Cdada 250A Fixed Type Moulded Case Circuit Breaker Low Voltage

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 10/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Cdada 250A Fixed Type Moulded Case Circuit Breaker Low Voltage
  • Cdada 250A Fixed Type Moulded Case Circuit Breaker Low Voltage
  • Cdada 250A Fixed Type Moulded Case Circuit Breaker Low Voltage
  • Cdada 250A Fixed Type Moulded Case Circuit Breaker Low Voltage
  • Cdada 250A Fixed Type Moulded Case Circuit Breaker Low Voltage
  • Cdada 250A Fixed Type Moulded Case Circuit Breaker Low Voltage
Find Similar Products

Basic Info.

Model NO.
CM1-125
Arc-extinguishing Medium
Arc Chamber
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Transport Package
Carton
Specification
12.5, 16, 20, 25, 32, 40, 50, 70, 80, 100A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
85362000
Production Capacity
10000PCS/Month

Product Description

Cdada 250A Fixed Type Moulded Case Circuit Breaker Low Voltage


Embrace the future of electrical safety with the groundbreaking DAM2 series Moulded Case Circuit Breaker, a testament to cutting-edge engineering excellence. Meticulously crafted with state-of-the-art international technology, these circuit breakers boast a sleek, compact design, unparalleled breaking capacity, minimized arc-over distance, and a rugged shake-proof construction. Whether on land or at sea, they stand unrivaled as the quintessential choice for reliable performance in any environment.

Application

The DAM2 (CM1) series circuit breaker is a formidable powerhouse, featuring a rated insulation voltage of 800V. Tailored for AC distribution networks operating at 50Hz/60Hz, it adeptly manages a rated working voltage of up to 690V and a current capacity reaching 1250A. This exceptional device excels in power distribution while proficiently protecting circuits and equipment from overloads, short-circuits, under-voltage, and other potential hazards. It also facilitates occasional circuit conversions and motor starts, offering unmatched versatility in installation-either vertically or horizontally. Capable of serving as an isolator, denoted by the symbol ' ', the DAM2 MCCB proudly adheres to the stringent standards of IEC60947-2 for low-voltage switchgear and control equipment, Part 2: circuit breakers.

Cdada 250A Fixed Type Moulded Case Circuit Breaker Low VoltageCdada 250A Fixed Type Moulded Case Circuit Breaker Low Voltage

Normal Operating Conditions

1. Ambient Air Temperature: Ensure ambient air temperature remains between -5ºC and +40ºC, with an average daily temperature not exceeding +35ºC.
2. Altitude: The installation site should not exceed an altitude of 2000 meters.
3. Atmospheric Conditions: At a peak temperature of +40ºC, the relative humidity should not surpass 50%. Higher humidity is permissible at lower temperatures, with a maximum monthly average relative humidity of 90% at a minimum average temperature of +25ºC, considering the impact of temperature-induced condensation on the product's surface.
4. Pollution Degree: Level 3.

Selection of Instructions

Classified by Pole Types:
Type A: N-pole lacks over-current release components, continuously connected, and operates independently from the other three poles.
Type B: N-pole without over-current release components, functions alongside the other three poles (N-pole activates before deactivation).
Type C: N-pole with over-current release components, operates in tandem with the other three poles (N-pole activates prior to deactivation).

Classified by Rated Current of Over-Current Release:
DAM2-63 MCCB Available in an array of nine ratings: 6, 10, 16, 20, 25, 32, 40, 50, 63 A, precisely catering to a wide spectrum of requirements.
DAM2-100 MCCB Available in nine versatile ratings: 16, 20, 25, 32, 40, 50, 63, 80, 100 A, offering an adaptable solution for diverse applications.
DAM2-250 MCCB Available in seven ratings: 100, 125, 140, 160, 180, 200, 225, 250 A, ensuring comprehensive flexibility for varied needs.
DAM2-400 MCCB Available in five ratings: 225, 250, 315, 350, 400 A, meticulously designed to meet high-performance standards.
DAM2-630 MCCB Available in three robust ratings: 400, 500, 630 A, crafted for those powerful, demanding applications.
DAM2-800 MCCB Available in three robust ratings of 630, 700, and 800 A, our Cdada 250A Fixed Type Moulded Case Circuit Breaker Low Voltage is expertly tailored for your higher capacity needs, ensuring superior performance and reliability.
Discover the DAM2-1250 MCCB, available in three significant ratings: 800, 1000, and 1250 A, engineered for ultimate power and unparalleled protection. Elevate your electrical systems with confidence and durability.
Remark: It is important to note that our 6A version is limited to electromagnetic (instantaneous) type operation. Due to its specification constraints, we do not recommend it for critical applications. Choose wisely to guarantee optimal performance and safety.
Wiring Options: Customize your installation with our extensive selection of wiring choices, including front-of-board, back-of-board, or insertion type. These flexible options ensure seamless and efficient integration into a variety of setups, enhancing your system's adaptability.
Over-Current Release Patterns: Our circuit breakers are meticulously designed in both thermodynamic-electromagnetic (dual) type and electromagnetic (instantaneous) type. They meet diverse application requirements with unparalleled precision and reliability, ensuring peak performance across all scenarios.
Outfit Options: Personalize your circuit breaker to perfectly match your specific requirements by choosing between versions with or without outfit options. This customization ensures the best fit for your unique electrical systems and enhances overall functionality.
Outfit Details: Amplify your circuit breaker's capabilities with our comprehensive range of inner accessories, such as the shunt release, under-voltage release, auxiliary contact, and alarm contact. Opt for outer accessories like turning handle and power-driven operation mechanisms to achieve full control and support.
Breaking Capacity: Choose from our extensive capacity offerings, including L-standard breaking, M-second high breaking, and H-high breaking types. Tailor your selection to perfectly align with the diverse demands of your applications, ensuring exceptional circuit protection at every turn.

