H*L
6-63A 50-60Hz 230/400V 10,30,100,300A 500V 6KV B/C/D DABL-63 10KA, DABL-63 6KA 36/54mm*80.4mm*72mm
 
DABL-63 3P+N/4P RCBO Circuit Breaker
Rated current Rated frequency Rated operating voltage Rated residual current Rated insulation voltage Impulse withstand voltage Instantaneous trip type Rated breaking capacity W*H*L
6-63A 50-60Hz 230/400V 10,30,100,300A 500V 6KV B/C/D DABL-63 10KA, DABL-63 6KA 72/90mm*80.4mm*72mm
 

Technical Parameter of DABL-40 Electronic Residual Current Circuit Breaker
Protection Grade: IP20
Flame Retardant Grade: Grade 2
Mechanical Endurance: Up to 12,000 operations
Electrical Endurance: Up to 6,000 operations
Compatible Electric Wire: 1~25mm2
Operating Temperature Range: -5~+40ºC
Altitude: ≤2000 meters
Relative Humidity: +20ºC, ≤90%; +40ºC, ≤50%
Pollution Class: 2
Installation Environment: Should avoid significant shock and vibration.
Installation Grade: Grade II, Grade III

Installable Accessories for DABL-63 Electronic Residual Current Circuit Breaker
Available Accessories: Auxiliary contact, alarm contact, shunt trip, undervoltage trip, overvoltage trip

Advantages

· Innovative combination of an electronic module for differential protection and the integrated circuit breaker of the DAB7-63 series.
· Delivers unparalleled protection from electric shock hazards upon direct contact with conducting parts.
· Features an independent contact position indicator for enhanced safety.
· Operates efficiently across a broad temperature range from -25 to +40° С.
· Terminal clamps with notches for reduced thermal losses and enhanced mechanical stability.
· Equipped with a "TEST" button to verify device operation and connection accuracy.
· Compact design with DABL dimensions equivalent to a 2-modular item due to innovative element placement.
· Enhanced 6 kA capacity, ideal for using AVDTs as primary protection switches.
 
RCBO with Residual Leakage Current Protection 3p Circuit Breaker

 
RCBO with Residual Leakage Current Protection 3p Circuit Breaker

 
RCBO with Residual Leakage Current Protection 3p Circuit Breaker
 
RCBO with Residual Leakage Current Protection 3p Circuit Breaker
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

People who viewed this also viewed