Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Manual Type |
Still deciding? Get samples of US$ 299/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Overview
Introducing the Dada DAM3-1600 Molded Case Circuit Breaker, a powerhouse in electrical protection with a rated current capacity soaring up to 1600A. Engineered for the utmost reliability, this versatile device is your go-to solution for safeguarding power distribution circuits operating at a frequency of 50-60Hz with an impressive rated operating current reaching 1000A. Beyond its role as a circuit protector, the DAM3-1600 shines in electric motor applications, expertly handling infrequent starting and offering robust protection against overloads, short circuits, and undervoltage scenarios.
Redefining excellence, the DAM3 series stands out with its compact design, elevated breaking capacity, and enhanced energy efficiency, positioning it a cut above the DAM1 series.
Electrical Parameters of DAM3-1600 Molded Case Circuit BreakerRated current of frame size Inm [A] | 1600 | |||
Rated current [A] | 1000 1250 1600 | |||
Number of poles | 3 / 4 | |||
Rated operating voltage | (AC)50-60HZ [V] | 400/690 | ||
DC [V] | 250/1000 | |||
Rated impulse withstand voltage Uimp [KV] | 8 | |||
Rated insulation voltage Ui[V] | 750 | |||
Test voltage at industrial frequency for 1 min [V] | 3000 | |||
Rated ultimate short-circuit breaking capacity Icu [KA] | S | H | G | |
(AC)50-60HZ 220/230V [KA] | 80 | 105 | 130 | |
(AC)50-60HZ 400/415V [KA] | 55 | 70 | 100 | |
(AC)50-60HZ 690V[KA] | 20 | 25 | 30 | |
(DC)250V-2 Poles in series | 50 | 65 | 80 | |
(DC)500V-2 Poles in series | 22 | 30 | 40 | |
(DC)750V-4 Poles in series | 42 | 55 | 68 | |
(DC)1000V-4 Poles in series | 35 | 45 | 55 | |
Rated service short-circuit breaking capacity, Ics [KA] | ||||
(AC)50-60HZ 220/230V [%Icu] | 60% | 60% | 60% | |
(AC)50-60HZ 400/415V [%Icu] | 60% | 60% | 60% | |
(AC)50-60HZ 690V[%Icu] | 60% | 60% | 60% | |
Category of utilisation(EN 60947-2) | A | |||
Isolation condition | Bitmap | |||
Reference standard | IEC/EN 60947-2/GB 14048.2 | |||
Interchangeability | Bitmap | |||
Versions | Fixed | Bitmap | ||
Plug-in | Bitmap | |||
Draw-out | Bitmap |
Endurance | Total cycles | 5000 |
Electrical endurance | 1000 | |
Mechanical endurance | 4000 | |
Basic dimensjons-fixed version |
3/4 Poies W[mm] | 210/280 |
3/4 Poies H[mm] | 140 | |
H1[mm] | 196 | |
3/4 Poies L[mm] | 328 |
Introduction
The innovative DAM3-1600 Molded Case Circuit Breaker is designed to autonomously interrupt the current flow whenever it surpasses the predefined release setting. Integral to its design, the 'molded case' is a robust plastic insulator that encapsulates the device frame, ensuring the insulation of conductors and safeguarding against metal grounding exposure.
Working Principle
At the heart of the DAM3-1600's operation is a sophisticated mechanism where the main contact is engaged either manually or electrically. Once engaged, a free release mechanism secures it in the closed position. In this state, the overcurrent trip coil, along with the thermal trip element, is serially integrated with the main circuit, while the undervoltage trip coil is strategically aligned in parallel with the power supply.