Cdada 250A Fixed Type Moulded Case Circuit Breaker Low VoltageCdada 250A Fixed Type Moulded Case Circuit Breaker Low Voltage


Technical Parameters: Gain detailed insights into the sophisticated technical parameters that define our Cdada 250A Fixed Type Moulded Case Circuit Breaker Low Voltage, ensuring a precise and informed selection for your needs.

1. Instantaneous Action Characteristics: Our distribution circuit breakers feature a precise setting value of 10In±20%. The advanced DAM2-1250 model is meticulously configured at 7In±20%, while motor protection circuit breakers are rigorously set to 12In±20%, guaranteeing optimal performance and safety.
2. Rated Values: For a comprehensive understanding of our circuit breaker's rated values, refer to Table 2. You will find detailed specifications that empower you with the knowledge needed for informed decision-making and enhanced system performance.
3. Ambient Temperature: At an ambient temperature of +40ºC, explore the intricate over-current release action characteristics detailed in Table 3 for distribution circuit breakers and Table 4 for motor protection circuit breakers. This ensures robust performance across diverse conditions.

Rated Value: Uncover the intricate specifics of our circuit breaker's rated value, offering a clear picture of its capabilities. This thorough understanding ensures that it aligns perfectly with your application needs, maximizing performance and reliability.

Model Pole Rated current (A) Rated
operating
voltage (V)
Rated
insulation
voltage (V)
Rated ultimate short - circuit breaking capacity (Icu) Flashover
distance(mm)
Test voltage (V) Icu (kA) Ics (kA)
DAM2L-63 3 10,16,20,25,
32,40,50,63
400 500 400×1.10 25 18 0
DAM2M-63 3,4 50 35
DAM2L-100 3,4 16,20,25,32,40,
50,63,80,100
400 800 30 22 ≤50
DAM2M-100 2,3,4 50 35
DAM2H-100 3 85 50
DAM2L-100 3,4 690 10 5
DAM2M-100 2,3,4 20 10
DAM2L-225 3,4 100,125,140,
160,180,200,225
400 800 35 25
TXCM1-225 2,3,4 50 35
DAM2H-225 3 85 50
DAM2L-225 3,4 690 10 5
DAM2M-225 2,3,4 20 10
DAM2L-400 3 225,250,315,
350,400
400 800 50 35 ≤100
DAM2M-400 3,4 65 42
DAM2H-400 3 100 65
DAM2L-400 3 690 15 8
DAM2M-400 3,4 20 10
DAM2L-630 3 400,500,630 400 800 50 35
DAM2M-630 3,4 65 42
DAM2H-630 3 100 65
DAM2L-630 3 6910 15 8
DAM2M-630 3,4 20 10
DAM2M-800 3 630,700,800 400 800 75 50
DAM2H-800 3 100 65
DAM2M-800 3 4690 30 15
DAM2-1250 3 800,1000,1250 400 800 85 42
DAM2-1250 3 690 25 12.5

Note: For our 2-pole and 4-pole circuit breakers categorized into L, M, and H types, you can be confident that the breaking index for all models aligns with the M-type. This consistency ensures reliability and uniformity across our product range.

Inverse Time Breaking Action: Gain a deep understanding of the nuanced over-current release characteristics for power distribution, particularly when all poles are simultaneously energized, providing comprehensive and reliable protection.

No. Test current I/In Set time Initial state
1 Conventional non-tripping current 1.05 2h(In>63A),1h(In≤63A) Cold
2 Conventional non-tripping current 1.30 2h(In>63A),1h(In≤63A) Immediately after Test 1

Instantaneous Action Characteristics: Our distribution circuit breakers are expertly engineered with a setting value of 10In±20%, while motor protection circuit breakers are rigorously set at 12In±20%. This design ensures effective and safe operation, consistently delivering on performance.

Inverse Time Breaking Action: Investigate the intricate characteristics of over-current release for motor protection when all poles are equally energized. This ensures that every aspect of your systems is meticulously protected and tailored for safety.

No. I/In Set time Initial state Remark
1 1.0 >2h Cold  
2 1.2 ≤2h Immediately after Test 1  
3 1.5 ≤4min Cold 10≤n≤225
≤8min 225 < in ≤ 630
4 7.2 4s≤T≤10s Cold 10≤In≤225
6s≤T≤20s 225 < in ≤ 630

Accessories: Explore our range of sophisticated accessories designed to enhance and expand the functionality of your circuit breaker systems, offering comprehensive solutions for your electrical needs.

1. Internal Accessories of Circuit Breakers: Discover the internal accessories available for our circuit breakers, crafted to enhance performance and reliability.

1.1 Shunt Release: Explore the exceptional reliability of our shunt release, designed to operate under a rated control supply voltage for seamless integration into your systems.
Shunt Release Voltage: Experience unparalleled reliability with our shunt release, engineered to perform flawlessly under a rated control supply voltage of AC50Hz, 230V, 400V, and DC110V, 220V, 24V. With dependable performance within a 70%~110% voltage range, your circuit breaker will function seamlessly.

DC24V Shunt Release: To ensure consistent and reliable operation, adhere to specified standards for the maximum length of copper wire. This guarantees that your circuit breaker remains operational and secure, providing peace of mind.

Rated control
supply voltage Uc(DC24V)/Conductor area
1.5mm² 2.5mm²
100%Uc
85%Uc
150m
100m
250m
160m

Design Recommendations: To ensure the utmost in functionality and safety, if the specified table requirements are not fully satisfied, it is crucial to design your shunt release control circuit in accordance with the provided figure. This will guarantee optimal performance and seamless safety integration.

1.2 Under-Voltage Release

Under-Voltage Operation: Experience unwavering reliability with our under-voltage release, engineered to ensure consistent circuit breaker performance. It adeptly operates when supply voltage dips between 70% to 35% of the rated voltage, upholding both safety and operational efficacy.
Under-Voltage Protection: This innovative system provides robust under-voltage protection by preventing the circuit breaker from closing if voltage levels drop below 35% of the rated value. Once voltage surpasses 85%, it enables closure, delivering assured safety and operational dependability.
Closing Mechanism: For enhanced safety, our under-voltage release ensures the circuit breaker closes securely when supply voltages exceed 85% of the rated value, thus optimizing system security.
Under-Voltage Ratings: Our devices boast ratings of AC50Hz, 230V, 400V, guaranteeing consistent performance that meets the pinnacle of safety and reliability standards.
400V.
Special Note: Our circuit breakers, equipped with sophisticated under-voltage releases, are meticulously designed to perform optimally at the specified rated voltage, ensuring safe and effective opening and closing cycles.
normally.

1.3 Pre-Paid Meter Dedicated Release

Our advanced pre-paid meter dedicated release is a marvel of modern engineering, with a rated operating voltage Ue of AC230/50Hz. It delivers exceptional performance across a versatile spectrum of 65% to 110% of Ue. Ingeniously, when the control (Ctrl) is disengaged, the circuit breaker executes a delayed opening, ranging from 0.5 to 2 seconds. This guarantees maximum safety and reliability, allowing you the ultimate peace of mind.

Wiring Diagram for Pre-Paid Meter Dedicated Release: Your comprehensive guide to achieving seamless and efficient connectivity.

1.4 Rated Values of Auxiliary Contacts and Alarm Contacts (Refer to Table 5 for comprehensive details)

Classification Conventional thermal current (Ith) Rated current when

 

AC 400V Ie(AC-15)

Rated current when

 

DC 220V Ie(DC-13)

Auxiliary contact 3 0.4 0.15
Alarm contact 3 0.3 0.15

a. Auxiliary Contact: Designed to boost operational efficiency to new heights.

b. Alarm Contact: Engineered with precision for dependable notifications.
Our expertly crafted alarm contacts are designed to stay inactive during regular operations, shifting between normal open and closed states solely during free or fault tripping. This ensures that precise alerts are activated only when genuinely necessary, enhancing reliability.

2. External Accessories for Circuit Breakers: Elevate functionality and performance to superior levels.

2.1 Motor Operating Mechanism: Discover detailed insights by exploring rated values and their corresponding codes in Table 6.

Category/Model DAM2-63. 125. 250 DAM2-400. 630. 800. 1250
Structure type Electromagnet Motor
AC voltage code AC50Hz,230V,400 AC50Hz,230V,400
DC voltage code DC110V,220V DC110V,220V

NOTE: Following a circuit breaker trip using an electric operating mechanism, a reset is required before re-engagement can occur, ensuring the system is operationally ready.

Principle Diagram for the Opening and Closing of DAM2-63,100,225 Electric Operating Mechanism (AC): Visualize the complete process for an enhanced understanding of operations.

Principle Diagram for Opening and Closing of DAM2-400,630,800,1250 Electric Operating Mechanism (AC): Gain a clear perspective on high-capacity operations.

2.2 Installation Dimensions for Manual Operating Mechanism: Refer to Table 10 to ensure precision installation dimensions that fit perfectly and function seamlessly.
Diagram of Handle Mounting Hole for DAM2-63~800: Your guide to ensuring precise and correct installation.

Total Height of Electric/Manual Operating Mechanism of Circuit Breaker (mm) (Refer to Table 12): Ensure an accurate and flawless integration within your systems.

Model Total height of electric
operating mechanism H
Installation dimensions

 

of manual operating mechanism H

DAM2L-63 155 49
DAM2M/H-63 164 49
DAM2L-100 152 51
DAM2M/H-100 170 51
DAM2L-225 182 54
DAM2M/H-225 199 54
DAM2L/M/H-400 255 88
DAM2M/H-630 262 89
DAM2M/H-800 261 96
DAM2H-1250 290 103

Quick Selection Table for DAM2 Series Molded Case Circuit Breakers: Streamline your decision-making for perfect selection.

Corresponding
letters
Function name Function corresponding to the model
a Model features DAM2 Molded Case

 

Circuit Breaker

b Frame rated current code 63A,100A,225A,

 

400A,630A,800A,

1250A

c Breaking capacity characteristic
code
L-standard breaking type;

 

M-second high breaking type;

H-high breaking type

d Operation mode code No code for handle operation;

 

P for electric operation;

Z for turning handle operation

e Pole 2-two poles;

 

3-three poles;

4-four poles

f Release name 2 Electromagnetic release;

 

3 Double release

g Accessory 00 Without accessory
08 Alarm contact
10 Shunt release
20 Auxiliary contact
30 Undervoltage release
40 Shunt release, Auxiliary contact
50 Shunt release, Undervoltage release
60 Two sets of auxiliary contacts
70 Auxiliary contact, Undervoltage release
18 Shunt release, Alarm contact
28 Auxiliary contact, Alarm contact
38 Undervoltage release, Alarm contact
48 Shunt release, Auxiliary contact, Alarm contact
58 Shunt release, Undervoltage release, Alarm contact
68 Two sets of auxiliary contacts, Alarm contact
78 Auxiliary contact, Undervoltage release, Alarm contact
10Y Pre-paid meter dedicated release
40Y Pre-paid meter dedicated release, Auxiliary contact
50Y Pre-paid meter dedicated release, Auxiliary contact, Undervoltage release
18Y Pre-paid meter dedicated release, Alarm contact
48Y Pre-paid meter dedicated release, Auxiliary contact, Alarm contact
58Y Pre-paid meter dedicated release, Undervoltage release, Alarm contact
h Application No code for distribution;

 

2 for motor protection

i Conventional products No code;

 

T for transparent cover products

j Amperage 10,16,20,25,32,63,80,100,125,160,180,200
,225,250,315,350,400,500,630,700,800,1000
,1250

Example: DAM2L-100 / 33102 63A defines a DAM2-type molded case circuit breaker featuring a frame rated current of 100A. It provides standard breaking capacity, handle operation, 3 poles, double release, and shunt release, expertly crafted for motor protection with a rated current of 63A.
For optimal performance, it is imperative to adhere strictly to the guidelines detailed in our product manual or comply with relevant national standards during the selection, installation, and usage of our products.
Important Notice: In a 4P circuit breaker, the N-pole type can be classified into A-type and B-type. Please note that if no specification is provided, the B-type will be used as the default option.

Working Principle: An in-depth exploration of the sophisticated core mechanism that underpins the operation of our circuit breakers.
The primary contact of the molded case circuit breaker can be effortlessly closed either manually or electrically. Once closed, the innovative free release mechanism ensures that the main contact remains securely locked in the closed position, providing unwavering stability and safety. The over
current trip coil and the precision-engineered thermal trip element are expertly connected in series with the main circuit, providing seamless and sensitive protection.
Voltage
release: A crucial safety feature that guarantees reliable and secure operation.
coil and the power supply are ingeniously connected in parallel, delivering consistent, robust, and trustworthy performance.
Cdada 250A Fixed Type Moulded Case Circuit Breaker Low Voltage

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier